NRC Emergency Telecommunications System
June 30, 2000
Addressees
All holders of operating licenses for nuclear power reactors.
Intent
The U.S. Nuclear Regulatory Commission (NRC) is issuing
this regulatory issue summary (RIS) to inform addressees about impending
changes to the currently installed NRC Emergency Telecommunications System
(ETS). This RIS provides information on the process that will be followed
to modify the ETS at power reactor sites. This RIS also notifies addressees
about a voluntary, optional approach that would utilize corporate emergency
telecommunications systems in lieu of the NRC's dedicated circuits for
providing ETS service.
Background Information
The ETS provides seven communication functions to nuclear power reactor
emergency response facilities. These communication functions are considered
essential to the NRC response to an event at a nuclear power plant. The
ETS service is currently provided using direct access lines (DALs) to
the Federal Government's long distance network, FTS 2000. These dedicated
lines provide a direct connection to FTS 2000 and are not switched at
the local central office. This design feature is important because of
possible call volume saturation at the local telephone office during an
emergency. The FTS 2000 contract will expire in December 2000. The General
Services Administration has entered into follow-on contracts with MCI
WorldCom and Sprint for long distance service. The new service is called
FTS 2001, and NRC has selected MCI WorldCom as its FTS 2001 provider.
All current ETS service is included in the NRC plans for conversion to
FTS 2001, and the transition will occur between August and October of
2000.
In reviewing the options for a post-FTS 2000 ETS in
SECY-98-194, (Accession No. 9812110073) the NRC identified a potential
efficiency enhancement. The primary purpose of the DALs is to provide
access to long distance networks independent of the local telephone switch.
A consultant study and a survey of a representative cross section of licensee
sites indicate that most utilities have established corporate telecommunications
capabilities that already provide access to long distance networks without
having to go through a local telephone company switch. Therefore, ETS
functionality could be provided over corporate networks at minimal cost
to licensees; this measure would eliminate the large recurring costs associated
with the NRC's dedicated circuits.
Licensee costs would be restricted to costs associated with rerouting
the ETS circuits to the licensee's network. All long distance charges
would continue to be paid for by the Government.
Summary of Issue
The NRC requires reliable emergency telecommunications capability at
nuclear power plants in 10
CFR 50.47(b)(6) and 10
CFR Part 50, Appendix E. The telecommunications functions related
to communication between the NRC and nuclear power plant control rooms
and emergency response facilities are currently provided by the NRC utilizing
dedicated circuits to the FTS 2000 network. Because of the expiration
of the FTS 2000 contract, the ETS circuits will be transferred to the
follow-on FTS 2001 system using MCI WorldCom as the service provider.
The methodology for the service transition is discussed in Attachment
1.
In SECY-98-194, the NRC staff identified options for more efficiently
providing ETS services for nuclear power plants. The option supported
by the staff and approved by the Commission would involve the use of preexisting
licensee communications networks to provide access to long distance service
in a manner that would be independent of the local telephone switch. In
the original formulation of this plan, rulemaking was the anticipated
vehicle for accomplishing this goal. Consistent with the Commission's
decision on using industry initiatives in the regulatory process, the
staff has pursued the concept of a voluntary industry initiative to provide
ETS functionality using corporate communications networks through the
Nuclear Energy Institute
(NEI). A number of utilities have already expressed interest in the initiative.
The NRC staff will continue to support the optional use of licensee communications
networks to provide long distance access to ETS circuits in those cases
in which the licensee's network can route ETS calls to long distance service
independent of the local telephone switch. Details of this alternative
approach are provided in Attachment 2. Licensees that desire to implement
this option in lieu of the planned cutover to FTS 2001 should notify the
NRC ETS Project Officer, John Jolicoeur, through their NRR Project Manager
as soon as possible (preferably before July 30, 2000). Requests received
after July 30 will be accepted, but it may be too late to preempt the
installation of FTS 2001 service.
Please note that NRC staff will host a one-day workshop for those licensees
who are planning to implement the voluntary alternative described in Attachment
2 or are interested in obtaining additional information about this option
to make an informed decision. The workshop is tentatively scheduled to
be held on July 21, 2000, at the NRC Region III offices in Lisle, Illinois.
More detailed information concerning the workshop agenda and confirmation
of the date on which the workshop will be held is provided on the NRC
Home Page
. The NRC point of contact for prospective workshop attendees is John
Jolicoeur, who can be reached at 301-415-6383.
Emergency Plan Revisions
Emergency Plan revisions to reflect the changes made to licensee's emergency
telecommunications systems as a result of this RIS may be made in accordance
with 10 CFR 50.54(q) and need not be submitted to the NRC for prior approval.
Nevertheless, licensees are required under 10 CFR 50.54(q) to conduct
an analysis to determine that there has been no decrease in the effectiveness
of the plan as a result of these changes. Licensees should use this RIS
as a part of its basis for that determination.
Backfit Discussion
This RIS requires no action or written response. Any action on the part
of addressees to utilize corporate communications systems to provide ETS
circuits is strictly voluntary. Any modifications made in the transition
to FTS 2001 will be modifications to the NRC system. Since neither of
these items constitutes a backfit under 10
CFR 50.109, the staff did not perform a backfit analysis.
Federal Register Notification
A notice of opportunity for public comment on this RIS was not published
in the Federal Register because the NRC has worked closely with
NEI, industry representatives, and other stakeholders in an open public
forum since late 1998 on the need to upgrade the NRC ETS service. Furthermore,
the optional use of licensee communications networks to provide long distance
access to NRC ETS circuits, although a more efficient application of existing
communications capabilities, is strictly voluntary.
Paperwork Reduction Act Statement
This RIS contains a voluntary information collection that is subject
to the Paperwork Reduction Act of 1995 (22 U.S.C. 3501 et seq.). The NRC
may not conduct or sponsor, and a person is not required to respond to,
a collection of information unless it displays a currently valid Office
of Management and Budget (OMB) control number. The collection of this
information is covered by OMB clearance number 3150-0011, which expires
on September 30, 2000.
If there are any questions about this matter, please contact one of the
persons listed below.
|
/RA Charles E. Ader Acting for/
David B. Matthews, Director
Division of Regulatory Improvement Programs
Office of Nuclear Reactor Regulation
|
(ADAMS Accession Number ML003727812)
ATTACHMENT 1
RIS 2000-11
METHODOLOGY FOR NRC EMERGENCY TELECOMMUNICATIONS SYSTEM
(ETS)
TRANSITION FROM FTS 2000 TO FTS 2001
At those locations in which the use of licensee communications networks
is not an option or in which the licensee chooses not to implement the
option, the transition from the FTS 2000 (AT&T) network to the FTS
2001 (MCI) network will take place.
The three types of transition cutovers are as follows:
-
Parallel - All new facilities are utilized, including
the customer-provided equipment (CPE). There are no contingency options
needed for this type of cutover as all functions are run in parallel
before cutover.
-
Managed - The new facilities can only be installed
to a point within the user's building and not to the final termination
point or the CPE. The gaining vendor (MCI) is responsible for managing
all facets of the transition process. Contingency options that allow
the NRC to fall back on AT&T-provided facilities are necessary
if operational requirements are not met under the new service.
-
Coordinated - This type of cutover should only be
used when all other options have been exhausted. This option does
not allow for any contingency plans and is, therefore, the option
with the highest risk. The NRC ETS services will, for the most part,
utilize the managed cutover option. The use of a coordinated cutover
will only be implemented when the local exchange company (LEC) access
is unable to accommodate the installation of new services to the licensee's
main distribution frame (MDF). Timelines for the three types of cutovers
are listed at the end of this methodology.
The following methodology will be used to perform the ETS transition
in order to minimize the overall risk to the ETS transition:
Pre-Transition Testing: Before the local
exchange company's firm order confirmation (FOC) date for the delivery
of the new service, each of the NRC ETS functions should be tested by
the licensee to achieve the following:
-
Ensure the continuity of the licensee-provided inside wiring.
-
Minimize the impact of problem resolution during the transition process.
Transition Rotation: If there are limitations to the
availability of inside wiring with respect to the Control Room from the
MDF, each of the ETS functions will be rotated in the manner described
below using existing wiring, where possible. [Note: (1)
Each step of the transition will be tested as described under Testing
Methodology to ensure full duplex call completion and connectivity; (2)
At those locations in which the Emergency Offsite Facility (EOF) is fed
by different LEC facilities than the main plant, the Management Counterpart
Link (MCL) and the Operations Center Information Management System Local
Area Network (LAN) functions have been removed from the plant Technical
Support Center (TSC); (3) The Emergency Response Data System (ERDS) does
not exist at the EOF.]
-
When possible, a spare cable pair into the Control Room or the Emergency
Notification System (ENS) connection in the TSC shall be used to test
the MCI-provided ENS function. If a spare cable pair does not exist
or the TSC ENS use interferes with the operating ENS connection, one
of the counterpart links in the TSC shall be used to test the new
MCI ENS as described under Testing Methodology. Once the new MCI ENS
has been functionally tested and accepted, a managed transition of
the Control Room and TSC locations will be performed, followed by
another test and acceptance period.
-
The next function to be transitioned will be the Management Counterpart
Link (MCL) where applicable. The inside wiring from the MDF to the
TSC will be used to support the new MCL function. This practice will
leave the FTS 2000 MCL terminated at the MDF of the site.
-
The next function to be transitioned will be the Protective Measures
Counterpart Link (PMCL), which will be treated in the same manner
as the MCL function.
-
The Reactor Safety Counterpart Link (RSCL) will be similarly transitioned
next.
-
The Health Physics Network (HPN) function will be the next function
to be transitioned and tested.
-
The ERDS located in the licensee's computer room will then be transitioned.
-
The final ETS function to be transitioned is the Operations Center
Information Management System (LAN) function where applicable. If
required, the LAN will be transitioned the same as in step 2 above.
Testing Methodology: Testing as part of this
transition program is performed in two parts:
-
Pre-Transition Testing:
-
The licensee shall assist in the functional testing of each of
the ETS functions before transition to ensure the existing cable
path and the NRC CPE are functionally compliant with the service
requirements.
-
Functional testing is defined as the ability of the ETS function
to pass two-way call testing with the NRC Operations Center or other
designated test point.
-
For those functions that do not pass the functional testing, isolation
of the problem shall be conducted to ensure the continuity of the
licensee's cable path, terminations, and the NRC CPE
-
If the licensee's cable path and the NRC's CPE are not at fault,
the NRC ETS Technical Contact or designee shall be notified. The
NRC shall open a trouble ticket with the FTS 2000 vendor for resolution.
The NRC will be responsible for tracking the problem to resolution,
and the licensee will provide assistance as necessary to resolve
issues with the licensee's cable plant.
-
Once determined to be functional, the service will be declared
ready for transition.
-
New Service Acceptance Testing
-
The licensee shall assist the NRC in the functional testing of
each of the new ETS functions as they are declared ready for customer
acceptance testing by MCI.
-
The testing shall mirror the pre-transition testing, with non-functional
services being referred immediately to MCI for resolution
-
The NRC will be responsible for tracking the problem to resolution,
and the licensee will provide assistance as necessary to resolve
issues with the licensee's cable plant.
-
Once performed, the acceptance testing will recommence for verification
and acceptance of the new service.
Information Dissemination: MCI will be responsible
for providing the NRC and the licensee with circuit information and other
pertinent information related to each of the functions.
Licensee Responsibilities: The licensee will
be responsible for the following actions in support of this effort. It
is estimated that a half-day will be required per site to perform the
transition. A site is defined as a location at which all ETS functions
are fed from the same MDF. When the EOF is fed by different LEC facilities
than the main plant, the EOF is considered a separate site and an additional
half-day is required. These additional sites will be treated as a new
location for the purposes of the transition.
-
Making the cross-connect changes to accomplish the seven steps previously
mentioned during the transition process.
-
Assisting the NRC in making continuity and/or functionality testing
both before the installation as described in the pre-transition testing
phase and as part of the service acceptance testing after transition.
-
Making available, when feasible, one preexisting cable pair from
the MDF to the Control Room to support the new MCI ENS function as
identified in step 1 of the above-mentioned transition rotation description.
-
Providing the necessary resources to accomplish these three functions.
The NRC will utilize its existing list of licensee telecommunications
points of contact to support this effort. Questions regarding this matter
should be directed to the NRC ETS Technical Contact as identified in the
RIS. Specific questions regarding the FTS contract as it relates to the
ETS may be directed to one of the NRC FTS Transition Managers listed below:
Stan Wood, OCIO
301-415-7211
E-mail: sdw@nrc.gov
or
Benjamin Randall, Jr., OCIO
301-415-7250
E-mail: bwr@nrc.gov
ATTACHMENT 2
RIS 2000-11
VOLUNTARY ALTERNATIVE EMERGENCY TELECOMMUNICATIONS SYSTEM
(ETS) IMPLEMENTATION
The NRC currently provides reliable long distance telephone service to
nuclear power plant sites and remote Emergency Operations Facilities (EOFs)
for the following seven essential telecommunications functions:
-
Emergency Notification System (ENS) - The ENS is used for communication
between the NRC and the licensee. It is the normal circuit for event
reporting. It is also used to communicate reactor safety-related information
between the licensee and NRC during event response.
-
Health Physics Network (HPN) - The HPN is used for communication
of radiological and meteorological information between the licensee
and NRC during event response.
-
Reactor Safety Counterpart Link (RSCL) - The RSCL is used for communication
between NRC reactor safety team personnel at the site, regional office
and headquarters. The NRC Resident Inspector will normally communicate
on this circuit.
-
Protective Measures Counterpart Link (PMCL) - The PMCL is used for
communication between NRC protective measures team personnel at the
site, regional office, and headquarters.
-
Management Counterpart Link (MCL) - The MCL is used for communication
between the Site Team Leader (Director of Site Operations), the Headquarters
Executive Team, and the regional Base Team Manager.
-
Operations Center Local Area Network (LAN) line (OCL) - The OCL is
an analog phone line that is made available for accessing the NRC
Operations Center LAN using laptop computers with internal modems.
-
Emergency Response Data System (ERDS) - One analog phone line per
reactor unit is used for establishing the links between the licensee
computer systems and the NRC ERDS.
This service is currently provided using direct access lines (DALs) to
the Federal long distance service (FTS 2000), which is currently provided
by AT&T (as shown in Figure 1). During the accident at Three Mile
Island (TMI), telephone network congestion at the local telephone switch
serving the site prevented the establishment of communications between
the NRC and the site during the early phases of the accident. The current
ETS design using DALs to bypass the local telephone switch ensures that
emergency calls can be made even if the local telephone switch is congested
as it was in the TMI accident. The NRC is aware that most nuclear power
plants have corporate communications systems that do not depend on the
local telephone switch. In those cases, it may be feasible for licensees
to provide long distance access for all ETS functions.
The staff would consider licensee telecommunications systems acceptable
for the current ETS if they, like the DALs, do not rely on the local telephone
switch. This idea is illustrated conceptually in Figure 2. The NRC believes
that licensee telecommunications systems in many cases may be just as
reliable as the DALs, especially if they can reach the public switched
network (PSN) using independent means without going through the local
telephone switch. The importance of independence was illustrated by the
experience at Davis-Besse on June 24, 1998, when a tornado destroyed all
modes of telecommunications at the site except the licensee's corporate
microwave system. The Control Room operators had one circuit available
on that network, which was used to communicate with the NRC, which subsequently
notified the State authorities of the conditions on site. Examples of
acceptable paths for ETS access to long distance networks include the
following:
-
Land lines through an onsite private branch exchange (PBX) out to
the utility network
-
A microwave link to the PSN (e.g., through a corporate office)
-
A corporate fiber network
-
A satellite system
-
Any other telecommunications system or network that can provide long
distance access independent of the local telephone switch.
In order for licensees to provide ETS access, the current ETS telephones
or modems (for ERDS) would have to be re-routed to be carried on a corporate
system as previously described. This task could be accomplished by routing
the circuits through the site PBX. This measure would provide access to
multiple paths for call routing. Otherwise, the circuits could be re-routed
at the main distribution frame to the system selected for ETS services.
If directed through a toll-free (800/888) exchange, the cost of long distance
calls associated with ETS will be paid by the Government. In addition,
the NRC Operations Center accepts all calls (toll-free, commercial, or
collect) from any person reporting a nuclear emergency, regardless of
whether the ETS is involved.
For those plants with offsite EOFs, the possibility exists that adequate
communications facilities to implement this plan might only exist at one
of the two locations (i.e., either the plant or the EOF). In this case,
the methodology discussed above could be used at one of the two locations
and FTS 2001 DALs would be provided at the other.
The portable satellite telephones provided to each NRC Resident Inspector
will remain on site and will be made available for emergency reporting
in cases of total loss of telecommunications to the site.
Implementation of this voluntary initiative would entail the following:
-
Reviewing site telecommunications capabilities to verify that ETS
circuits can be provided access to long distance service by way of
existing site systems that are independent of the local telephone
switch that serves the site.
-
Notifying the NRC, in writing, of your intent to provide ETS services
utilizing corporate communications systems. Your notification should
describe the system proposed for providing ETS service and should
give a point of contact.
-
Rerouting of all current ETS service through the onsite telephone
system. Provide a list of the telephone numbers for the ETS circuits
that have been placed on corporate communication systems to the NRC
ETS Project Officer (John Jolicoeur, IRO).
-
Ensuring the ERDS and Operations Center LAN circuits are analog circuits.
-
Conducting tests of the newly installed circuits with the NRC Operations
Center.
-
Revising procedures, as appropriate, for operation with the newly
installed ETS service.
-
Providing dialing instructions at all ETS locations for each call
routing option available.
-
Making arrangements with the NRC Senior Resident Inspector to the
NRC's portable satellite telephones.
|