Escalated Enforcement Actions Issued to Reactor Licensees - M

Maine Yankee - Docket No. 050-00309

NRC Action Number(s) and
Facility Name
Action Type
(Severity) &
Civil Penalty
(if any)
Date
Issued
Description
EA-96-299
Maine Yankee Atomic Power Station
NOVs
10/8/1998 The violation stemmed from an Independent Safety Assessment of the Maine Yankee facility conducted in 1996 and Office of Investigations (OI) investigations from late 1995 through late 1997.

Massachusetts Institute of Technology - Docket No. 050-00020

NRC Action Number(s) and
Facility Name
Action Type
(Severity) &
Civil Penalty
(if any)
Date
Issued
Description
EA-03-155
Massachusetts Institute of Technology Research Reactor
NOV
(SL III)
10/31/2003 On October 31, 2003, a Notice of Violation was issued for a Severity Level III violation involving the failure of a reactor control operator to be present at the controls at all times during the operation of the facility, in that he was sleeping for approximately 30 minutes.
To top of page

McGuire 1 & 2 - Docket Nos. 050-00369; 050-00370

NRC Action Number(s) and
Facility Name
Action Type
(Severity) &
Civil Penalty
(if any)
Date
Issued
Description
EA-08-220
McGuire 1 & 2
NOV
(White)
10/27/2008 On October 27, 2008, a Notice of Violation was issued for a violation associated with a White Significance Determination Finding involving a violation of 10 CFR 50, Appendix B, Criterion XVI. The violation involved the failure to take adequate corrective action related to the service water strainer backwash system. Specifically, a plant modification implemented to address a macro-fouling concern associated with the service water strainers (1) utilized non-safety-related instrument air to support backwash operations, and (2) did not account for the impact on timely operator response following a safety injection signal or loss of instrument air. As a result, there was a lack of reasonable assurance that the service water system would have been capable of performing its safety-related function during a time of high fouling potential. The finding does not represent a current safety concern because temporary modifications and appropriate procedural changes have been made to address periods of potential macro-fouling.
EA-97-411
McGuire 1 & 2
NOV
(SL III)
09/26/1997 Unauthorized access.

EA-96-080 &
EA-96-100
McGuire

NOV
(SL III)
05/09/1996 Failure to maintain adequate procedures to ensure adequate freeze protection.
To top of page

Millstone 1, 2 & 3 - Docket Nos. 050-00245; 050-00336; 050-00423

NRC Action Number(s) and
Facility Name
Action Type
(Severity) &
Civil Penalty
(if any)
Date
Issued
Description
EA-02-014
Millstone 1
NOVCP
(SL II)

$288,000
06/25/2002 On June 25, 2002, a Notice of Violation and Proposed Imposition of Civil Penalty in the amount of $288,000 was issued for a Severity Level II violation involving the failure to: (1) keep adequate records of special nuclear material (SNM), (2) establish adequate procedures for control and accounting of SNM, and (3) conduct adequate physical inventories of SNM.
EA-00-236
Millstone 2
NOV
(White)
12/06/2000 On December 6, 2000, a Notice of Violation was issued for a violation associated with a White SDP finding involving the degraded condition of the turbine-driven auxiliary feedwater (TDAFW) pump. The violation was based on the licensee's failure to promptly correct a significant condition adverse to quality involving the speed control mechanism for the TDAFW.
EA-96-151
Millstone 2 & 3
NOV
(SL III)
05/25/1999 Violations associated with refueling operations and the spent fuel pool.
EA-98-325
Millstone 1, 2 & 3
NOV
(SL III)
04/06/1999 Discrimination against two supervisors.
EA-97-461
Millstone 1, 2 & 3
NOVCP
(SL II)

$ 88,000
03/09/1999 Violation involving the discrimination against two contractor employees.
EA-98-468
Millstone 2
NOV
(SL III)
02/18/1999 Violation of NRC requirements involving the auxiliary feedwater (AFW) system.
EA-98-179
Millstone 3
NOV
(SL III)
05/06/1998 Failure to maintain the post accident sampling system (PASS) operational within technical specification (TS) requirements.
EA-97-562
Millstone 3
NOVCP
(SL III)

$ 55,000
03/09/1998 Design problem with potential for air injection to charging and safety injection pumps.
EA-96-034
Millstone 2 & 3

NOVCP
(SL II)

$2,100,000
12/10/1997 Three Severity Level II and one Severity Level III problems consisting of multiple individual violations.
EA-97-104
Millstone 1, 2 & 3
NOVCP
(SL III)

$ 55,000
06/11/1997 Security issues.
EA-96-439
Millstone 1, 2 & 3
ORDER 10/24/1996 Order requiring independent oversight of company's implementation of resolution of station employee's safety concerns.
EA-96-059
Millstone 2 & 3
NOVCP
(SL III)

$100,000
06/04/1996 Discrimination against individual.