Previous Years > 1987
December
- [12/30/1987] Rollover protective structures for material handling equipment.[1926.1000]
- [12/22/1987] Requirement for pump jack scaffolds.[1926.452(j)(7)]
- [12/11/1987] Clarification of requirements for 40 hours of training.; Site specific training is required for employees who receive general training.[1910.1200; 1910.120(e)(2)]
- [12/07/1987] Hearing conservation programs and "ear blasts" on communication headsets[1910.95]
- [12/07/1987] Coverage of wood dust under the Hazard Communication Standard (HCS)[1910.1200]
- [11/23/1987] Standards applicable to the process of wrapping meat in plastic.[1910.1200]
- [11/23/1987] The potential hazards associated with the use of horizontal lifelines affixed to two-point suspension (Type T) powered platforms.[1910.66]
- [11/20/1987] Applicability of the revised Hazard Communication Standard to the grain industry.[1910.1200]
- [11/20/1987] Reduction of noise exposure for metal spray operations.[1910.95]
- [11/18/1987] The applicability of General Industry Standards to sign posting operations.[1910.12]
- [11/02/1987] Need to supply a material safety data sheet for oil lubricated compressors.[1910.1200]
- [11/02/1987] Acceptable guarding for continuous cycling boneless meat tenderizers.[1910.212(a)(1); 1910.212(a)(3)(ii)]
- [10/30/1987] Response to a request regarding remedies for airborne pollutants.[1910 Subpart Z]
- [10/28/1987] Work Platforms suspended from Lattice or Hydraulic Crane Booms.[1926.550]
- [10/28/1987] Request for a variance from 1910.106.[1910.106]
- [10/26/1987] Labeling and MSDSs for a stump router cutter head which has carbide tips on the cutter teeth.[1910.1200(f); 1910.1200(g)]
- [10/09/1987] Clarification of Material Safety Data Sheet Requirements Under the Hazard Communication Standard.[1910.1200]
- [10/07/1987] Safeguarding of Metal Cutting Do-All Saw at the Norfolk Naval Shipyard.[1910.212]
- [10/05/1987] Additional requirements for distributors from the August 24, 1987 expansion of the HCS.[1910.1200]
- [10/01/1987] Retention requirements for superseded MSDSs.[1910.1200(g)]
- [10/01/1987] Appeal's court rules that modular housing assembly will be regulated as manufacturing.[1926]
- [09/26/1987] Lift Slab Construction.[1926.700]
- [09/24/1987] Temporary lighting branch circuits.[1926.405; 1926.449]
- [09/24/1987] Clarification of revised Subpart K, Electrical Standard for Construction, 1926.403(a).[1926.403(a)]
- [09/23/1987] Definition, application and use of "Horns".[1926.602]
- [09/17/1987] Definitions of target organ and hazards of chemicals under the Hazard Communication Standard.[1910.1200]
- [09/17/1987] Application of the Hazard Communication Standard to art materials industry.[1910.1200]
- [09/15/1987] Respiratory protection compliance responsibility for contract workers and visitors.[1910.134]
- [09/10/1987] National Paint and Coatings Association's (NPCA) Health Effects Labeling Approach[1910.1200]
- [09/08/1987] Clarification of the requirement for representative monitoring under the asbestos standard for construction.[1926.1101(f)]
- [09/01/1987] Requirements of 1910.177, Restraining Devices and Barriers.[1910.177]
- [08/25/1987] Presence of chromium in monocomponent photocopier toner is under investigation.[1910.1200]
- [08/20/1987] Horns and audible alarms.[1926.602(a)(9)(i)]
- [08/20/1987] Definition of "statistically reliable measurements" in 1926.58(f) (4).[1926.58(f)(4)]
- [08/18/1987] Applicability of the HCS to manufacturers of steel coils.[1910.1200]
- [08/14/1987] Manually controlled top loading operations of tank vehicles.[1910.106(f)(3)(iii)]
- [08/13/1987] Fall protection for employees exposed to hazardous falls from roofs.[1910.66(e)(3); 1910.23; 1910.145(c)(3)]
- [08/11/1987] Access ladder for scaffolds.[1926.450]
- [08/07/1987] Safe working load of ship's gear in union purchase[1918.51(a); 1918.51(b)]
- [08/07/1987] Cancer warning labels for formaldehyde and products containing formaldehyde.[1910.1200(f)]
- [08/06/1987] OSHA policy regarding medical surveillance requirements.[1910.1025]
- [07/27/1987] Free audiometric testing for employees exposed over the action level.[1910.95]
- [07/18/1987] Grounding of a person in a wheelchair to eliminate static electricity.
- [07/16/1987] Anchors required for two-point suspension scaffolds.[1910.28(g)(11); 1910.66(e)(2)]
- [07/13/1987] Guarding requirements for the "Speed Cut" radial saw.[1910.213(h)(1)]
- [07/10/1987] Advertisement on cleaning up mercury spills from glass thermometers.[1910.1000]
- [07/09/1987] The use of "steel duck billed hammers".[1910.177]
- [06/30/1987] Medical surveillance requirements in the vinyl chloride standard.[1910.1017]
- [06/29/1987] Training requirements in the hazardous waste interim final rule, 1910.120(e)(2) and (3).[1910.120(e)(2); 1910.120(e)(3)]
- [06/29/1987] The HCS's requirement for target organ effects on labels for shipped containers of hazardous chemicals.[1910.1200]
- [06/24/1987] IARC listing of boot and shoe manufacturing and repair as an occupation associated with cancer in humans.[1910.1200]
- [06/16/1987] Housing Construction Operations.[1926.501(b)(13)]
- [06/15/1987] Recertifying technicians who do audiometric testing and pulmonary function testing.[1910.95; 1926.58]
- [06/11/1987] HMIS for meeting labeling requirements of the HCS.[1910.1200(f)]
- [06/09/1987] Requirement for instituting engineering and administrative controls for noise.[1910.95]
- [06/05/1987] Letter to DASHOS regarding reprisals.[1960]
- [06/03/1987] Laser standards applicable to a surgical laser program.
- [05/21/1987] HMIS use in meeting the in-plant labeling requirements of the HCS.[1910.1200(f)]
- [05/04/1987] OSHA currently has no enforceable standard for paper dust.[1910.1000 TABLE Z-3]
- [05/04/1987] Evaluation of labeling system which was designed to meet the requirements of the HCS.[1910.1200(f)]
- [04/14/1987] Use of Walkman Radio, Tape, or CD Players and Their Effect When Hearing Protection Is In Use[1910.95(i)(2)(i); 1910.95(i)(2)(ii)]
- [04/07/1987] Use of eyeglass inserts or spectacle kits inside respirator full facepieces.[1910.134]
- [04/07/1987] Employees engaged in erection, may ride a material hoist to gain access or egress to their work during the erection.[1926.552]
- [03/27/1987] Information regarding exposure to lead and sulfuric acid.[1910.1025]
- [03/24/1987] Acceptance of closed-circuit self-contained breathing apparatus for firefighting.[1910.134]
- [03/20/1987] Protection provided by powered air-purifying respirators.[1910.134(g)(1)(i); 1910.134(g)(1)(ii); 1910.134(g)(1)(iii)]
- [03/18/1987] Calculating of hearing threshold shifts.[1910.95]
- [03/16/1987] Applicability of 1910.180(b)(1) to cranes used with drag line, pile driver or clam shell attachments.[1910.180(b)(1)]
- [02/26/1987] PCBs in fluorescent light fixtures.[1910.1000 TABLE Z-1]
- [02/20/1987] Electrical Standards for Construction, Revised Subpart K[1926 Subpart K]
- [02/18/1987] Use of amyl nitrite pearls as an antidote for acrylonitrile poisoning.[1910.1045]
- [02/17/1987] OSHA has no standards for the design and implementation of video display workstations.
- [02/11/1987] Information on Hydro Carbide Tungsten, otherwise known as cemented tungsten carbide with colbalt binder.[1910.120]
- [02/01/1987] Interpretation on requirements for opening drums in a safe manner.[1910.120(j)]
- [01/21/1987] "Obstructed view to the rear" relative to use of back-up alarms.[1926.602(a)(9)(ii)]
- [01/20/1987] Clarification of the terms "appropriate hazard warning" and "mandatory".[1910.1200(f); 1910.1200(d)(2)]
- [01/13/1987] Plans are required for EtO emergency situations and must be written in accordance with 1910.38 and 1910.39.[1910.1047; 1910.1047(h)(1); 1910.1047(h)(1)(iii); 1910.38; 1910.165]
- [01/09/1987] Line maintenance on a de-energized transmission line.[1926.551; 1926.950(c)]
- [01/08/1987] Means of alerting employees during EtO emergency situations in hospitals;direct voice communication may be used to warn employees during an EtO emergency.[1910.1047; 1910.1047(h)(2); 1910.165; 1910.38; 1910.39]
- [01/08/1987] Clarification of the jurisdiction's of OSHA and the NRC in nuclear power plants.[1910.1096]