Index | Site Map | FAQ | Facility Info | Reading Rm | New | Help | Glossary | Contact Us |
Licensee's General Comments: none
Unplanned Scrams per 7000 Critical Hrs | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
Unplanned scrams | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Critical hours | 871.7 | 2208.0 | 2209.0 | 2183.0 | 2184.0 | 2091.3 | 1443.0 | 2159.0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Unplanned Power Changes per 7000 Critical Hrs | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
Unplanned power changes | 0 | 1.0 | 0 | 0 | 0 | 2.0 | 0 | 0 |
Critical hours | 871.7 | 2208.0 | 2209.0 | 2183.0 | 2184.0 | 2091.3 | 1443.0 | 2159.0 |
Indicator value | 0 | 0.9 | 0.9 | 0.9 | 0.8 | 1.6 | 1.8 | 1.8 |
Licensee Comments: none
Unplanned Scrams with Complications | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
Scrams with complications | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
Licensee Comments: none
Safety System Functional Failures (PWR) | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
Safety System Functional Failures | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 1 | 1 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Mitigating Systems Performance Index, Emergency AC Power System | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
UAI (ΔCDF) | 1.10E-07 | 1.10E-07 | 1.40E-07 | 9.10E-08 | 9.10E-08 | 1.30E-07 | 1.20E-07 | 1.70E-07 |
URI (ΔCDF) | 1.30E-09 | 1.30E-09 | 2.10E-07 | 1.60E-07 | 1.60E-07 | 1.60E-07 | 4.20E-07 | 6.30E-07 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | 1.11E-07 | 1.11E-07 | 3.50E-07 | 2.51E-07 | 2.51E-07 | 2.90E-07 | 5.40E-07 | 8.00E-07 |
Licensee Comments: none
Mitigating Systems Performance Index, High Pressure Injection System | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
UAI (ΔCDF) | 1.10E-07 | 1.10E-07 | 4.50E-08 | 1.40E-07 | 1.10E-07 | 1.00E-07 | 1.40E-07 | 1.80E-07 |
URI (ΔCDF) | -1.10E-07 | -1.10E-07 | -1.10E-07 | -1.10E-07 | -1.10E-07 | -1.10E-07 | -1.10E-07 | -1.10E-07 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | 0.00E+00 | 0.00E+00 | -6.50E-08 | 3.00E-08 | 0.00E+00 | -1.00E-08 | 3.00E-08 | 7.00E-08 |
Licensee Comments: none
Mitigating Systems Performance Index, Heat Removal System | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
UAI (ΔCDF) | -2.70E-09 | -3.10E-09 | -1.20E-08 | -1.20E-08 | -1.20E-08 | -1.20E-08 | -1.20E-08 | -3.10E-08 |
URI (ΔCDF) | 6.10E-08 | 6.10E-08 | -7.10E-08 | -7.10E-08 | -7.10E-08 | -7.10E-08 | -7.10E-08 | -1.20E-07 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | 5.83E-08 | 5.79E-08 | -8.30E-08 | -8.30E-08 | -8.30E-08 | -8.30E-08 | -8.30E-08 | -1.51E-07 |
Licensee Comments: none
Mitigating Systems Performance Index, Residual Heat Removal System | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
UAI (ΔCDF) | 4.20E-10 | 3.90E-10 | 2.90E-12 | 2.20E-12 | 4.20E-11 | 2.90E-10 | 1.00E-09 | 1.40E-09 |
URI (ΔCDF) | -2.50E-09 | -2.50E-09 | -2.50E-09 | -2.50E-09 | -2.50E-09 | -2.50E-09 | -2.50E-09 | -2.50E-09 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -2.08E-09 | -2.11E-09 | -2.50E-09 | -2.50E-09 | -2.46E-09 | -2.21E-09 | -1.50E-09 | -1.10E-09 |
Licensee Comments: none
Mitigating Systems Performance Index, Cooling Water Systems | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
UAI (ΔCDF) | -1.40E-07 | -1.90E-07 | -1.90E-07 | -7.50E-08 | -7.20E-08 | 6.40E-08 | 8.20E-08 | 1.30E-07 |
URI (ΔCDF) | -3.10E-09 | -4.00E-09 | -4.00E-09 | -1.00E-08 | -1.00E-08 | -1.00E-08 | -1.00E-08 | -1.00E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -1.43E-07 | -1.94E-07 | -1.94E-07 | -8.50E-08 | -8.20E-08 | 5.40E-08 | 7.20E-08 | 1.20E-07 |
Licensee Comments: none
Reactor Coolant System Activity | 4/07 | 5/07 | 6/07 | 7/07 | 8/07 | 9/07 | 10/07 | 11/07 | 12/07 | 1/08 | 2/08 | 3/08 |
Maximum activity | N/A | N/A | 0.000210 | 0.000402 | 0.000358 | 0.000193 | 0.000314 | 0.000382 | 0.000290 | 0.000299 | 0.000309 | 0.000341 |
Technical specification limit | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
Indicator value | N/A | N/A | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Reactor Coolant System Activity | 4/08 | 5/08 | 6/08 | 7/08 | 8/08 | 9/08 | 10/08 | 11/08 | 12/08 | 1/09 | 2/09 | 3/09 |
Maximum activity | 0.000356 | 0.000414 | 0.000347 | 0.000362 | 0.000356 | 0.000400 | 0.000610 | 0.000140 | 0.000250 | 0.000252 | 0.000273 | 0.000277 |
Technical specification limit | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0.1 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Reactor Coolant System Leakage | 4/07 | 5/07 | 6/07 | 7/07 | 8/07 | 9/07 | 10/07 | 11/07 | 12/07 | 1/08 | 2/08 | 3/08 |
Maximum leakage | 0 | 0.103 | 0.036 | 0.050 | 0.120 | 0.020 | 0.030 | 0.045 | 0.004 | 0.030 | 0.088 | 0.024 |
Technical specification limit | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 |
Indicator value | 0 | 1.0 | 0.4 | 0.5 | 1.2 | 0.2 | 0.3 | 0.5 | 0 | 0.3 | 0.9 | 0.2 |
Reactor Coolant System Leakage | 4/08 | 5/08 | 6/08 | 7/08 | 8/08 | 9/08 | 10/08 | 11/08 | 12/08 | 1/09 | 2/09 | 3/09 |
Maximum leakage | 0.005 | 0.030 | 0.050 | 0.020 | 0.030 | 0.070 | 0.060 | 0.060 | 0.070 | 0.060 | 0.060 | 0.010 |
Technical specification limit | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 |
Indicator value | 0.1 | 0.3 | 0.5 | 0.2 | 0.3 | 0.7 | 0.6 | 0.6 | 0.7 | 0.6 | 0.6 | 0.1 |
Licensee Comments: none
Drill/Exercise Performance | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
Successful opportunities | 38.0 | 88.0 | 2.0 | 68.0 | 48.0 | 68.0 | 16.0 | 39.0 |
Total opportunities | 39.0 | 90.0 | 2.0 | 72.0 | 51.0 | 69.0 | 17.0 | 39.0 |
Indicator value | 95.5% | 96.1% | 96.2% | 96.1% | 95.8% | 96.9% | 96.7% | 96.8% |
Licensee Comments: none
ERO Drill Participation | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
Participating Key personnel | 101.0 | 98.0 | 97.0 | 101.0 | 96.0 | 97.0 | 103.0 | 99.0 |
Total Key personnel | 102.0 | 99.0 | 98.0 | 101.0 | 98.0 | 97.0 | 103.0 | 103.0 |
Indicator value | 99.0% | 99.0% | 99.0% | 100.0% | 98.0% | 100.0% | 100.0% | 96.1% |
Licensee Comments:
4Q/08: Correction made to ERO Drill Participation data from participating and total key personnel for month of Dec from 105 to 103.
Alert & Notification System | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
Successful siren-tests | 627 | 714 | 719 | 629 | 719 | 627 | 720 | 626 |
Total sirens-tests | 630 | 720 | 720 | 630 | 720 | 630 | 720 | 630 |
Indicator value | 99.8% | 99.6% | 99.6% | 99.6% | 99.7% | 99.8% | 99.8% | 99.7% |
Licensee Comments: none
Occupational Exposure Control Effectiveness | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
High radiation area occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Very high radiation area occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Unintended exposure occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
RETS/ODCM Radiological Effluent | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
RETS/ODCM occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Action Matrix Summary | Inspection Findings Summary | PI Summary | Reactor Oversight Process
Last Modified: May 1, 2009