Licensee's General Comments: none
Unplanned Scrams per 7000 Critical Hrs | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
Unplanned scrams | 1.0 | 0 | 0 | 0 | 0 | 0 | 0 | 1.0 |
Critical hours | 2136.5 | 2208.0 | 1556.4 | 2183.0 | 2184.0 | 2208.0 | 2209.0 | 2130.0 |
Indicator value | 1.6 | 1.6 | 1.8 | 0.9 | 0 | 0 | 0 | 0.8 |
Licensee Comments: none
Unplanned Power Changes per 7000 Critical Hrs | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
Unplanned power changes | 0 | 1.0 | 0 | 1.0 | 1.0 | 0 | 0 | 0 |
Critical hours | 2136.5 | 2208.0 | 1556.4 | 2183.0 | 2184.0 | 2208.0 | 2209.0 | 2130.0 |
Indicator value | 1.6 | 0.8 | 0.9 | 1.7 | 2.6 | 1.7 | 1.6 | 0.8 |
Licensee Comments: none
Unplanned Scrams with Complications | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
Scrams with complications | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
Licensee Comments: none
Safety System Functional Failures (BWR) | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
Safety System Functional Failures | 0 | 1 | 0 | 0 | 0 | 0 | 2 | 0 |
Indicator value | 0 | 1 | 1 | 1 | 1 | 0 | 2 | 2 |
Licensee Comments:
4Q/08: LER 2008-003 was submitted in December. The LER included report of a SSFF, specifically a Nuclear Measurement Analysis and Control (NUMAC) drawer failure in the HPCI steam leak detection system. A correction has been entered for October 2008 to reflect a SSFF reported by LER 2008-002 submitted on October 17, 2008.
Mitigating Systems Performance Index, Emergency AC Power System | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
UAI (ΔCDF) | -5.70E-08 | -2.50E-07 | -1.20E-07 | -1.10E-07 | -1.10E-07 | -1.40E-07 | -1.40E-07 | -1.70E-08 |
URI (ΔCDF) | -4.10E-06 | -4.00E-06 | -1.60E-06 | -1.60E-06 | -1.50E-06 | -1.50E-06 | -1.50E-06 | -3.30E-07 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -4.16E-06 | -4.25E-06 | -1.72E-06 | -1.71E-06 | -1.61E-06 | -1.64E-06 | -1.64E-06 | -3.47E-07 |
Licensee Comments: none
Mitigating Systems Performance Index, High Pressure Injection System | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
UAI (ΔCDF) | -5.10E-07 | -3.30E-07 | -1.40E-07 | -1.40E-07 | -1.40E-07 | -1.60E-07 | -1.50E-07 | -2.00E-08 |
URI (ΔCDF) | -1.00E-06 | -6.70E-07 | -2.90E-07 | -2.50E-07 | -3.00E-07 | -2.70E-07 | -2.70E-07 | -5.20E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -1.51E-06 | -1.00E-06 | -4.30E-07 | -3.90E-07 | -4.40E-07 | -4.30E-07 | -4.20E-07 | -7.20E-08 |
Licensee Comments: none
Mitigating Systems Performance Index, Heat Removal System | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
UAI (ΔCDF) | -7.70E-08 | -4.40E-08 | -2.00E-08 | -2.00E-08 | -2.10E-08 | -2.10E-08 | -2.10E-08 | -5.40E-09 |
URI (ΔCDF) | 4.70E-07 | 4.70E-07 | 1.80E-07 | 2.00E-07 | 2.00E-07 | 2.10E-07 | 2.00E-07 | 7.60E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | 3.93E-07 | 4.26E-07 | 1.60E-07 | 1.80E-07 | 1.79E-07 | 1.89E-07 | 1.79E-07 | 7.06E-08 |
Licensee Comments: none
Mitigating Systems Performance Index, Residual Heat Removal System | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
UAI (ΔCDF) | -2.10E-07 | -2.10E-07 | -8.40E-08 | -8.40E-08 | -9.00E-08 | -9.00E-08 | -9.90E-08 | -1.10E-08 |
URI (ΔCDF) | -9.10E-07 | -9.10E-07 | -3.70E-07 | -3.50E-07 | -3.40E-07 | -3.40E-07 | -3.30E-07 | -7.80E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -1.12E-06 | -1.12E-06 | -4.54E-07 | -4.34E-07 | -4.30E-07 | -4.30E-07 | -4.29E-07 | -8.90E-08 |
Licensee Comments: none
Mitigating Systems Performance Index, Cooling Water Systems | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
UAI (ΔCDF) | 1.60E-07 | 6.60E-07 | 4.90E-07 | 5.60E-07 | 5.20E-07 | 4.70E-07 | 3.70E-07 | -3.40E-08 |
URI (ΔCDF) | -5.60E-07 | -7.00E-07 | -2.90E-07 | -3.00E-07 | -2.90E-07 | -3.00E-07 | -3.00E-07 | -1.20E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -4.00E-07 | -4.00E-08 | 2.00E-07 | 2.60E-07 | 2.30E-07 | 1.70E-07 | 7.00E-08 | -4.60E-08 |
Licensee Comments: none
Reactor Coolant System Activity | 4/07 | 5/07 | 6/07 | 7/07 | 8/07 | 9/07 | 10/07 | 11/07 | 12/07 | 1/08 | 2/08 | 3/08 |
Maximum activity | 0.000083 | 0.000055 | 0.000406 | 0.000094 | 0.000064 | 0.000074 | 0.000143 | 0.000069 | 0.000101 | 0.000068 | 0.000061 | 0.000074 |
Technical specification limit | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 |
Indicator value | 0 | 0 | 0.2 | 0 | 0 | 0 | 0.1 | 0 | 0.1 | 0 | 0 | 0 |
Reactor Coolant System Activity | 4/08 | 5/08 | 6/08 | 7/08 | 8/08 | 9/08 | 10/08 | 11/08 | 12/08 | 1/09 | 2/09 | 3/09 |
Maximum activity | 0.000075 | 0.000116 | 0.000076 | 0.000403 | 0.000087 | 0.000076 | 0.000570 | 0.000076 | 0.000133 | 0.000733 | 0.000738 | 0.000092 |
Technical specification limit | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 |
Indicator value | 0 | 0.1 | 0 | 0.2 | 0 | 0 | 0.3 | 0 | 0.1 | 0.4 | 0.4 | 0 |
Licensee Comments: none
Reactor Coolant System Leakage | 4/07 | 5/07 | 6/07 | 7/07 | 8/07 | 9/07 | 10/07 | 11/07 | 12/07 | 1/08 | 2/08 | 3/08 |
Maximum leakage | 2.327 | 2.240 | 2.300 | 2.287 | 2.277 | 2.360 | 2.360 | 1.870 | 2.010 | 1.990 | 1.890 | 1.800 |
Technical specification limit | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 |
Indicator value | 9.3 | 9.0 | 9.2 | 9.1 | 9.1 | 9.4 | 9.4 | 7.5 | 8.0 | 8.0 | 7.6 | 7.2 |
Reactor Coolant System Leakage | 4/08 | 5/08 | 6/08 | 7/08 | 8/08 | 9/08 | 10/08 | 11/08 | 12/08 | 1/09 | 2/09 | 3/09 |
Maximum leakage | 1.820 | 1.900 | 1.880 | 2.100 | 2.310 | 1.950 | 1.900 | 1.940 | 1.910 | 2.190 | 1.900 | 2.116 |
Technical specification limit | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 | 25.0 |
Indicator value | 7.3 | 7.6 | 7.5 | 8.4 | 9.2 | 7.8 | 7.6 | 7.8 | 7.6 | 8.8 | 7.6 | 8.5 |
Licensee Comments: none
Drill/Exercise Performance | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
Successful opportunities | 20.0 | 50.0 | 56.0 | 32.0 | 35.0 | 65.0 | 72.0 | 35.0 |
Total opportunities | 20.0 | 52.0 | 58.0 | 34.0 | 36.0 | 70.0 | 74.0 | 36.0 |
Indicator value | 97.7% | 97.4% | 97.6% | 97.0% | 97.3% | 96.1% | 96.2% | 96.1% |
Licensee Comments: none
ERO Drill Participation | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
Participating Key personnel | 113.0 | 113.0 | 115.0 | 109.0 | 109.0 | 120.0 | 123.0 | 124.0 |
Total Key personnel | 116.0 | 118.0 | 115.0 | 111.0 | 116.0 | 121.0 | 123.0 | 124.0 |
Indicator value | 97.4% | 95.8% | 100.0% | 98.2% | 94.0% | 99.2% | 100.0% | 100.0% |
Licensee Comments: none
Alert & Notification System | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
Successful siren-tests | 497 | 496 | 497 | 497 | 497 | 497 | 497 | 497 |
Total sirens-tests | 497 | 497 | 497 | 497 | 497 | 497 | 497 | 497 |
Indicator value | 99.3% | 99.9% | 99.9% | 99.9% | 99.9% | 100.0% | 100.0% | 100.0% |
Licensee Comments: none
Occupational Exposure Control Effectiveness | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
High radiation area occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Very high radiation area occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Unintended exposure occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
RETS/ODCM Radiological Effluent | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 | 4Q/08 | 1Q/09 |
RETS/ODCM occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Action Matrix Summary |
Inspection Findings Summary |
PI Summary |
Reactor Oversight Process