Chemical Sampling Information |
|
Diuron |
|
General Description
Synonyms: 3-(3,4-Dichlorophenyl)-1,1-dimethylurea; Diurex®; Karmex®
OSHA IMIS Code Number: 2684
Chemical Abstracts Service (CAS) Registry Number: 330-54-1
NIOSH, Registry of Toxic Effects (RTECS) Identification Number: YS8925000
NIOSH Pocket Guide to Chemical Hazards, Diuron: chemical description, physical properties, potentially hazardous incompatibilities, and more
Exposure Limits
American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value (TLV): 10 mg/m3 TWA; Appendix A4 - Not Classifiable as a Human Carcinogen
National Institute for Occupational Safety and Health (NIOSH) Recommended Exposure Limit (REL): 10 mg/m3 TWA
Health Factors
Potential symptoms: Irritation of eyes, skin, nose, throat; in animals: anemia, methemoglobinemia
Health Effects: Irritation-Eyes-Nose, Throat---Mild (HE16)
Affected organs: Eyes, skin, respiratory system, blood
Notes:
- Diuron is an herbicide that inhibits photosynthesis and is considered to have low toxicity in mammals.
- OSHA does not have a PEL for diuron. 3. EPA’s oral reference dose (daily oral exposure likely to be without an appreciable risk of deleterious effects during a lifetime) of diuron is 0.002 mg/kg/day.
- Blood and urinary metabolites identified in a human diuron overdose case included 1-(3,4-diphenyl)-3-methylurea and 1-(3,4-dichlorophenyl)urea.
Date Last Revised: 01/20/2006
Literature Basis:
- NIOSH Pocket Guide to Chemical Hazards: Diuron.
- U.S. EPA Integrated Risk Information System: Diuron (CASRN 330-54-1).
- Pohanish, R.P. (editor): Diuron. In, Sittig’s Handbook of Toxic and Hazardous Chemicals and Carcinogens, Fourth Ed., Vol. 1. Norwich, NY: Noyes Publications, William Andrew Publishing, 2002, pp. 996-998.
- Van Boven, M., Laruelle, L. and Daenens, P.: HPLC analysis of diuron and metabolites in blood and urine. J. Anal. Toxicol. 14(4): 231-234, 1990.
Monitoring Methods used by OSHA
Laboratory Sampling/Analytical Method:
-
sampling media: OSHA Versatile Sampler (OVS-2) - 13 mm XAD-2 tube (270/140 mg sections, 20/60 mesh) with Glass Fiber Filter enclosed
analytical solvent: Acetonitrile
maximum volume: 60 Liters maximum flow rate: 1.0 L/min
current analytical method: High Performance Liquid Chromatography; HPLC/UV
method reference: OSHA Analytical Method (OSHA PV2097)
method classification: Partially Validated
note: Protect the samples from light.