Home > Electronic Reading Room > Document Collections > Reports Associated with Events
> Event Notification Reports
> 2007
> June 19
Event Notification Report for June 19, 2007
U.S. Nuclear Regulatory Commission Operations Center
Event Reports For 06/18/2007 - 06/19/2007
** EVENT NUMBERS **
|
General Information or Other |
Event Number: 43422 |
Rep Org: IOWA DEPARTMENT OF PUBLIC HEALTH
Licensee: IOWA HEALTH - DES MOINES
Region: 3
City: DES MOINES State: IA
County:
License #: 0077-1-77-M1
Agreement: Y
Docket:
NRC Notified By: RANDY DAHLIN
HQ OPS Officer: JOE O'HARA
|
Notification Date: 06/14/2007
Notification Time: 14:54 [ET]
Event Date: 06/14/2007
Event Time: 10:30 [CDT]
Last Update Date: 06/14/2007
|
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
|
Person (Organization):
MONTE PHILLIPS (R3)
GREG MORELL (FSME)
|
Event Text
AGREEMENT STATE REPORT - POTENTIAL PERSONNEL OVEREXPOSURE
The licensee's RSO received a phone call from Landauer at 1030 this morning to report a badge which had a deep dose reading of 6437 milliRem, an eye dose reading of 6437 milliRem, and a shallow dose reading of 6400 milliRem. The badge was assigned to the Chief of Surgery for the licensee for the month of January 2006. The RSO is investigating the cause for the fifteen month delay (January 2006 till June 2007) in processing the badge. Landauer told the RSO that this was a "dynamic" exposure to the badge meaning that the badge was moving during the time period of exposure.
Iowa Item Number IA-070001. |
Power Reactor |
Event Number: 43428 |
Facility: SALEM
Region: 1 State: NJ
Unit: [1] [ ] [ ]
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: GARY MEEKINS
HQ OPS Officer: STEVE SANDIN
|
Notification Date: 06/18/2007
Notification Time: 12:50 [ET]
Event Date: 04/16/2007
Event Time: 22:23 [EDT]
Last Update Date: 06/18/2007
|
Emergency Class: NON EMERGENCY
10 CFR Section:
50.73(a)(1) - INVALID SPECIF SYSTEM ACTUATION
|
Person (Organization):
WILLIAM COOK (R1)
|
Unit |
SCRAM Code |
RX CRIT |
Initial PWR |
Initial RX Mode |
Current PWR |
Current RX Mode |
1 |
N |
N |
0 |
Hot Standby |
0 |
Hot Standby |
Event Text
INVALID ESF ACTUATION DURING REFUELING OUTAGE
"This telephone notification is provided in accordance with 10 CFR 50.73(a)(1) to report an invalid Engineered Safeguards Feature (ESF) actuation of the Auxiliary Feedwater(AFW) system reportable under 10 CFR 50.73(a)(2)(iv)(A).
"On April 16, 2007, at 2223 with Unit 1 in Mode 3, starting up from refueling outage 18, the 11 Steam Generator Feed Pump (SGFP) trip AFW Pump Auto Armed light extinguished unexpectedly and the Steam Generator (SG) sample valves 11 through 14-SS94 and SG Blowdown valves 11 through 14-GB4 closed. At the time, the 11 and 12 SGFPs were already tripped and the 11 and 12 Auxiliary Feedwater pumps were in service. No control room manipulations were in progress. A signal was generated to start the already in service AFW pumps.
"The invalid signal to start the AFW pumps was determined to be from a faulty SGFP alternate trip relay. The defective relay was replaced and the isolation signal was reset and retested satisfactorily.
"This event is reportable under 10 CFR 50.73(a)(2)(iv)(A) as an invalid ESF actuation and invalid system actuation.
"The licensee notified the NRC Resident Inspector." |
Fuel Cycle Facility |
Event Number: 43429 |
Facility: HONEYWELL INTERNATIONAL, INC.
RX Type: URANIUM HEXAFLUORIDE PRODUCTION
Comments: UF6 CONVERSION (DRY PROCESS)
Region: 2
City: METROPOLIS State: IL
County: MASSAC
License #: SUB-526
Agreement: Y
Docket: 04003392
NRC Notified By: LARRY BARSCALE
HQ OPS Officer: JOHN MacKINNON
|
Notification Date: 06/18/2007
Notification Time: 14:31 [ET]
Event Date: 06/18/2007
Event Time: 08:00 [CDT]
Last Update Date: 06/18/2007
|
Emergency Class: NON EMERGENCY
10 CFR Section:
INFORMATION ONLY
|
Person (Organization):
SCOTT SHAEFFER (R2)
GREG MORELL (FSME)
|
Event Text
DIGITAL CONTROL SYSTEM FAILED FOR UNKNOWN REASON
"At approximately 0800, lost all FMB control room monitors associated with Digital Control System (DCS). Several valves in UF6 process failed in unexpected position. No release and no exposures. System immediately put in a safe configuration. Root cause has begun and system will be kept in safe configuration for now (not restarted) until cause determined and corrected. This is a Courtesy Notification."
The NRC Resident Inspector and the NRC Regional Project Manager (Pelchat) were informed of this information call by the licensee. |
|