Licensee's General Comments: none
Unplanned Scrams per 7000 Critical Hrs | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Unplanned scrams | 0 | 0 | 1.0 | 1.0 | 0 | 0 | 1.0 | 0 |
Critical hours | 1708.2 | 2159.0 | 2072.7 | 2193.6 | 2209.0 | 1699.0 | 1228.5 | 2208.0 |
Indicator value | 0.8 | 0.8 | 1.7 | 1.7 | 1.6 | 1.7 | 1.9 | 1.0 |
Licensee Comments: none
Unplanned Power Changes per 7000 Critical Hrs | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Unplanned power changes | 0 | 0 | 0 | 0 | 0 | 0 | 1.0 | 0 |
Critical hours | 1708.2 | 2159.0 | 2072.7 | 2193.6 | 2209.0 | 1699.0 | 1228.5 | 2208.0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 1.0 | 1.0 |
Licensee Comments: none
Unplanned Scrams with Complications | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Scrams with complications | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
Licensee Comments: none
Safety System Functional Failures (PWR) | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Safety System Functional Failures | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Mitigating Systems Performance Index, Emergency AC Power System | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
UAI (ΔCDF) | -1.00E-06 | -1.00E-06 | -1.00E-06 | -1.00E-06 | -1.00E-06 | -1.00E-06 | -4.40E-07 | -4.40E-07 |
URI (ΔCDF) | -9.10E-06 | -8.90E-06 | -8.70E-06 | -8.40E-06 | -8.90E-06 | -7.60E-06 | -4.60E-06 | -4.50E-06 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -1.01E-05 | -9.90E-06 | -9.70E-06 | -9.40E-06 | -9.90E-06 | -8.60E-06 | -5.04E-06 | -4.94E-06 |
Licensee Comments: none
Mitigating Systems Performance Index, High Pressure Injection System | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
UAI (ΔCDF) | -9.80E-08 | -9.80E-08 | -9.80E-08 | -9.80E-08 | -9.80E-08 | -9.80E-08 | -7.10E-10 | -7.10E-10 |
URI (ΔCDF) | -4.70E-08 | -4.70E-08 | -4.70E-08 | -4.70E-08 | -4.70E-08 | -4.60E-08 | -1.20E-07 | -1.20E-07 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -1.45E-07 | -1.45E-07 | -1.45E-07 | -1.45E-07 | -1.45E-07 | -1.44E-07 | -1.21E-07 | -1.21E-07 |
Licensee Comments: none
Mitigating Systems Performance Index, Heat Removal System | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
UAI (ΔCDF) | -8.00E-08 | -8.00E-08 | -8.00E-08 | -8.30E-08 | -8.30E-08 | -8.30E-08 | -4.70E-08 | -4.70E-08 |
URI (ΔCDF) | -2.60E-07 | -2.50E-07 | -2.50E-07 | -3.00E-07 | -2.90E-07 | -2.90E-07 | -2.30E-07 | -2.20E-07 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -3.40E-07 | -3.30E-07 | -3.30E-07 | -3.83E-07 | -3.73E-07 | -3.73E-07 | -2.77E-07 | -2.67E-07 |
Licensee Comments: none
Mitigating Systems Performance Index, Residual Heat Removal System | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
UAI (ΔCDF) | 1.60E-08 | 1.50E-08 | 1.30E-08 | 1.20E-08 | 1.10E-08 | -3.60E-08 | -1.50E-08 | -1.60E-08 |
URI (ΔCDF) | -1.30E-07 | -1.30E-07 | -1.20E-07 | -1.20E-07 | -1.10E-07 | -1.20E-07 | -5.90E-08 | -5.80E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -1.14E-07 | -1.15E-07 | -1.07E-07 | -1.08E-07 | -9.90E-08 | -1.56E-07 | -7.40E-08 | -7.40E-08 |
Licensee Comments: none
Mitigating Systems Performance Index, Cooling Water Systems | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
UAI (ΔCDF) | 9.10E-07 | 8.60E-07 | 8.40E-07 | 8.20E-07 | 8.40E-07 | 8.60E-07 | -1.00E-07 | -1.40E-07 |
URI (ΔCDF) | -1.00E-06 | -1.00E-06 | -1.00E-06 | -2.80E-07 | -2.80E-07 | -2.80E-07 | -1.60E-07 | -1.60E-07 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -9.00E-08 | -1.40E-07 | -1.60E-07 | 5.40E-07 | 5.60E-07 | 5.80E-07 | -2.60E-07 | -3.00E-07 |
Licensee Comments:
2Q/08: Changed MSPI coefficients based on revisions to PRA and MSPI Basis Document, effective 2Q08.
Reactor Coolant System Activity | 10/06 | 11/06 | 12/06 | 1/07 | 2/07 | 3/07 | 4/07 | 5/07 | 6/07 | 7/07 | 8/07 | 9/07 |
Maximum activity | 0.002006 | 0.001196 | 0.000720 | 0.000780 | 0.001123 | 0.000861 | 0.000862 | 0.001130 | 0.000906 | 0.000963 | 0.001030 | 0.001060 |
Technical specification limit | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
Indicator value | 0.2 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 |
Reactor Coolant System Activity | 10/07 | 11/07 | 12/07 | 1/08 | 2/08 | 3/08 | 4/08 | 5/08 | 6/08 | 7/08 | 8/08 | 9/08 |
Maximum activity | 0.001075 | 0.001144 | 0.001109 | 0.001260 | 0.001320 | 0.001110 | 0.001110 | 0.001110 | 0.000549 | 0.000423 | 0.000441 | 0.000428 |
Technical specification limit | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
Indicator value | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0 | 0 | 0 |
Licensee Comments: none
Reactor Coolant System Leakage | 10/06 | 11/06 | 12/06 | 1/07 | 2/07 | 3/07 | 4/07 | 5/07 | 6/07 | 7/07 | 8/07 | 9/07 |
Maximum leakage | 0 | 0 | 0.045 | 0.090 | 0.030 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Technical specification limit | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 |
Indicator value | 0 | 0 | 0.5 | 0.9 | 0.3 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Reactor Coolant System Leakage | 10/07 | 11/07 | 12/07 | 1/08 | 2/08 | 3/08 | 4/08 | 5/08 | 6/08 | 7/08 | 8/08 | 9/08 |
Maximum leakage | 0 | 0 | 0 | 0 | 0 | 0.066 | 0 | 0.070 | 0.050 | 0.070 | 0 | 0 |
Technical specification limit | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0.7 | 0 | 0.7 | 0.5 | 0.7 | 0 | 0 |
Licensee Comments: none
Drill/Exercise Performance | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Successful opportunities | 88.0 | 24.0 | 20.0 | 50.0 | 56.0 | 32.0 | 35.0 | 67.0 |
Total opportunities | 91.0 | 24.0 | 20.0 | 52.0 | 58.0 | 34.0 | 36.0 | 70.0 |
Indicator value | 96.7% | 97.0% | 97.4% | 97.1% | 97.3% | 96.7% | 97.0% | 96.6% |
Licensee Comments: none
ERO Drill Participation | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Participating Key personnel | 112.0 | 106.0 | 113.0 | 113.0 | 115.0 | 109.0 | 109.0 | 120.0 |
Total Key personnel | 112.0 | 110.0 | 116.0 | 118.0 | 115.0 | 111.0 | 116.0 | 121.0 |
Indicator value | 100.0% | 96.4% | 97.4% | 95.8% | 100.0% | 98.2% | 94.0% | 99.2% |
Licensee Comments: none
Alert & Notification System | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Successful siren-tests | 496 | 497 | 497 | 496 | 497 | 497 | 497 | 497 |
Total sirens-tests | 497 | 497 | 497 | 497 | 497 | 497 | 497 | 497 |
Indicator value | 99.0% | 99.3% | 99.3% | 99.9% | 99.9% | 99.9% | 99.9% | 100.0% |
Licensee Comments: none
Occupational Exposure Control Effectiveness | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
High radiation area occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Very high radiation area occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Unintended exposure occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
RETS/ODCM Radiological Effluent | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
RETS/ODCM occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Action Matrix Summary |
Inspection Findings Summary |
PI Summary |