pmc logo imageJournal ListSearchpmc logo image
Logo of opendentjJournal URL: redirect3.cgi?&&auth=0voPNyYIgKyfxqYWfaBjM7GmVJqfQNy5EzTfy_Q7C&reftype=publisher&article-id=2581534&issue-id=173529&journal-id=688&FROM=Article|Banner&TO=Publisher|Other|N%2FA&rendering-type=normal&&http://www.bentham.org/open/todentj/index.htm
Open Dent J. 2008; 2: 13–17.
Published online 2008 January 22. doi: 10.2174/1874210600802010013.
PMCID: PMC2581534
Effect of the Simulated Disinfection by Microwave Energy on the Impact Strength of the Tooth/Acrylic Resin Adhesion
Rafael L.X. Consani,1* Marcelo F. Mesquita,2 Marinaldo H. Zampieri,3 Wilson B. Mendes,4 and Simonides Consani5
1Department of Prosthodontics and Periodontics, Piracicaba Dentistry School, State University of Campinas, Brazil;
2Department of Prosthodontics and Periodontics, Piracicaba Dentistry School, State University of Campinas, Brazil;
3Piracicaba Dentistry School, State University of Campinas, Brazil
4Department of Clinics, Itauna University Dentistry School, MG, Brazil
5Department of Restorative Dentistry, Piracicaba Dentistry School, State University of Campinas, Brazil.
*Faculdade de Odontologia de Piracicaba, UNICAMP, Av. Limeira, 901, 13414-903 - Piracicaba, SP, Brazil; Tel: (55) 19- 21065296; E-mail: rconsani/at/fop.unicamp.br
Received October 25, 2007; Accepted December 12, 2007.
Abstract
The objective of this study was to determine the effect of simulated microwave disinfection on the tooth/acrylic resin impact strength. Acrylic molar teeth with a wax stick attached to the ridge lap were included in brass flasks. Specimens were made with Classico thermopolymerized acrylic resin, according to the groups: 1 and 5 - tooth with no treatment (control); 2 and 6 – tooth bur abrasion; 3 and 7 – tooth bur retention; and 4 and 8 – tooth monomer etch. Eighty specimens (n=10) were polymerized in bath cycle at 74ºC for 9 hours and deflasked after flask cooling. Specimen from groups 2, 4, 6 and 8 was submitted to simulated microwave disinfection in a microwave oven at 650W for 3 minutes. Impact strength test was performed with an Otto Wolpert-Werke machine (Charpy system) with an impact load of 40 kpcm. Fracture load value was transformed into impact strength as a function of the bond area (kfg/cm2). Collected data were submitted to ANOVA and Tukey’s test (α=.05) and results indicate that the simulated microwave disinfection decreased the impact strength in all treatments.
Key Words: Microwave disinfection, impact strength, tooth/acrylic resin adhesion, glossy ridge lap retention