![]() |
|
![]() |
Fatality Assessment and Control Evaluation (FACE) Program |
![]() |
Construction Foreman Dies from Fall While Climbing the Tower of a Hydromobile Scaffold |
![]() |
|
||||||||||
The free Adobe Acrobat Reader is needed to open some of the files on this page.
You can download Acrobat Reader from adobe.com
SummaryOn February 6, 2007, a 56-year-old male construction foreman of a masonry crew was critically injured when he fell while climbing the tower of a hydromobile scaffold system, Model #MU724J. While climbing the scaffold, he may have had a cerebral infarction (blockage of the flow of blood to the cerebrum, causing or resulting in brain tissue death). He died two days later. The scaffold’s 60-foot long, 5-foot wide platform access was located 32 feet from the ground. The fixed ladder supplied by the manufacturer was not installed. Two members of the crew, Coworker #1 and Coworker #2, climbed the scaffold tower to the platform to prepare the wall and winterize the scaffold. The decedent arrived and began to climb the tower to access the platform. When the decedent was approximately six to ten feet above the ground, Coworker #1 witnessed the decedent suddenly fall backwards from the scaffold to the ground and then roll to his left side. Coworker #1 descended from the scaffold to assist the decedent. The decedent was unconscious but still breathing. Coworker #2 descended to stay with the decedent while Coworker #1 ran to the general contractor’s work trailer for assistance. Emergency response was called. Emergency response arrived, and after approximately one hour, the decedent was airlifted to a local hospital where he died two days later.
Recommendations:
IntroductionOn February 6, 2007, a 56-year-old male construction foreman of a masonry crew was critically injured when he fell while climbing the tower of a hydromobile scaffold. He may have experienced a cerebral infarction while climbing. He died two days later from complications due to the injuries he sustained at the time of the incident. The Michigan Occupational Safety and Health Administration (MIOSHA) personnel received the fatality report on their 24-hour-a-day hotline on February 8, 2007. MIOSHA notified MIFACE personnel later that day. The MIFACE researcher interviewed the company’s Vice President/Safety Director on July 17, 2007 at the company’s headquarters. The Vice President/Safety Director escorted the MIFACE researcher to the storage yard where several hydromobile scaffolds were located. During the course of writing this report, the death certificate, medical examiner report, the police report, and the MIOSHA file and citations were reviewed. Pictures used in Figures 1, 2, and 3 are courtesy of the MIOSHA file. The MIFACE researcher took the picture used in Figure 4 at the time of the site visit. The employer for whom the decedent worked was a commercial, institutional and industrial masonry contractor. The firm had been in business over 40 years. The peak summer employment was 80 to 90 individuals. The decedent was a member of the union. He worked full time, 8.5 hours a day. The decedent was one of 12 foremen and had 20 years of experience as a foreman. The decedent had been employed by the company for 20 years. The employer created a site-specific written accident prevention program for this project in addition to the company-specific health and safety program. The Safety Director had on the job safety experience and reported directly to the company owner. The Safety Director indicated he had visited the site two to three times per week prior to the incident. He also visited the site on the day of the incident. The decedent’s employer utilized outside consultation to provide assistance in the development of sections of the program. The scaffold manufacturer helped to develop and instruct employees on the scaffold safety section of the program. Additionally, the hydromobile scaffold representative provided train-the-trainer instruction to selected company employees. The company was also a member of a local mason contractors association. The association provided an avenue to discuss common job site concerns, provided health and safety training, etc. The decedent had received hydromobile scaffold training in 1998 and had taken a refresher course within the past two years. The hydromobile scaffold manufacturing representative provided the training. The decedent had a masonry certificate from the masonry institute and had attended the MIOSHA 30-hour training. The decedent’s coworkers at the site had received hydromobile scaffold training on this particular model in addition to training at the Laborer’s Training Institute. The company sent its employees to other safety training classes provided by MIOSHA CET, trade groups, and equipment manufacturers. The company provided two foreman meetings per year to discuss health and safety issues. The company emphasized health and safety issues identified as needing the most improvement. The Safety Director led a pre-job meeting at the site prior to beginning the work. The pre-job meeting included talking about the structure itself, discussing the scaffold to be used, wall bracing, and any other issues that might be considered unusual. The company utilized scaffold manufacturer representatives to assist in the layout of a scaffold system on a difficult project. As foreman, the decedent was responsible for implementing and enforcing the company’s safety policy at the jobsite. The decedent led weekly toolbox talks developed by the Safety Director. The Safety Director ensured that the toolbox talk subject matter was pertinent to the job or surrounding conditions. The employer had a written progressive disciplinary policy that had three steps. The first step was a verbal warning. The second step was a written warning, and the third step was time off. The firm did not have a health and safety committee. MIOSHA Construction Safety and Health Division issued the following alleged Serious citation and Other-than-Serious citation at the conclusion of its investigation:
Back to TopInvestigationThe company was a site subcontractor for a building addition on a financial building. The employer was engaged in exterior masonry type work and had been at the site for approximately three weeks. The motorized hydromobile scaffold, Model #MU724J had been erected a week prior to the incident day. The scaffold was 60 feet long and 5 feet wide. The work platform access was located 32 feet above the ground. The manufacturer had a ladder system available but it had not been purchased by the company at the time of the incident. The scaffold had been winter protected by wrapping it in plastic. The plastic wrap also acted as a wind shield so the masonry could cure. The Safety Director indicated to the MIFACE researcher that the company inspected the scaffold on a daily basis and throughout the day. The decedent was the foreman of a three-person crew. The decedent’s coworkers, Coworker #1 and Coworker #2, arrived at the work site at 7:30 a.m. The Safety Director had visited the site and had left to observe another job. The decedent arrived at 9:00 a.m. The decedent’s coworkers were preparing the wall for upcoming work and setting up plastic weather protection around the scaffold. The coworkers took their morning break and returned to the scaffold. The workers had been on the scaffold for a few minutes when the decedent arrived and attempted to communicate something to them, but they could not hear him. The decedent began to climb the tower to access the platform. After climbing six to ten feet, he suddenly fell backwards to the ground below. It was later learned that the decedent may have had a cerebral infarction as he was climbing the tower. When he fell, his head hit the ground, and may have also struck rocks and anchor bolts (Figure 2). He was wearing a hard hat and safety glasses. After landing on the ground six to eight feet from the scaffold and within six inches of the concrete foundation, he rolled over to his left side. His safety glasses were under this head. After a few seconds, Coworker #1 descended from the scaffold to assist the decedent. The decedent was unconscious but still breathing. Coworker #2 then descended from the scaffold and stayed with the decedent while Coworker #1 ran to the general contractor’s trailer to request assistance. After learning of the fall, an individual in the trailer (Worker A) ran outside and told a bystander to go inside the lobby of the building under construction and call 911. Worker A went to the decedent’s location to make sure he was breathing. This individual and other workers at the site placed their jackets over the decedent to keep him warm until emergency assistance arrived. While awaiting emergency response, Worker A instructed the laborers present to direct medical personnel to the decedent’s location and to help with activities to clear the area for emergency response (i.e., remove a section of fence) and a life flight helicopter to land.
Worker A called the decedent’s employer to inform him of the incident. The Safety Director, who had left 40 minutes earlier, returned to the site. After emergency response arrived, the decedent was treated and moved to the ambulance to be driven to the area where a life flight helicopter could land and transport him to the hospital. Neither the hydromobile ladder nor an extension ladder was available at the worksite at the time of the incident. The crew had been accessing the platform by climbing the towers. After the incident, an extension ladder (Figure 3) was brought to the site and appropriately affixed to the scaffold.
Back to TopAbatementAfter the incident, the company initiated several preventative measures to address several factors in this incident:
Back to TopCause of DeathThe death certificate listed the cause of death as multiple injuries and cerebral infarction due to or as a consequence of a left carotid artery thrombosis. Toxicological tests were negative for alcohol and illicit drugs. Back to TopRecommendations/DiscussionEmployers should ensure that scaffold safety components are provided and appropriately attached to the scaffold to provide safe access to the scaffold platform prior to use.Although some hydromobile scaffolds are designed to permit climbing of the towers, the scaffold involved in this incident was not designed to permit tower climbing because of the diagonal braces in the towers. The scaffold manufacturer had designed a ladder/guard rail system to overcome this situation. Ladder sections, like the towers, came in 60-inch sections, which could be attached/detached by the scaffold erector as the scaffold was raised/lowered. Alternatively, an employer could provide platform access by meeting the following requirements of Rule 1211(1) of the MIOSHA Construction Safety Standard Part 12, Scaffolds and Scaffold Platforms:
Employers should develop a checklist to ensure all unattached scaffold components are included in the shipment to the site.The company transported the scaffold system from the staging yard to the construction site by tractor-trailer in addition to tools and other items needed at the site. A checklist provides employees an “at a glance” list of the necessary equipment to be loaded on the trailer for a particular construction site. The checklist can also serve as a reminder of equipment that is needed at the job site and was not delivered.
|
||||||||||||
![]() |
||||||||||||
![]() |