Click the image to enlarge

In this U.S. Bureau of Mines study, four underground respirable dust surveys were conducted to determine factors affecting belt entry dust levels and how using belt air to ventilate work areas affected dust exposures. Belt entry dust levels on the surveyed longwall and continuous miner sections averaged 0.59 and 0.26 Mg/m3, respectively. The stageloader-crusher contributed an additional 0.5 to 0.9 Mg/m3 of dust to belt air, while the feeder-breaker contributed 0 to 0.2 Mg/m3 of dust. A 1,000-ft increase in belt entry length or a 200- to 500-st-per-shift increase in production resulted in roughly a 0.1-Mg/m3 increase in dust. Using the belt entry as an intake entry on the continuous miner section appeared to reduce dust levels by 0.1 to 0.3 Mg/m3 during cutting. Belt air was not used to ventilate the face on the longwall section.

Author(s):Potts-JD, Jankowski-RA
Reference:U.S. Department of the Interior, Bureau of Mines, Report of Investigations 9426, 1992:1-12