APPROVED
INTERPRETATION GUIDANCE FOR DOE M 232.1-1A |
"Roll-up into an occurrence report for another facility"
Approved 9/27/99
REQUIREMENT
5.7 ROLL-UP OCCURRENCE REPORTS FOR OFF-NORMAL OCCURRENCES
5.7.1 Similar Occurrences Documented in Non-Finalized Occurrence
Report. Roll-Up Reports are permitted when a Final Report has
not been approved for similar occurrences that meet the threshold
requirements of this Manual and are expected to have the same root
cause code (Field #22), the same or similar direct and contributing
causes, and the same or similar corrective actions.
INTERPRETATION
Issue:
An event occurs, such as a minor personnel contamination that is considered
to be a candidate for a Roll-Up Report. However, an existing report
is not in the occurrence reporting system for that facility. How can
that report be identified as a roll-up occurrence? Can that report
be rolled-up into a report at another facility?
Intent:
An occurrence can not be rolled-up into an occurrence report for another
facility.
Additional Information:
If roll-ups were allowed to be from different facility designations,
then the trending and tracking of the information would not be accurate.
There also could be a problem with involving the appropriate Facility
Managers, Facility Representatives, and Program Managers. Some contractors
do have a facility designation that is intended to be for events that
are generic in nature or that have affected several facilities. If
approved by the Facility Representatives and Program Managers, this
method could be one way to effectively utilize the roll-up reporting
option. Minor contaminations and defective items, material, services
are good examples for that kind of reporting. These should be site-wide
generic issues and rolling them up could strengthen capability for
site-wide corrective actions. Carefully consider the factors when
attempting to roll-up events under a generic facility code.
|