Additional Guidance for CHECK-RAS, Version 1.4

There are some known problems with CHECK-RAS, Version 1.4. These problems are not significant enough to warrant a new release of the application, however, they may result in some user difficulty with the software. This page describes the known problems and presents possible solutions to help users avoid and/or deal with problems should they arise.

If you are having a problem with CHECK-RAS, Version 1.4, that is not addressed on this page, please fill out our software comment form so that the issue can be reviewed and handled in an appropriate manner.

question Problem 1: CHECK-RAS will not run if a stream does not have a reach name.

solution Solution: Assign a reach name when drawing the schematic diagram.

question Problem 2: The FW SW 04 message is printed when the total conveyance of the floodway profile and the natural profile are the same.

solution Solution: If the total conveyances are the same, ignore the message.

question Problem 3: When extracting data from a HEC-RAS file, the error "checkras id <> csid" followed by "Error: data extract" appears and the program stops extracting the data.

solution Solution: This problem occurs as a result of one of the following reasons:

  1. The Summary of Errors, Warnings and Notes box was checked in the Report Generator window in HEC-RAS. This box should be unchecked, or
  2. When installing CHECK-RAS from the web site, the user must follow the instructions completely. The following lists the steps to be followed by the user.

The Steps outlined in bold are the most frequent problems. The user usually forgot to do the bolded steps.

After the CHECK-RAS program installs the CHECK-RAS user table into HEC-RAS, the user can generate report file in HEC-RAS. However, after closing the Report Generator window, the user must click on the File menu and click "Save Project" before closing the HEC-RAS main window.

question Problem 4: Is CHECK-RAS compatible with Windows XP?

solution Solution: CHECK-RAS version 1.4 is compatible with Windows 98, NT, 2000 and XP.

question Problem 5: Regardless of whether the CHECK-RAS User's Manual is downloaded, or Acrobat Reader is used directly from the website, the graphics are not available. When trying to download or open Acrobat Reader, the error message "Could not find colorspace named 'Cs8"appears.

solution Solution: The user needs to use the latest version of Adobe Reader to view the file. Using an earlier version of Acrobat Reader will often result in file display problems. To find out which version of the Reader that you have, open Acrobat Reader by clicking on the program icon on your desktop. If you don't have a desktop icon for the application, you can also launch the program from the Start menu. The program should be located at "Start > Programs > Acrobat Reader." After the program opens, select "About Acrobat Reader" from the "Help" menu to view the application version information. If you don't have the latest version of Adobe Reader on your system, download the free Adobe Reader upgrade.

The following are known problems and will be resolved in the next release.

question Problem 6: CONSPAN entrance loss coefficients need to be included.

question Problem 7: HEC-RAS 3.1.2 does not allow the user to insert encroachment method at the structures from the Steady Flow Analysis/Options/Encroachments window. The floodway message must be corrected.

question Problem 8: Although CHECK-RAS can extract data from SI unit files of HEC-RAS version 3.1.2, it shows zero discharge values under Q Total column in XS Check report. It also shows "Type of Flow Unknown" message at structures in Structure Check report. CHECK-RAS should not be used for the SI unit files of HEC-RAS version 3.1.2.