The provisions of this section shall apply to ship repairing, shipbuilding, and shipbreaking except that paragraph (c) of this section
applies to ship repairing and shipbuilding only.
1915.93(a) Steam supply and hoses.
1915.93(a)(1) Prior to supplying a vessel with steam from a source outside the vessel, the employer shall
ascertain from responsible vessel's representatives, having knowledge of the condition of the plant, the safe working pressure of the vessel's steam
system. The employer shall install a pressure gauge and a relief valve of proper size and capacity at the point where the temporary steam hose joins
the vessel's steam piping system or systems. The relief valve shall be set and capable of relieving at a pressure not exceeding the safe working
pressure of the vessel's system in its present condition, and there shall be no means of isolating the relief valve from the system which it protects.
The pressure gauge and relief valve shall be located so as to be visible and readily accessible.
1915.93(a)(2) Steam hose and fittings shall have a safety factor of not less than five (5).
1915.93(a)(3) When steam hose is hung in a bight or bights, the weight shall be relieved by appropriate lines. The
hose shall be protected against chafing.
..1915.93(a)(4)
1915.93(a)(4) Steam hose shall be protected from damage and hose and temporary piping shall be so shielded where
passing through normal work areas as to prevent accidental contact by employees.
1915.93(b) Electric power.
1915.93(b)(1) When the vessel is supplied with electric power from a source outside the vessel, the following
precautions shall be taken prior to energizing the vessel's circuits:
1915.93(b)(1)(i) If in dry dock, the vessel shall be adequately grounded.
1915.93(b)(1)(ii) The employer shall ascertain from responsible vessel's representatives, having knowledge of the
condition of the vessel's electrical system, that all circuits to be energized are in a safe condition.
1915.93(b)(1)(iii) All circuits to be energized shall be equipped with overcurrent protection of capacity not
exceeding the rated current carrying capacity of the cord used.
1915.93(c) Infrared electrical heat lamps.
1915.93(c)(1) All infrared electrical heat lamps shall be equipped with guards that surround the lamps with the
exception of the face, to minimize accidental contact with the lamps.
|