skip navigational links Occupational Safety & Health Administration DOL.gov OSHA.gov DOL.gov
www.OSHA.gov
Chemical Sampling Information
o-Dianisidine
 Field Definitions
 Analytical Methods
General Description

NAME: o-Dianisidine

SYNONYM(s): 3,3'-Dimethoxybenzidine

IMIS: 0873

CAS: 119-90-4

NIOSH: RTECS DD0875000; 14665

Exposure Limits


Health Factors

IARC: Group 2B, possibly carcinogenic to humans

Monitoring

PRIMARY SAMPLING/ANALYTICAL METHOD (SLC1):



MEDIA: Coated Glass Fiber Filters (37 mm) in 3 piece cassette. Coating is Sulfuric Acid.
MAX V: 100 Liters   MAX F: 1.0 L/min
ANL 1: Gas Chromatography; GC/ECD
REF: 2 (OSHA 71)
SAE: 0.13
CLASS: Fully Validated
NOTE: Within ten hours after sampling, transfer filter to glass vial containing 2 mL deionized water. Sample must be shipped and stored at 0 deg C or colder.Analyze as soon as possible. Filters may be obtained by OSHA personnel from SLTC.

COND: C18 column; 55% methanol 45% water; 1 mL/min; UV det: 313, 280; Fluor. Exc. 267; Em 389; Retention time, 14 min; DL 5 ng/inj.; C/P DBA

WIPE:

Yes, with Glass Fiber Filter.

BULK METHOD:

Limit the amount of bulk submitted to one gram or one mL.


Revision Date: 08/24/1992
* All Trademarks are the property of their respective owners.