Argonne Model Boiler Facility Topical Report (NUREG/CR-6880)
On this page:
Download complete document
The following links on this page are to documents in Adobe Portable Document
Format (PDF). See our Plugins, Viewers, and
Other Tools page for more information. For successful viewing of PDF documents on our site please be sure to use the latest version of Adobe.
Publication Information
Manuscript Completed: May 2005
Date Published: July 2005
Prepared by
K. E. Kasza, J. J. Oras, B. L. Fisher,
J. Y. Park, J. E. Franklin, and W. J. Shack
Argonne National Laboratory
9700 South Cass Avenue
Argonne, IL 60439
J. Davis, NRC Project Manager
Prepared for
Division of Engineering Technology
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001
NRC Job Code Y6588
Availability
Notice
Abstract
A model boiler has been developed to simulate prototypical thermal hydraulics and bulk chemistry conditions on the secondary side of steam generators in pressurized water reactors. The facility produces prototypic crevice conditions by simultaneously matching both crevice heat flux and temperature. The model boiler is a simplified design involving no circulating primary or secondary loops. It is designed for unattended long-term operation. This report describes the design, operation, and shakedown testing of the model boiler. Stable operation with primary and secondary temperatures/pressures reasonably prototypical of actual steam generators and yielding prototypic across-tube heat fluxes has been demonstrated using multiple Alloy 600 tube test assemblies [0.30-m (12-in.) long, 22.2-mm (7/8-in.) diameter]. The facility secondary chamber has been fitted with steam-generator tube/instrumented crevice simulator ring test assemblies, and the first chemical hideout benchmarking tests involving 20ppm NaOH additions to the bulk secondary water have been initiated. The model boiler will be used to better determine the physical and chemical conditions in crevices in the secondary side of steam generators as a function of bulk water chemistry and the thermal hydraulic conditions expected at different locations in steam generators. The crevice chemistry and physical conditions established from the model boiler studies will be used in other laboratory test systems to establish stress corrosion cracking (SCC) initiation times and crack growth rates of Alloy 600 and 690 specimens. This crack initiation and growth rate data will be used to develop predictive models. Once the predictive models are developed, the model boiler could be used to experimentally validate the models.
|