Fatality Assessment and Control Evaluation (FACE) Program |
![]() |
Pipefitter/Project Foreman Died When Struck by Ruptured Sewer Pipe/Mechanical Plug |
![]() |
|
||||||||||||||||||||||||||||||||||
The free Adobe Acrobat Reader is needed to open some of the files on this page.
You can download Acrobat Reader from adobe.com
SummaryOn March 30, 2007, a 53-year-old male pipefitter and project foreman for a mechanical contractor died when a storm sewer pipe and inflatable plug dislodged and struck him causing fatal injuries to his chest and abdomen. The three-person crew was in a county park’s lift station to replace two pumps. The water was pumped down and the decedent and Coworker #1 went down to the bottom of the manhole to install a mechanical plug into a 26-inch diameter storm sewer pipe that drained into the lift station. The plug was inflated and the water stopped flowing into the station. Coworker #2 was at the top of the 10- x 10-foot manhole monitoring the situation. The decedent and Coworker #1 installed a pump base anchor in the floor directly in front of the mechanical plug they had installed in the sewer line. No blocking or bracing was installed in front of the plug. While the decedent and Coworker #1 were drilling anchor holes in the floor, the wall, sewer pipe and plug exploded into the manhole, striking both employees (Figure 1). The decedent was knocked unconscious and Coworker #1 was thrown across the lift station. Coworkers #1 and #2 lifted the decedent to the 2nd level of the lift station and started CPR. When emergency response arrived, they extricated the decedent from the 2nd level and transported him to a local hospital where he later died.
Recommendations:
IntroductionOn March 30, 2007, a 53-year-old male pipefitter/project foreman for a mechanical contractor died when storm sewer pipe and inflatable pneumatic plug ruptured and struck him in his chest and abdomen. On the same day as the fatal incident, MIFACE investigators were informed by the Michigan Occupational Safety and Health Administration (MIOSHA) personnel, who had received a report on their 24-hour-a-day hotline that this work-related fatal injury had occurred. On July 10, 2007, MIFACE interviewed the company owner at the company headquarters and was given a tour of the facility. During the course of writing this report, the police report and pictures, fire response report, medical examiner report, and the MIOSHA file and citations were reviewed. The pictures used in Figures 1 and 3 are courtesy of the company owner. Figures 2, 4, 5, and 6 are courtesy of the MIOSHA file. The employer, a mechanical installation contractor for commercial, industrial, and institutional facilities had been in business for over 25 years. The firm employed 85 individuals, 12 of whom had the same job title as the decedent, project foreman. The decedent had been employed with this firm for 20 years and worked full time. Employees worked 9 hours per day, starting work at 6:00 a.m. and concluding at 4:00 p.m. The employer had a written health and safety program, but no specific procedures for the task being performed. The company did not have a Health and Safety Committee. The firm participated in the National Associated Builders and Contractors Inc. 2007 Safety Training and Evaluation Process (STEP) program and had been awarded a “Gold Level Achievement Award.” The company had a written progressive disciplinary procedure: 1st violation resulted in a verbal warning, the 2nd violation resulted in a written warning, and the 3rd violation resulted in possible termination. The company’s safety director was a health and safety consultant employed by a consulting firm. The safety director had many responsibilities, including conducting regular safety inspections of shop and field operations, as well as holding safety meetings with all employees and conducting safety training of supervisory personnel. The safety director visited company job sites two times per month and provided the company owner a written report on noted violations. Crew foremen were responsible for safety at the job site (instruct crew in proper and safe operation of tools, equipment and procedures for every job) and to correct all noted violations at the time of the consultant’s site visit. The foreman was responsible for conducting adequate safety briefings and inspection of tools as well as equipment before any job was started. The crew foreman observed work in progress to ensure that safety precautions were taken at all times, and was required to take immediate steps to correct any unsafe procedure or hazardous condition. The employer, safety consultant, and crew foreman presented health and safety training and topics to company employees. Employees received health and safety training on an annual basis by the safety consultant. The crew foreman was responsible for presenting specific health and safety topics during monthly safety meetings and weekly toolbox talks, and for maintaining training documentation. Supervisors and foreman were responsible for determining if an employee needed retraining. The company had a written confined space entry program. The decedent had been trained and authorized to use the confined space gas monitor in 1997. A confined space entry permit had been developed to monitor for oxygen, carbon monoxide, and LEL. At the conclusion of their investigation, MIOSHA Construction Safety and Health Division issued the following Serious citations to the employer:
Back to TopInvestigationThe company for whom the decedent (Company A) worked had been contracted by a county parks department to replace two old and failing pumps and a ladder at a park lift station. Company B was subcontracted to install the ladder. The park’s storm water drains into the lift station and the lift station then lifts the water to a local river. The manhole had corrugated metal walls. The base of the lift station was 30 feet deep. There was a 2nd level, accessible by ladder approximately 15 feet down. The 2nd level had a 2-foot walk around. A ladder provided access to the base of the manhole where the work was to be performed. On the day before the incident, Company A’s field superintendent conducted an informal inspection of the lift station and found nothing out of the ordinary. The superintendent did find that the sewer pipe, which was installed in the 1920s, was larger than expected. Company A usually used Cherne® Best Ball 18”-1 ½” mechanical plugs, installing them per manufacturer’s instructions. Because Company A did not have the properly sized plug for the pipe, the field superintendent borrowed a Lansas® 24-48-inch pneumatic pipe plug from a local contractor. According to the MIOSHA file, no safety instructions were given to the Company A employee who picked up the Lansas® plug. The company from whom the plug was rented did not have records of gauge calibration. According to the MIOSHA file, if the gauges appeared to be faulty, they were discarded and replaced. The superintendent did not obtain any manufacturer’s installation instructions from the local contractor. The decedent and Coworker #1 transported this larger plug to the lift station. The decedent and Coworker #1 arrived at the company shop location at 5:45 a.m. They loaded a truck with a generator, air compressor, air line, safety harnesses, hoist block (chain fall), test equipment for air monitoring, and other miscellaneous tools. They arrived at the worksite at approximately 7:30 a.m. The weather was sunny and chilly. The decedent and Coworker #1 began to unload the truck. They set up a 2-inch sump pump. After evaluating the air in the confined space, the decedent descended into the manhole as Coworker #1 lowered the sump pump into manhole. The decedent placed it in the rear corner of work area. They turned on the pump and water began to discharge through a hose onto the above ground street. The decedent left the work site and traveled to another nearby project to pick up rubber thigh-high boots. Coworker #1 began to set up the chain fall, hooked up the test plug and began to lower it into the manhole, and set up the air compressor, generator, and tools. He also opened up the electrical cabinet. At approximately 8:00 a.m., Coworker #2 arrived at the jobsite (Figure 2). Coworker #1 and Coworker #2 began to discuss the work plan. A representative from the county’s park department arrived and asked “What are you doing today?” and “What is the game plan?” Coworkers #1 and #2 responded and then prepared for the confined space documentation and equipment. They went through the checklist, turned on the atmospheric testing equipment (sniffer) and lowered it down into the manhole. Coworker #2 checked the readings from the sniffer and verbalized the readings.
The decedent arrived with the boots as Coworkers #1 and #2 were finishing the confined space readings. The decedent and Coworker #2 put on the rubber boots. At approximately 9:00 a.m., the decedent and Coworker #2 entered the manhole while Coworker #1 stayed above ground at the open manhole to observe and listen. Coworker #1 released the hoist while lowering the plug. With constant verbalization and teamwork between the three men, it took approximately 15 to 17 minutes to lower the test plug into the manhole and to place it into the sewer pipe. Coworker #2 used the shovel to clean the 26-inch cast iron sewer pipe. The decedent guided the plug into the sewer pipe while Coworker #2 used the wooden handle of the shovel to help insert the plug. After the pipe plug was positioned, they told Coworker #1 to turn on the air compressor to inflate the plug. Coworker #1 did so and monitored the air gauge. Employee statements provided to the MIFACE researcher stated that the plug was pumped per manufacturer’s recommendations to eight pounds. Statements made to the MIOSHA compliance officer differed from the employee statements given to the MIFACE researcher. The employee statements given to the MIOSHA compliance officer at the time of the investigation indicated that the employees did not know the required plug inflation pressure or the plug’s inflation pressure at the time of the incident. The decedent and Coworker #2 stayed in the bottom of the lift station and yelled up to Coworker #1 when the water stopped flowing from the sewer pipe. Coworker #1 communicated to the decedent and Coworker #2 that all systems were good. Coworker #1 then collected the necessary tools in a bucket, and while watching the air gauge, he lowered the bucket to the crew below. Coworker #1 was at the top of the manhole monitoring the situation and the pump. The decedent and Coworker #2 then proceeded to install a pump base anchor in the floor directly in front of the mechanical plug they installed in the sewer line. No blocking or bracing was installed in front of the plug as required by the manufacturer to protect the workers in case of a plug failure Coworker #2 used the shovel to clear six to eight inches of sand away from the working area to determine what kind of anchors were required. The 2-inch sump pump continued to keep the water level under control. They decided what anchors were needed and then headed back up out of the manhole. Employees from Company B arrived at the pump house. Company B’s employees entered the well house and descended to the second level to discuss the installation procedure for the new ladder. A Company B employee reviewed the ladder installation procedure with the decedent and then left the jobsite. The decedent left the jobsite to obtain materials needed for the anchor and ladder installation. Coworker #2 went back down into the manhole after discussing the game plan with the Company B. Coworker #2 chopped out the old ladder and it was pulled out and then the new one was dropped into the manhole. Coworker #2 exited the manhole and Company B employees entered and after determining that the ladder was properly set, left the manhole. When the decedent arrived back at the jobsite, the decedent and Coworker #2 descended to the lower level of the manhole to install the anchors. They took a small drill with them. They discovered the drill had the wrong size bit. After discussing various options, the decedent and Coworker #2 still could not drill with the small drill. They yelled up to Coworker #1 to get the big drill, which was already loaded and ready to go. Coworker #1 lowered the drill down while continuing to monitor the air.
Within the next 60 seconds, they noticed the sump pump was not keeping up and water was coming in and had risen to their ankles. Water was leaking from the wall, not out of the pipe. The decedent knelt down to drill the second hole with the drill. Coworker #2 saw brownish water in the bottom corner near the plug. Coworker #2 told the decedent to move out of the way, he would take care of the anchor. He was on his knees 15 inches away from the decedent. When Coworker #2 knelt down, he felt air by his face as the force of the explosion picked him up and blew him to the other side of the manhole (Figure 3). Coworker #2 was uncertain if he was knocked unconscious or if so, the length of time he was unconscious. He got up from a fetal position and water in the manhole was chest high. As he came to, he went to the decedent who was visibly injured. Coworker #2 looked up toward the top of the manhole, but it was “raining” air – the air was filled with white powder and dust particles. Coworker #1 could not see the two individuals in the manhole. Coworker #2 yelled to Coworker #1,“we’re in trouble.” He instructed Coworker #1 to call 911, and then to call the company office. Coworker #2 had difficulty in pulling the decendent above the water because of the height of the water/mud/sand. Coworker #2 told Coworker #1 to turn the big pumps on; Coworker #1 complied. Coworker #2 asked Coworker #1 for a pipe strap so he could hoist the decedent. He lassoed the decedent under the arms to pull him up. Coworker #1 began hoisting the decedent out of the water while Coworker #2 yelled instructions from below. Coworker #2 ascended to the 2nd level and laid the decedent on two 2x10 boards. He asked Coworker #1 to come down to the 2nd level because he realized the decedent was not breathing. Coworker #2 held the decedent against his leg as Coworker #1 administered CPR. The decedent began to breathe. The police arrived first. Then an EMT arrived and inquired if it was sewage in the hole. Coworker #2 responded that it was groundwater. When individuals from a local fire department technical rescue team arrived, they assumed command. After assessing the situation, they entered the manhole, assisted the EMT and asked Coworkers #1 and #2 to leave. The rescue workers moved the decedent from the boards to a stokes basket and the decedent was lifted from the manhole. EMT personnel transported the decedent by ambulance to a local hospital where he died several hours later.
The pipe plug was found laying on the floor of the manhole and recovered. When the water was pumped out, the plug in the pipe could be seen (Figure 4). Part of the concrete pipe was still attached to the plug. The plug was over eight feet long and had metal plugs on both ends (Figure 5). Pictures indicate that the concrete gave way causing the plug to shoot out due to water pressure (Figure 3). The plug had an approximately 16-inch cut that appeared to happen when the pipe broke. The cut looked as though it was done by a sharp object and not from blowing under pressure (Figure 6). The entire plug would have been inside of this pipe prior to it blowing out.
The MIOSHA file documentation indicated that both surviving Company A employees had never used or installed this type of large inflatable plug before, had not read the manufacturer’s instructions (including installation instructions), and had not received any formal training about this plug from their employer. They stated they had used the smaller pipe plugs that their company owned many times before and that they did not install this pipe plug any differently from their work practice in the past. Company A had the manufacturer’s installation instruction for the pipe plugs usually used at the company’s office. The employees also indicated that they did not know if the pressure gauge on the rented pipe plug had been calibrated. The work crew had not made any back test pressure calculations or head pressure/back pressure calculations. Back to TopCause of DeathThe cause of death as stated on the death certificate was multiple blunt injuries of chest and abdomen. Toxicology was negative for alcohol and illicit drugs. Back to TopRecommendations/DiscussionEmployers should ensure that workers follow all pneumatic pipe plug manufacturer's safety recommendations and other safety precautions relevant to the safe installation and use of pneumatic pipe plugs.The employer usually used Cherne® pipe plugs, but for this worksite, they used a Lansas® pipe plug. The employer had the Cherne® safety literature at the company headquarters, but had not obtained any Lansas® pipe plug literature. MIFACE conducted an Internet search and found safety information for both the Lansas® and Cherne® pipe plugs. The Lansas® Products website (http://www.lansas.com/index.htm) had both written safety instructions and viewable safety videos (in both English and Spanish). The Cherne® Safety Manual may be found at: http://www.cherneind.com/aboutus.asp. Click on Literature, and scroll down to Safety Information. The company and the safety director should obtain and review the safety literature for any pipe plugs they use and ensure that the safety protocols are understood and followed. Safety precautions identified in the installation instructions for the Cherne® plugs and the Lansas® pipe plug used in the incident were strikingly similar. Table I highlights some of these precautions.
The crew stated to the MIOSHA compliance officer that they installed the Lansas® plug in the same manner as they would have installed the Cherne® plug (the plug they usually used). The “normal” manner was in violation of the Cherne® Safety Instruction manual. For example:
The employees indicated that no water was flowing from the pipe after the plug was inflated. This may have placed undue pressure on the pipe, potentially contributing to its failure. Although it is unknown if the plug was over inflated, over inflation will not provide a better seal and the plug may rupture catastrophically and dislodge at high velocity. Employers should develop written confined space programs that contain specific procedures for all tasks to be performed and ensure employees follow the procedures.A confined space means any space having a limited means of egress that is subject to the accumulation of toxic or flammable contaminants or has an oxygen deficient atmosphere. Confined or enclosed spaces include, but are not limited to, storage tanks, process vessels, bins, boilers, ventilation or exhaust ducts, sewers, underground utility vaults, tunnels, pipelines, and open top spaces more than four feet in depth such as pits, tubs, vaults, and vessels. Some of the company’s confined space protocols were followed, for example, evaluating the air prior to entry and having an employee available in the immediate vicinity to assist in rendering assistance. A hazard assessment of a job that requires working in a lift station manhole should identify possible engulfment if the plug or wall should fail. With this hazard identification, the confined space procedure should identify that safety harnesses be worn by each of the employees in the manhole. Although the wearing of the safety harnesses would not have prevented the fatality, the rescue of the injured worker would have proceeded more quickly and at less risk to the injured.
|
||||||||||||||||||||||||||||||||||||
![]() |
||||||||||||||||||||||||||||||||||||
![]() |