Tamping burner hood showing employee work
location, perforated plate 40%, screen and slot, and taper take-off. Side
view of employee reaching over belly bar for battery at tamping burner hood
location. Note: 3" Maximum distance for belly bar. Must
consider ergonomic problems which may occur if employee must lift batteries
from a further distance.
Design Criteria:
Q = 650 x L cfm
Vslot = 2,000 fpm
Vtransport³ 4,200 - 4,500 fpm
he = 2.2 VPduct
Note: 3" maximum distance for belly bar. Must consider ergonomic problems which may occur if employee must lift batteries from a further
distance.