The purpose of the CLIIP is to streamline the license amendment review
process involving TSTF changes applicable to multiple plants. By using
a standardized process such as the CLIIP, the burden on an individual
licensee would be reduced by saving resources in preparing license amendment
applications and, at the same time, the NRC staff review process would
become more efficient. Each amendment application made as part of the
CLIIP will be processed and noticed int he Federal Register in accordance
with applicable rules and NRC Procedures, the CLIIP is further described
in the Regulatory Issue Summary 2000-06
.
The following TSTFs have been approved and are available for adoption by Licensees for their
specific plant TS. All TSTFs that were made available for adoption under CLIIP after February
2006 have Model SEs and Model Applications posted in the
Federal Register
.
Approved TSTF Traveler |
Title and ADAMS Notice of Availability (NOA), Model Application, Model SE, Other Models if Available |
Applicability -Based on Nuclear Supply System Vendor (Reactor Type) |
CLIIP Notice of Availability (NOA) from
Federal Register |
N/A |
Elimination of Typical License Condition Requiring Reporting of Violations of Section 2.C of Operating License
ML053010227
Example Application ML053070370
Previous Notice for Comment (including model SE) ML052350500 |
All plant designs |
70 Fed. Reg. 67202
(Nov. 4, 2005)
[TEXT]
[PDF] |
*358, R6
ML012690219 |
Missed Surveillance Requirements
ML012670082
Example application ML012670082 |
All plant designs |
66 Fed. Reg. 49714
(Sept. 28, 2001)
[TEXT]
[PDF] |
**359, R9
ML031190607 |
Increase Flexibility in MODE Restraints
ML030900056
Example application ML030900056 |
All plant designs |
68 Fed. Reg. 16579
(April 4,2003)
[TEXT]
[PDF] |
366
ML003734003 |
Elimination of Requirements for a Post Accident Sampling System (PASS)
ML003750475
Example application ML003754812 |
Westinghouse and Combustion Engineering Designs |
65 Fed. Reg. 65018
(Oct 31, 2000)
[TEXT]
[PDF] |
369, R1
ML040050211 |
Removal of Monthly Operating report and Occupational Radiation Exposure Report
ML041690439
Example Application ML041800481 |
All plant designs |
69 Fed. Reg. 35067
(June 23, 2004)
[TEXT]
[PDF] |
370
ML003771348 |
Increase Accumulator Completion Time
ML030640760
Example application ML030640794 |
Westinghouse |
68 Fed. Reg. 11880
(March 12, 2003)
[TEXT]
[PDF] |
372, R4
ML041200567 |
Addition of LCO 3.0.8 on the Inoperability of Snubbers
ML051160013
Example Application to adopt TSTF-372
ML051160013 |
All plant designs |
70 Fed. Reg. 23252
(April 4,2005)
[TEXT]
[PDF] |
373, R2
ML022460403 |
Extending the Completion Time for Inoperable Containment Isolation Valves
ML040490239
Example application ML040490270 |
Combustion Engineering |
69 Fed. Reg. 7986
(Feb. 20, 2004)
[TEXT]
[PDF] |
374, R0
ML011340449 |
Revision to TS 5.5.13 and Associated TS Bases for Diesel Fuel Oil ML071010061
Model safety evaluation (SE)
71
Fed. Reg. 9179
.
Model no significant hazards consideration (NSHC) determination.
71 Fed. Reg. 9179 .
Example
Application ML071010061 |
All |
71 Fed. Reg. 20735
(April 21, 2006)
[TEXT]
[PDF] |
404
ML011630155 |
Scram Discharge Volume Vent and Drain Valves ML030980809
Example application ML030980665 |
Boiling Water Reactors |
68 Fed. Reg. 18294
(April 15, 2003)
[TEXT]
[PDF] |
409, R2 ML033280006 |
Containment Spray System completion Time Extension (CE NPSD-1045-A) ML062930127 |
Combustion Engineering |
71 Fed. Reg. 65148
(Nov. 7, 2006)
[TEXT]
[PDF] |
412, R3 ML070100363 |
Provide Actions for One Steam Supply to Turbine Drive AFW/EFW Pump Inoperable ML071230105 |
Westinghouse |
72 Fed. Reg. 39089
(July 17, 2007)
[TEXT]
[PDF] |
413 ML011980194 |
Eliminate Post Accident Sampling Requirements for Boiling Water Reactors ML020780459
Example application
ML003754812 |
Boiling Water Reactors |
67 Fed. Reg. 13027
(March 20, 2002)
[TEXT]
[PDF] |
421 ML013390280 |
Extending the Inspection Interval for Reactor Coolant Pump Flywheels ML032890138
Example application
ML032890167 |
Westinghouse |
68 Fed. Reg. 60422
(Oct. 22, 2003)
[TEXT]
[PDF] |
422, R1
ML030270099 |
Risk-Informed Modification to Selected Action End States for CEOG PWR L051650153
Example Application to adopt TSTF-422
ML051650162
Previous Notice for Comment
ML051170362 |
Combustion Engineering Plants |
70 Fed. Reg. 38729
(July 5, 2005)
[TEXT]
[PDF] |
423, R0
ML032270250 |
Risk-Inform
Requirements Regarding Selected Required Action End States ML060760206
Previous Notice
for Comment (including model SE) ML051160056 |
Boiling Water Reactors |
71 Fed. Reg. 14726
(March 23, 2006)
[TEXT]
[PDF] |
427, R2 ML061240055 |
Allowance for Non Technical Specification Barrier Degradation on Supported System OPERABILITY ML062340423 |
All plant designs |
71 Fed. Reg. 58444
(Oct. 3, 2006)
[TEXT]
[PDF] |
442
ML021830167 |
Elimination of Post Accident Sampling Requirements for Babcock & Wilcox Co.
ML031270010
Example application ML031270010 |
Babcock & Wilcox Co. |
68 Fed. Reg. 25664
(May 13, 2003)
[TEXT]
[PDF] |
447, R1
ML032020007 |
Eliminate Hydrogen Recombiner Requirement, and Relax the Hydrogen and Oxygen Monitor Requirements
ML032600597
Example application
ML032600597 |
All plant
designs |
68 Fed. Reg. 55416
(Sept. 25, 2003)
[TEXT]
[PDF] |
448, R3
ML062210095
ML063630467 |
Control Room Habitability
ML063460558
Model application
ML063460558
ML070330657 |
All plant designs |
72 Fed. Reg. 2022
(January 17, 2007)
[TEXT]
[PDF] |
449, R4
ML051090200 |
Steam Generator Tube Integrity
ML051160106
Example Application to adopt TSTF-449 ML061040351
Previous Notice for Comment (Including Model SE)
ML050310015
Simplified Model SE ML070300547 |
Pressurized Water Reactors |
70 Fed. Reg. 24126
(May 6, 2005)
[TEXT]
[PDF] |
454,R1
ML052700153 |
Increase PCIV [Primary Containment Isolation Valves] Completion Times
ML053070451
Example Application ML053070410 |
Boiling Water Reactors |
70 Fed. Reg. 73802
(Dec. 13, 2005)
[TEXT]
[PDF] |
460
ML033350006 |
Control Rod Scram Time Testing Frequency ML042250224
Example Application ML061320010 |
Boiling Water Reactors |
69 Fed. Reg. 51864
(Aug. 23, 2004)
[TEXT]
[PDF] |
475, R1
ML071420428 |
Control Rod Notch Testing Frequency and SRM Insert Control Rod Action ML073050017 |
All plant designs |
72 Fed. Reg. 63935
(Nov. 13, 2007)
[TEXT]
[PDF] |
476, R1 ML070090561 |
Improved BPWS Control Rod Insertion Process (NEDO-33091) ML070880921 |
Boiling Water Reactors |
72 Fed. Reg. 29004
(May 23, 2007)
[TEXT]
[PDF] |
477, R3 ML062510321 |
Add Action for Two Inoperable Control Room AC Subsystems ML070510176 |
Boiling Water Reactors |
72 Fed. Reg. 14143
(March 26, 2007)
[TEXT]
[PDF] |
478, R2
ML071920140 |
BWR Technical Specification Changes that Implement the Revised Rule for Combustible Gas Control
ML073170138 |
Boiling Water Reactors |
72 Fed. Reg. 65610
(Nov. 21, 2007)
[TEXT]
[PDF] |
484
ML052930102 |
Use of TS 3.10.1 for Scram Time Testing Activities ML062760109
Example Application ML062990425 |
Boiling Water Reactors |
Model SE 71 Fed. Reg. 63050 (Oct. 27, 2006)
[TEXT]
[PDF]
Model Application 71 Fed. Reg. 68642 (Nov. 27, 2006)
[TEXT]
[PDF] |
486, R2 ML071300267 |
Revise MTC Surveillance for Startup Test Activity Reduction (STAR) Program (WCAP-16011) ML072400538 |
Westinghouse |
72 Fed. Reg. 51259
(Sep. 6, 2007)
[TEXT]
[PDF] |
487, R1 ML071240259 |
Relocate DNB Parameters to the COLR ML071230184 |
Westinghouse |
72 Fed. Reg. 31108
(June 5, 2007)
[TEXT]
[PDF] |
490,R0 ML052630462 |
Deletion of E Bar definition and revision to RCS specific activity
ML070250176
Example Application ML070250176 |
Pressurized Water Reactors |
72 Fed. Reg. 12217 (March 15, 2007)
[TEXT]
[PDF] |
491,R2
ML061500078 |
Removal of Main Steam and Main Feedwater Valve Isolation Times from TECHNICAL SPECIFICATIONS ML063390370
Example Application ML063390370 |
Pressurized Water Reactors |
Model SE
71 Fed. Reg. 58884
(Oct. 5, 2006)
[TEXT] [PDF]
Model Application
71 Fed. Reg. 78472
(Dec. 29, 2006)
[TEXT] [PDF] |
511, R0
ML082610292 |
Eliminate Working Hour Restrictions from TS 5.2.2 to Support Compliance with 10 CFR Part 26 ML083180519 |
All plant designs |
Vol 73 FR 79923
(Dec. 30, 2008)
[TEXT] [PDF] |