NIOSH Respirator User Notice

May 2, 1997

This notice is the first update of the NIOSH Guide to the Selection and Use of Particulate Respirators Certified under 42 CFR part 84 (NIOSH No. 96-101) published in January 1996. It modifies the NIOSH service time recommendations for P-series particulate respirators.

The Guide provided that, "Use and reuse of the P-series filters would be subject only to considerations of hygiene, damage, and increased breathing resistance." The Guide also stated that "NIOSH will be conducting and encouraging other researchers to conduct studies to assure that these service time recommendations are adequate. If research indicates the need, additional service time limitations may be recommended by NIOSH for specific workplace conditions."

Recent NIOSH laboratory studies indicate the efficiency of P-series filters may be significantly reduced with long term use in the presence of oil aerosols. Such long term oil exposure has resulted in the reduction in efficiency of P100 filters to efficiencies much less than that required of P95 filters. In some workplace situations, this reduction in filter efficiency may not always be accompanied by an increase in breathing resistance that would signal the user to replace the filter, or filter element. This reduction in filter efficiency varies significantly from model to model and NIOSH can not make a single filter change recommendation that is appropriate for all models. Therefore, NIOSH has requested each manufacturer of P-series filters to establish service time recommendations as part of their user instructions. NIOSH expects that manufacturers of P-series filters will provide such recommendations as part of their customer support programs.

These NIOSH recommendations are interim in that a full understanding of the degrading effects of workplace contaminants on filter efficiency is not yet available to NIOSH. In addition to continuing to study the degrading effects of workplace aerosols on all types of filters certified under 42 CFR part 84, NIOSH is also investigating the possible degrading effects of workplace gases and vapors on those filters.

Respirator users are also reminded that the provisions of the new 42 CFR part 84 require respirators to be far more resistant to filter degradation than did the provisions of 30 CFR part 11. That is only one of the reasons why NIOSH encourages users to discontinue the use of particulate respirators certified under 30 CFR part 11 and switch to the new particulate respirators certified under 42 CFR part 84.

Users are also reminded that NIOSH has a long standing recommendation that all 30 CFR part 11 particulate filters be replaced at least daily (once each work shift).

This User Notice does not change the NIOSH service time recommendations made in the Guide for N- and R- series respirators.

The current NIOSH service-time-limit recommendations for nonpowered particulate filter respirators are that filter elements should be replaced at the following frequencies: