Regulatory ReferencesThis page lists regulatory references concerning the pressurized-water reactor sump performance issue (GSI-191) and boiling-water reactor suction strainer performance. On this page:
Some links on this page are to documents in our Agencywide
Documents Access and Management System (ADAMS), and others are to documents
in Adobe Portable Document Format (PDF). ADAMS documents are provided in either
PDF or Tagged Image File Format (TIFF). To obtain free viewers for displaying
these formats, see our Plugins, Viewers, and
Other Tools page. If you have questions about search techniques or problems
with viewing or printing documents from ADAMS, please contact the Public
Document Room staff. Inspection Guidance
|
Document Number | Description |
---|---|
Bulletin 03-01 | Potential Impact of Debris Blockage on Emergency Sump Recirculation at Pressurized-Water Reactors, June 9, 2003 |
Bulletin 96-03 | Potential Plugging of Emergency Core Cooling Suction Strainers by Debris in Boiling-Water Reactors, May 6, 1996 |
Bulletin 95-02 | Unexpected Clogging of a Residual Heat Removal (RHR) Pump Strainer While Operating in the Suppression Pool Cooling Mode, October 17, 1995 |
Bulletin 93-02 | Debris Plugging of Emergency Core Cooling Suction Strainers, May 11, 1993 |
Bulletin 93-02, Supp. 1 | Debris Plugging of Emergency Core Cooling Suction Strainers, February 18, 1994 |
GL 04-02 | Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors |
Draft GL 04-XX | Proposed Generic Letter, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized Water Reactors, issued for public comments in the Federal Register. Comment period is now closed. Public Comments: |
GL 98-04 | Potential for Degradation of the Emergency Core Cooling System and the Containment Spray System After a Loss-of-Coolant Accident Because of Construction and Protective Coating Deficiencies and Foreign Material in Containment, July 14, 1998 |
GL 97-04 | "Assurance of Sufficient Net Positive Suction Head for Emergency Core Cooling and Containment Heat Removal Pumps," October 7, 1997 |
GL 85-22 | Potential for Loss of Post-LOCA Recirculation Capability Due to Insulation Debris Blockage, December 3, 1985 |
IN 05-26 | Results of Chemical Effects Head Loss Tests in a Simulated PWR
Sump Pool Environment |
IN 97-13 | Deficient Conditions Associated With Protective Coatings at Nuclear Power Plants, March 24, 1997 |
IN 96-59 | Potential Degradation of Post Loss-of-Coolant Recirculation Capability as a Result of Debris, October 30, 1996 |
IN 96-55 | Inadequate Net Positive Suction Head of Emergency Core Cooling and Containment Heat Removal Pumps Under Design Basis Accident Conditions, October 22, 1996 |
IN 96-27 | Potential Clogging of High-Pressure Safety Injection Throttle Valves During Recirculation, May 1, 1996 |
IN 96-10 | Potential Blockage by Debris of Safety System Piping Which Is Not Used During Normal Operation or Tested During Surveillances, February 13, 1996 |
IN 95-47 | Unexpected Opening of a Safety/Relief Valve and Complications Involving Suppression Pool Cooling Strainer Blockage, October 4, 1995 |
IN 95-47, Rev. 1 | Unexpected Opening of a Safety/Relief Valve and Complications Involving Suppression Pool Cooling Strainer Blockage, November 30, 1995 |
IN 95-06 | Potential Blockage of Safety-Related Strainers by Material Brought Inside Containment, January 25, 1995 |
IN 94-57 | Debris in Containment and the Residual Heat Removal System, August 12, 1994 |
IN 93-34 | Potential for Loss of Emergency Cooling Function Due to a Combination of Operational and Post-LOCA Debris in Containment, April 26, 1993 |
IN 93-34, Supp. 1 | Potential for Loss of Emergency Cooling Function Due to a Combination of Operational and Post-LOCA Debris in Containment, May 6, 1993 |
IN 92-85 | Potential Failures of Emergency Core Cooling Systems Caused by Foreign Material Blockage,” December 23, 1992 |
IN 92-71 | Partial Plugging of Suppression Pool Strainers at a Foreign BWR, September 30, 199 |
IN 89-79 | Degraded Coatings and Corrosion of Steel Containment Vessels, December 1, 198 |
IN 89-79, Supp. 1 | Degraded Coatings and Corrosion of Steel Containment Vessels, June 29, 199 |
IN 89-77 | Debris in Containment Emergency Sumps and Incorrect Screen Configurations, November 21, 1989 |
IN 88-28 | Potential for Loss of Post-LOCA Recirculation Capability Due to Insulation Debris Blockage, May 19, 1988 |