Table 5.12 – Multiple Single User Toilet Rooms Current Guidelines: Final Revised Guidelines: 4.1.3 Accessible Buildings: New Construction. Accessible buildings and facilities shall meet the following minimum requirements: . . .  (11) Toilet Facilities. If toilet rooms are provided, then each public and common use toilet room shall comply with 4.22. . . . 213.2 Toilet and Bathing Rooms. Where toilet rooms are provided, each toilet room shall comply with 603. . . . Exceptions: . . .  4. Where multiple single user toilet rooms are clustered at a single location, no more than 50 percent of the single user toilet rooms for each use at each cluster shall be required to comply with 603. Model Codes & Standards IBC 2000: Section 1108.2 has a similar exception for multiple single user toilet rooms clustered at a single location. IBC 2003: Section 1109.2 has a similar exception for multiple single user toilet rooms clustered at a single location.