Accident Info-Gram
September 2007

Meter Test Leads Short While Testing Contactor

An electrical near-miss accident occurred on September 29, 2007, at an underground mine in District 8. This accident occurred as a repairman was correcting a problem on a continuous mining machine. The previous shift reported that the left-hand conveyor motor was pulling 20-amps more than the right-hand conveyor motor. The repairman locked and tagged-out the continuous mining machine. He examined the conveyor motor leads inside the controller and found evidence of heating. After tightening the connection on the contactor, the repairman decided to check the voltage on the conveyor-motor line starter and scrubber-motor line starter for voltage drops. The repairman energized the continuous miner and used a Triplett 310 Meter, rated at 1200 volts, to test phase-to-ground voltage on top of the conveyor-motor contactor. He then tried to test A-phase on the scrubber contactor and his meter showed no voltage. The repairman noticed that the red test lead on the meter had unintentionally disconnected from the meter, and he reconnected it. He then tested between the A-phase and the B-phase on the line starter. When he made this test, a phase-to-phase fault occurred between the tips of his meter test leads. The tips of the meter test leads melted, and an electrical arc occurred. The repairman was wearing gloves and was sent to the hospital for observation. He sustained no injuries in this near miss accident.
       New style vacuum contactors are now used in the continuous mining machine’s controller, instead of the older style air contactors. The vacuum contactors have decreased physical separation between phase-lead connectors. This resulted in the meter test lead tips shorting the two phase conductors.

Contactors

BEST PRACTICES

    Test and trouble shoot energized circuits only when necessary.

    When testing and trouble shooting energized circuits:

  • Only make voltage readings phase-to-ground
  • Wear gloves and protective clothing
  • Pay close attention to the placement of meter test leads

Return to Close Call/Info-Gram Index Page

District 8 Home Page

This file was last updated on 11/06/2007

This information was provided by concerned miners in an effort to eliminate accidents. Accident or "close call" information within District 8 may be shared by contacting the MSHA office at (812) 882-7617.




Back to Top   Back to Top www.msha.gov www.dol.gov

Frequently Asked Questions | Freedom of Information Act | Customer Survey
Accessibility | Privacy & Security Statement | Disclaimers

Mine Safety and Health Administration (MSHA)
1100 Wilson Boulevard, 21st Floor
Arlington, VA 22209-3939
Phone:    (202) 693-9400
Fax-on-demand: (202) 693-9401
Technical (web) questions: Webmaster
On-line Filing Help: MSHAhelpdesk@dol.gov
or call (877) 778-6055

Contact Us