Search Options | ||||
Index | Site Map | FAQ | Facility Info | Reading Rm | New | Help | Glossary | Contact Us |
Licensee's General Comments: none
Unplanned Scrams per 7000 Critical Hrs | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Unplanned scrams | 2.0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Critical hours | 2128.8 | 2159.0 | 2184.0 | 2208.0 | 1503.8 | 2183.0 | 2184.0 | 2208.0 |
Indicator value | 1.6 | 1.6 | 1.6 | 1.6 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Unplanned Power Changes per 7000 Critical Hrs | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Unplanned power changes | 0 | 0 | 0 | 0 | 1.0 | 0 | 0 | 0 |
Critical hours | 2128.8 | 2159.0 | 2184.0 | 2208.0 | 1503.8 | 2183.0 | 2184.0 | 2208.0 |
Indicator value | 0.8 | 0 | 0 | 0 | 0.9 | 0.9 | 0.9 | 0.9 |
Licensee Comments: none
Unplanned Scrams with Complications | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Scrams with complications | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
Licensee Comments: none
Safety System Functional Failures (PWR) | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Safety System Functional Failures | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Mitigating Systems Performance Index, Emergency AC Power System | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
UAI (ΔCDF) | -4.90E-08 | -9.50E-08 | -1.40E-07 | -1.70E-07 | -1.60E-07 | -1.20E-07 | 7.10E-08 | 7.40E-08 |
URI (ΔCDF) | -8.80E-07 | -8.80E-07 | -8.70E-07 | -8.70E-07 | -8.80E-07 | -9.00E-07 | -9.10E-07 | -9.10E-07 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -9.29E-07 | -9.75E-07 | -1.01E-06 | -1.04E-06 | -1.04E-06 | -1.02E-06 | -8.39E-07 | -8.36E-07 |
Licensee Comments: none
Mitigating Systems Performance Index, High Pressure Injection System | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
UAI (ΔCDF) | 5.90E-07 | -7.60E-08 | -1.40E-07 | -1.50E-07 | -1.30E-07 | 2.10E-07 | 2.10E-07 | 2.10E-08 |
URI (ΔCDF) | -2.20E-07 | -2.20E-07 | -2.20E-07 | -2.20E-07 | -2.20E-07 | -2.20E-07 | -2.20E-07 | -2.20E-07 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | 3.70E-07 | -2.96E-07 | -3.60E-07 | -3.70E-07 | -3.50E-07 | -1.00E-08 | -1.00E-08 | -1.99E-07 |
Licensee Comments: none
Mitigating Systems Performance Index, Heat Removal System | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
UAI (ΔCDF) | -9.90E-09 | -9.90E-09 | 2.40E-08 | 2.50E-08 | 2.20E-08 | 1.10E-08 | 6.70E-09 | 1.40E-09 |
URI (ΔCDF) | -1.20E-08 | -1.20E-08 | -1.20E-08 | -1.20E-08 | -1.20E-08 | -1.20E-08 | -1.20E-08 | -1.20E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -2.19E-08 | -2.19E-08 | 1.20E-08 | 1.30E-08 | 1.00E-08 | -1.00E-09 | -5.30E-09 | -1.06E-08 |
Licensee Comments: none
Mitigating Systems Performance Index, Residual Heat Removal System | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
UAI (ΔCDF) | -5.00E-08 | 2.30E-08 | -1.90E-08 | -2.00E-08 | -8.20E-09 | -1.10E-08 | -1.30E-08 | -1.20E-08 |
URI (ΔCDF) | -9.70E-07 | -9.70E-07 | -9.70E-07 | -9.70E-07 | -9.70E-07 | -9.70E-07 | -9.70E-07 | -9.70E-07 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -1.02E-06 | -9.47E-07 | -9.89E-07 | -9.90E-07 | -9.78E-07 | -9.81E-07 | -9.83E-07 | -9.82E-07 |
Licensee Comments: none
Mitigating Systems Performance Index, Cooling Water Systems | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
UAI (ΔCDF) | 4.00E-07 | 2.20E-07 | 2.30E-07 | 2.20E-07 | 2.30E-07 | 4.70E-07 | 5.20E-07 | 5.60E-07 |
URI (ΔCDF) | -3.70E-06 | -3.70E-06 | -3.70E-06 | -3.70E-06 | -3.70E-06 | -1.70E-06 | -1.70E-06 | -1.60E-06 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -3.30E-06 | -3.48E-06 | -3.47E-06 | -3.48E-06 | -3.47E-06 | -1.23E-06 | -1.18E-06 | -1.04E-06 |
Licensee Comments: none
Reactor Coolant System Activity | 10/06 | 11/06 | 12/06 | 1/07 | 2/07 | 3/07 | 4/07 | 5/07 | 6/07 | 7/07 | 8/07 | 9/07 |
Maximum activity | 0.003590 | 0.003550 | 0.004240 | 0.004070 | 0.004260 | 0.004540 | 0.004440 | 0.004350 | 0.004910 | 0.004440 | 0.004150 | 0.004400 |
Technical specification limit | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 |
Indicator value | 1.0 | 1.0 | 1.2 | 1.2 | 1.2 | 1.3 | 1.3 | 1.2 | 1.4 | 1.3 | 1.2 | 1.3 |
Reactor Coolant System Activity | 10/07 | 11/07 | 12/07 | 1/08 | 2/08 | 3/08 | 4/08 | 5/08 | 6/08 | 7/08 | 8/08 | 9/08 |
Maximum activity | 0.004710 | 0.001680 | 0.002100 | 0.001940 | 0.002230 | 0.002140 | 0.002220 | 0.002380 | 0.002470 | 0.002770 | 0.002700 | 0.002860 |
Technical specification limit | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 | 0.4 |
Indicator value | 1.3 | 0.5 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.7 | 0.7 | 0.8 | 0.8 | 0.8 |
Licensee Comments: none
Reactor Coolant System Leakage | 10/06 | 11/06 | 12/06 | 1/07 | 2/07 | 3/07 | 4/07 | 5/07 | 6/07 | 7/07 | 8/07 | 9/07 |
Maximum leakage | 0.096 | 0.083 | 0.167 | 0.087 | 0.123 | 0.106 | 0.076 | 0.075 | 0.096 | 0.076 | 0.079 | 0.074 |
Technical specification limit | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 |
Indicator value | 1.0 | 0.8 | 1.7 | 0.9 | 1.2 | 1.1 | 0.8 | 0.8 | 1.0 | 0.8 | 0.8 | 0.7 |
Reactor Coolant System Leakage | 10/07 | 11/07 | 12/07 | 1/08 | 2/08 | 3/08 | 4/08 | 5/08 | 6/08 | 7/08 | 8/08 | 9/08 |
Maximum leakage | 0.060 | 0.335 | 0.106 | 0.108 | 0.108 | 0.171 | 0.092 | 0.103 | 0.077 | 0.131 | 0.093 | 0.084 |
Technical specification limit | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 |
Indicator value | 0.6 | 3.4 | 1.1 | 1.1 | 1.1 | 1.7 | 0.9 | 1.0 | 0.8 | 1.3 | 0.9 | 0.8 |
Licensee Comments: none
Drill/Exercise Performance | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Successful opportunities | 211.0 | 65.0 | 15.0 | 38.0 | 3.0 | 62.0 | 29.0 | 24.0 |
Total opportunities | 214.0 | 66.0 | 16.0 | 40.0 | 4.0 | 63.0 | 30.0 | 24.0 |
Indicator value | 96.7% | 96.8% | 97.2% | 97.5% | 97.5% | 97.7% | 97.5% | 97.8% |
Licensee Comments: none
ERO Drill Participation | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Participating Key personnel | 59.0 | 61.0 | 57.0 | 62.0 | 61.0 | 58.0 | 56.0 | 60.0 |
Total Key personnel | 59.0 | 61.0 | 57.0 | 62.0 | 61.0 | 58.0 | 56.0 | 61.0 |
Indicator value | 100.0% | 100.0% | 100.0% | 100.0% | 100.0% | 100.0% | 100.0% | 98.4% |
Licensee Comments: none
Alert & Notification System | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Successful siren-tests | 1248 | 1246 | 1244 | 1245 | 1245 | 1248 | 1247 | 1246 |
Total sirens-tests | 1248 | 1248 | 1248 | 1248 | 1247 | 1248 | 1248 | 1248 |
Indicator value | 99.4% | 99.3% | 99.8% | 99.8% | 99.8% | 99.8% | 99.9% | 99.9% |
Licensee Comments: none
Occupational Exposure Control Effectiveness | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
High radiation area occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Very high radiation area occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Unintended exposure occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
RETS/ODCM Radiological Effluent | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
RETS/ODCM occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Action Matrix Summary | Inspection Findings Summary | PI Summary | Reactor Oversight Process
Last Modified: November 26, 2008