www.OSHA.gov | |
Standard Interpretations
05/27/1986 - Safeguarding of power press brakes and a definition of "Safe Distance". |
![]() |
Standard Number: | 1910.212 |
May 27, 1986 Mr. Donald Cejer TRIAD Controls Inc. RD. No. 1, Box 353B Hookstown Grade Road Clinton, Pennsylvania 15026 Dear Mr. Cejer: This is in response to your letter to Mr. Dick Bradley and confirms a telephone discussion with Mr. Bode, a member of my staff. Your letter addressed the safeguarding of power press brakes and requests a definition of "Safe Distance". As you are aware, the Occupational Safety and Health Administration (OSHA) requires that power press brakes be safe-guarded per 29 CFR 1910.212(a), copy enclosed. Point of operation safeguarding must comply with 29 CFR 1910.212(a)(3)(ii). OSHA generally accepts the safeguarding specifications delineated by the American National Standards Institute, Inc. (ANSI) for power press brakes as being the appropriate standard. The current standard is ANSI B11.3-1982. Under the requirements of ANSI B11.3-1982, an employer may use the concept of a safe distance only when safeguarding cannot be achieved with a point of operation guard or device, per Section 6.1.4(1). Additionally, the material position gage (back stop) is also required to be used during all such procedures. Although the ANSI standard committee could not agree upon a dimension for safe distance, OSHA has established a value for it. Safe distance is the distance from the lower die to the edge of the material. Safe distance may not be less than the measured distance on the operator's hand from the juncture of the thumb and hand to the tip of the longest finger plus 1 inch, but not less than 6 inches. [This document was edited on 9/26/2002 to strike information that no longer reflects current OSHA policy. Please see the 2/14/97 Directive CPL 02-01-025 "Guidelines for Point of Operation Guarding of Power Press Brakes" for the current OSHA policy.] If we may be of further assistance, please contact us. Sincerely, John B. Miles, Jr., Director [Directorate of Enforcement Programs] Enclosures [Corrected 6/2/2005] October 15, 1985 U.S. Dept. of Labor OSHA 5360 Genesee Street Bowmansville, NY 14026 Attn: Mr. Dick Bradley, Area Director Subject: Point of Operation Guarding for Power Press, Brakes Dear Mr. Bradley: I, along with other members of the safeguarding community are of the understanding that power press brakes must be guarded under the requirement of 1910.212 of the Federal Standards. However, in recent months several of my industrial accounts have commented about an OSHA directive accepting "Safe Distance" as an alternative to to point of operation guarding. Others have also indicated that citations were issuedon press brakes that were not being used at the time of the OSHA inspection. The owners considered these press brakes to be in compliance and will not equip them with point of operation guarding. In order to avoid misinterpreting the directive or misleading our customers, I would appreciate a written clarification of OSHA's current position on press brake guarding which should clarify when a "Safe Distance" is determined, and what is a "Safe Distance". A copy of the directive would also be helpful. Thank you in advance for your prompt response. Sincerely, Ronald Cejer |
![]() |
![]() |
www.osha.gov | www.dol.gov |
Contact Us | Freedom of Information Act | Customer Survey Privacy and Security Statement | Disclaimers |
||
Occupational Safety & Health Administration 200 Constitution Avenue, NW Washington, DC 20210 |