File Name |
Date |
Description |
in82056 |
12/30/1982 |
Robertshaw Thermostatic Flow Control Valves |
in82055 |
12/28/1982 |
Seismic Qualification of Westinghouse AR Relay with Latch Attachments
Used in Westinghouse Solid State Protection System |
in82054 |
12/27/1982 |
Westinghouse NBFD Relay Failures in Reactor Protection Systems |
in82053 |
12/22/1982 |
Main Transformer Failures at the North Anna Nuclear Power Station |
in82052 |
12/21/1982 |
Equipment Environmental Qualification Testing Experience - Updating of
Test Summaries Previously Published in IN 81-29 |
in82051 |
12/21/1982 |
Overexposures in PWR Cavities - |
in82050 |
12/20/1982 |
Modification of Solid State AC Undervoltage Relays Type ITE-27 |
in82049 |
12/16/1982 |
Correction for Sample Conditions for Air and Gas Monitoring |
in82048 |
12/03/1982 |
Failures of Agastat CR 0095 Relay Sockets |
in82047 |
11/30/1982 |
Transportation of Type A Quantities of Non-Fissile Radioactive Material |
in82046 |
11/26/1982 |
Defective and Obsolete Combination Padlocks |
in82045 |
11/19/1982 |
PWR Low Temperature Overpressure Protection |
in82044 |
11/18/1982 |
Clarification of Emergency Plan Exercise Requirements |
in82043 |
11/16/1982 |
Deficiencies in LWR Air Filtration/Ventilation Systems |
in82042 |
11/05/1982 |
Defects Observed in Panasonic Model 801 and Model 802 Thermoluminescent
Dosimeters |
in82041 |
10/22/1982 |
Failure of Safety/Relief Valves to Open at a BWR |
in82040 |
09/22/1982 |
Deficiencies in Primary Containment Electrical Penetration Assemblies |
in82038 |
09/22/1982 |
Change in Format and Distribution System for IE Bulletins, Circulars,
and Information Notices |
in82039 |
09/21/1982 |
Service Degradation of Thick Wall Stainless Steel Recirculation System
Piping at a BWR Plant |
in82034r1 |
09/17/1982 |
Welds in Main Control Panels |
in82037 |
09/16/1982 |
Cracking in the Upper Shell to Transition Cone Girth Weld of a Steam Generator
at an Operating PWR |
in82036 |
09/02/1982 |
Respirator Users Warning for Certain 5-Minute Emergency Escape Self-Contained
Breathing Apparatus |
in82035 |
08/25/1982 |
Failure of Three Check Valves on High Pressure Injection Lines to Pass
Flow |
in82034 |
08/20/1982 |
Welds in Main Control Panels |
in82033 |
08/20/1982 |
Control of Radiation Levels in Unrestricted Areas Adjacent to Brachytherapy
Patients |
in82032 |
08/19/1982 |
Contamination of Reactor Coolant System by Organic Cleaning Solvents |
in82027 |
08/05/1982 |
Fuel Rod Degradation Resulting from Baffle Water-Jet Impingement |
in82031 |
07/28/1982 |
Overexposure of Diver During Work in Fuel Storage Pool |
in82030 |
07/26/1982 |
Loss of Thermal Sleeves in Reactor Coolant System Piping at Certain Westinghouse
PWR Power Plants |
in82029 |
07/23/1982 |
Control Rod Drive (CRD) Guide Tube Support Pin Failures at Westinghouse
PWRs |
in82028 |
07/23/1982 |
Hydrogen Explosion while Grinding in the Vicinity of Drained and Open
Reactor Coolant System |
in82026 |
07/22/1982 |
RCIC and HPCI Turbine Exhaust Check Valve Failures |
in82025 |
07/20/1982 |
Failures of Hiller Actuators upon Gradual Loss of Air Pressure |
in82024 |
07/20/1982 |
Water Leaking from Uranium Hexafluoride Overpacks |
in82023 |
07/16/1982 |
Main Steam Isolation Valve (MSIV) Leakage |
in82022 |
07/09/1982 |
Failures in Turbine Exhaust Lines |
in82021 |
06/30/1982 |
Buildup of Enriched Uranium in Effluent Treatment Tanks |
in82020 |
06/28/1982 |
Check Valve Problems - |
in82019 |
06/18/1982 |
Loss of High Head Safety Injection Emergency Boration and Reactor Coolant
Makeup Capability |
in82018 |
06/11/1982 |
Assessment of Intakes of Radioactive Material by Workers |
in82017 |
06/11/1982 |
Overpressurization of Reactor Coolant System |
in82016 |
05/28/1982 |
HPCI/RCIC High Steam Flow Setpoints |
in82015 |
05/28/1982 |
Notification of the Nuclear Regulatory Commission (NRC) |
in82014 |
05/12/1982 |
TMI-1 Steam Generator/Reactor Coolant System Chemistry/Corrosion Problem |
in82013 |
05/10/1982 |
Failures of General Electric Type HFA Relays |
in82012 |
04/21/1982 |
Surveillance of Hydraulic Snubbers |
in82011 |
04/09/1982 |
Potential Inaccuracies in Wide Range Pressure Instruments Used in Westinghouse
Designed Plants |
in82010 |
03/31/1982 |
Following Up Symptomatic Repairs to Assure Resolution of the Problem |
in82009 |
03/31/1982 |
Cracking in Piping of Makeup Coolant Lines at B&W Plants |
in82008 |
03/26/1982 |
Check Valve Failures on Diesel Generator Engine Cooling System |
in82007 |
03/16/1982 |
Inadequate Security Screening Programs |
in82006 |
03/12/1982 |
Failure of Steam Generator Primary Side Manway Closure Studs |
in82005 |
03/10/1982 |
Increasing Frequency of Drug Related Incidents |
in82004 |
03/10/1982 |
Potential Deficiency of Certain Agastat E-7000 Series Time-Delay Relays |
in82003 |
03/04/1982 |
Environmental Tests of Electrical Terminal Blocks |
in82002 |
01/27/1982 |
Westinghouse NBFD Relay Failures in Reactor Protection Systems at Certain
Nuclear Power Plants |
in82001 |
01/22/1982 |
Auxiliary Feedwater Pump Lockout Resulting from Westinghouse W-2 Switch
Circuit Modification |