Light Water Reactor Hydrogen Manual
(NUREG/CR-2726)
On this page:
Download complete document
The following links on this page are to documents in Adobe Portable Document
Format (PDF). See our Plugins, Viewers, and
Other Tools page for more information. For successful viewing of PDF documents on our site please be sure to use the latest version of Adobe.
Publication Information
Manuscript Completed: January, 1983
Date Published: June, 1983
Sandia National Laboratories
Albuquerque, NM 87185
Operated By Sandia Corporation
for the
U. S. Department of Energy
Prepared for Division of Accident Evaluation
Office of Nuclear Regulatory Research
U. S. Nuclear Regulatory Commission
Washington, D.C. 20555
Under Memorandum of Understanding DOE 40-550-75
NRC FIN No. A 1246
Availability
Notice
Abstract
A manual concerning the behavior of hydrogen in light water reactors has
been prepared. Both normal operations and accident situations are addressed.
Topics considered include hydrogen generation, transport and mixing, detection,
and combustion, and mitigation. Basic physical and chemical phenomena are
described, and plant-specific examples are provided where appropriate. A wide
variety of readers, including operators, designers, and NRC staff, will find
parts of this manual useful. Different sections are written at different
levels, according to the most likely audience. The manual is not intended to provide specific plant procedures, but rather, to provide general guidance
that may assist in the development of such procedures.
|