[Code of Federal Regulations]
[Title 46, Volume 4]
[Revised as of October 1, 2002]
From the U.S. Government Printing Office via GPO Access
[CITE: 46CFR111.15-30]

[Page 224]
 
                           TITLE 46--SHIPPING
 
    CHAPTER I--COAST GUARD, DEPARTMENT OF TRANSPORTATION (CONTINUED)
 
PART 111--ELECTRIC SYSTEMS--GENERAL REQUIREMENTS--Table of Contents
 
Subpart 111.15--Storage Batteries and Battery Chargers: Construction and 
                              Installation
 
Sec. 111.15-30  Battery chargers.

    Each battery charger enclosure must meet Sec. 111.01-9. 
Additionally, each charger must be suitable for the size and type of 
battery installation that it serves. Chargers incorporating grounded 
autotransformers must not be used. Except for rectifiers, chargers with 
a voltage exceeding 20 percent of the line voltage must be provided with 
automatic protection against reversal of current.

[CGD 94-108, 61 FR 28278, June 4, 1996; 61 FR 36787, July 12, 1996]