Home > Electronic
Reading Room > Document
Collections > NUREG-Series
Publications > Publications
Prepared by NRC Contractors
> NUREG/CR-3493
A Review of the
Limerick Generating Station
Severe Accident Risk Assessment (NUREG/CR-3493)
On this page:
Download complete document
The following links on this page are to documents in Adobe Portable Document
Format (PDF). See our Plugins, Viewers, and
Other Tools page for more information. For successful viewing of PDF documents on our site please be sure to use the latest version of Adobe.
Publication Information
Manuscript Completed: July 1984
Date Published: July 1984
Prepared by
M. A. Azarm, R. A. Bari, J. L. Boccio, N. Hanan,
1. A. Papazoglou, C. Ruger, K. Shiu,
J. Reed*, M. McCann*, A. Kafka**
Department of Nuclear Energy
Brookhaven National Laboratory
Upton, NY 11973
*Jack R. Benjamin Associates, Inc. Boston College
Prepared for
Division of Safety Technology
Office of Nuclear Reactor Regulation
U.S. Nuclear Regulatory Commission
Washington, D.C. 20555
NRC FIN A3393
Availability
Notice
Abstract
A limited review is performed of the Severe Accident Risk Assessment for
the Limerick Generating Station. The review considers the impact on the
core-melt frequency of seismic- and fire-initiating events. An evaluation is
performed of methodologies used for determining the event frequencies and their
impacts on the plant components and structures. Particular attention is given
to uncertainties and critical assumptions. Limited requantification is performed
for selected core-melt accident sequences in order to illustrate sensitivities
of the results to the underlying assumptions.
|