U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
04/11/2002 - 04/12/2002
** EVENT NUMBERS **
38844 38846 38847
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 38844 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: TEXAS DEPARTMENT OF HEALTH |NOTIFICATION DATE: 04/10/2002|
|LICENSEE: TECHNICAL WELDING LAB INC |NOTIFICATION TIME: 16:29[EDT]|
| CITY: HOUSTON REGION: 4 |EVENT DATE: 04/10/2002|
| COUNTY: HARRIS STATE: TX |EVENT TIME: 04:00[CDT]|
|LICENSE#: L-02187 AGREEMENT: Y |LAST UPDATE DATE: 04/10/2002|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |KRISS KENNEDY R4 |
| |JOHN HICKEY NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: TEXAS DEPT OF HEALTH BRC | |
| HQ OPS OFFICER: GERRY WAIG | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| OVEREXPOSURE TO GAMMA RADIATION |
| |
| The following is taken from a facsimile report: |
| |
| "A radiographer was [radiographing] welds on a vessel shooting with a 35 |
| curie Co-60 source and entered the vessel to change the source location |
| without cranking the source into the shielded position. The radiographer has |
| been taken for blood samples which will be repeated in 72 hours. Initial |
| calculations indicate a possible whole body exposure of 70 rems. Further |
| information forthcoming after investigation scheduled for May 14." |
| |
| The Texas Incident Number for this event is I-7882. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Other Nuclear Material |Event Number: 38846 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: BETHLEHAM STEEL |NOTIFICATION DATE: 04/11/2002|
|LICENSEE: BETHLEHAM STEEL |NOTIFICATION TIME: 09:41[EDT]|
| CITY: BETHLAHAM REGION: 1 |EVENT DATE: 04/10/2002|
| COUNTY: STATE: PA |EVENT TIME: 08:00[EDT]|
|LICENSE#: 37-01861-01 AGREEMENT: N |LAST UPDATE DATE: 04/11/2002|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |J. BRADLEY FEWELL R1 |
| |FRED BROWN NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: TONY LAMASTRA | |
| HQ OPS OFFICER: JOHN MacKINNON | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|IBBE 30.50(b)(2) SAFETY EQUIPMENT FAILUR| |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| SHUTTER FAILED TO OPEN ON A DMC/RADIOMETRIE GAUGE. |
| |
| A DMC/Radiometrie Model E6 source housing shutter failed to open. The |
| licensee swapped out the housing and will send the defective housing back to |
| Radiometrie, located in Gaithersburg, MD. The DMC/Radiometrie Model E6 |
| gauge contains one curie of Americium-241 which is used to measure the |
| thickness of thin sheets of steel. Bethlehem Steel Company has 30 or 40 of |
| these in the plant and this is the first time that a shutter on one of these |
| gauges has failed to open. The licensee stated that they have had these |
| gauges since the 1970's. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38847 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DRESDEN REGION: 3 |NOTIFICATION DATE: 04/11/2002|
| UNIT: [] [2] [3] STATE: IL |NOTIFICATION TIME: 13:42[EDT]|
| RXTYPE: [1] GE-1,[2] GE-3,[3] GE-3 |EVENT DATE: 04/11/2002|
+------------------------------------------------+EVENT TIME: 09:30[CDT]|
| NRC NOTIFIED BY: BILL HIGGINS |LAST UPDATE DATE: 04/11/2002|
| HQ OPS OFFICER: MIKE NORRIS +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |KENNETH RIEMER R3 |
|10 CFR SECTION: | |
|AIND 50.72(b)(3)(v)(D) ACCIDENT MITIGATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
| | |
|2 N Y 95 Power Operation |95 Power Operation |
|3 N Y 100 Power Operation |100 Power Operation |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| CONTROL ROOM VENTILATION SYSTEM INOPERABLE |
| |
| "At 1835 on 4/10/02, the Control Room Emergency Ventilation system |
| automatically repositioned to the 'purge' mode due to an apparent faulty |
| smoke detection circuit. It has been subsequently determined that while in |
| the 'purge' mode, the system is incapable of performing it's required safety |
| function. The Control Room Emergency Ventilation system is a single train |
| system utilized to mitigate the consequences of an accident and this event |
| is reportable under 10 CFR 50.72 (b) (3) (v) (D)." |
| |
| The NRC Resident Inspector has been notified. |
+------------------------------------------------------------------------------+