[Code of Federal Regulations] [Title 46, Volume 4] [Revised as of October 1, 2002] From the U.S. Government Printing Office via GPO Access [CITE: 46CFR128.410] [Page 437] TITLE 46--SHIPPING CHAPTER I--COAST GUARD, DEPARTMENT OF TRANSPORTATION (CONTINUED) PART 128--MARINE ENGINEERING: EQUIPMENT AND SYSTEMS--Table of Contents Subpart D--Design Requirements for Specific Systems Sec. 128.410 Ship's service refrigeration systems. No self-contained unit either for air-conditioning or for refrigerated spaces for ship's stores need comply with Sec. 58.20-5, 58.20-10, 58.20-15, 58.20-20(a), or 58.20-20(b) of this chapter if-- (a) The unit uses a fluorocarbon refrigerant allowed by part 147 of this chapter; (b) The manufacturer certifies that the unit is suitable for its intended purpose; and (c) Electrical wiring meets the applicable requirements in subchapter J of this chapter.