Skip Navigation
National Institute of Environmental Health SciencesNational Institutes of Health
Increase text size Decrease text size Print this page

Specific Study

Word (http://tools.niehs.nih.gov/portfolio/sc/detail_doc.cfm?appl_id=7481955&ext=.doc)  Download Microsoft Word Viewer | Excel (http://tools.niehs.nih.gov/portfolio/sc/detail_xls.cfm?appl_id=7481955&ext=.xls)  Download Microsoft Excel Viewer | PDF (http://tools.niehs.nih.gov/portfolio/sc/detail_doc.cfm?appl_id=7481955&pdf=1&ext=.pdf)  Download Adobe Reader

Monolithic Reagentless Biosensor for Online Monitoring of Waterborne Pathogens

Principal Investigator
Su, Xiao-Li
Institute Receiving Award
Biodetection Instruments, Llc
Location
Fayetteville, AR
Grant Number
R43ES016699
Funding Organization
National Institute of Environmental Health Sciences
Award Funding Period
15 May 2008 to 14 May 2009
DESCRIPTION (provided by applicant): This Small Business Innovation Research Phase I project will develop a reagentless biosensor for online monitoring of microbial contaminants in drinking water. The biosensor is based on incorporating several newly emerging technologies into BioDetection Instruments' proprietary sensing platform. A novel monolithic column will be developed that encapsulates a unique sensing material that can specifically and directly detect an indicator bacterium with no need for the addition of any reagents. The monolithic column will be characterized by a hierarchical pore structure, high surface area, small diffusion path length, and low hydraulic resistance, which are favorable for streamlining the detection efficacy. Online monitoring of microbial contamination will be realized simply by pumping or injecting the water sample through the monolithic biosensing column along with on-column optical detection. In Phase II, the research will be extended to develop a multichannel biosensor system for online monitoring of multiple waterborne pathogens. The CDC reports that each year, 4 billion episodes of diarrhea result in an estimated 2 million deaths, and waterborne bacterial infections may account for as many as half of these episodes and deaths. The prevention of disease outbreaks relies on timely and efficient detection of disease-causing microorganisms. However, the detection of bacterial contaminants in drinking water still relies on cell growth-based methods, which are extremely time-consuming, typically requiring at least 24 hours and complicated multi-steps to confirm the analysis. Even current rapid methods such as ELISA and PCR still require enrichment of samples for 8-24 hours and take several hours to get only qualitative (positive/negative) results. Part of the challenge that faces both regulatory agencies and water plants, charged with protecting public health, is to find better, cost- effective, faster technologies for rapid detection of waterborne pathogens. PUBLIC HEALTH RELEVANCE: The proposed product will provide a reagentless assay for online monitoring of microbial contaminants in drinking water. Drinking water treatment facilities, bottled water and beverage manufacturers, as well as private well owners will benefit from the development of the proposed system. Using the proposed product, they will be able to monitor their water sources for microbial contaminations and promptly take corrective measures.
Crisp Terms/Key Words:
Science Code(s)/Area of Science(s)
Primary: 80 - SBIR/STTR
Program Administrator
Jerrold Heindel (heindelj@niehs.nih.gov)
USA.gov Department of Health & Human Services National Institutes of Health
This page URL: http://tools.niehs.nih.gov/portfolio/sc/detail.cfm
NIEHS website: http://www.niehs.nih.gov/
Email the Web Manager at webmanager@niehs.nih.gov
Last Reviewed: 21 August 2007