Licensee's General Comments: Some SI and RHR unavailability hours for previous reporting periods were revised to include all applicable hours after a verification review determined some unavailability hours for SI and RHR had not been included based on component tag out times and actual component availability. Total unavailable hours added covering the period 3Q06-2Q08 for the follow components: Unit 2: 21 SI=1.08, 22 SI=1.78, 23 SI=6.57 21 RHR=1.18, 22 RHR=3.5
Unplanned Scrams per 7000 Critical Hrs | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Unplanned scrams | 1.0 | 1.0 | 0 | 0 | 0 | 1.0 | 1.0 | 0 |
Critical hours | 2186.0 | 2144.9 | 2184.0 | 2208.0 | 2209.0 | 1989.3 | 1724.9 | 2208.0 |
Indicator value | 2.6 | 2.6 | 2.4 | 1.6 | 0.8 | 0.8 | 1.7 | 1.7 |
Licensee Comments: none
Unplanned Power Changes per 7000 Critical Hrs | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Unplanned power changes | 1.0 | 0 | 1.0 | 0 | 0 | 0 | 0 | 0 |
Critical hours | 2186.0 | 2144.9 | 2184.0 | 2208.0 | 2209.0 | 1989.3 | 1724.9 | 2208.0 |
Indicator value | 1.8 | 1.8 | 2.4 | 1.6 | 0.8 | 0.8 | 0 | 0 |
Licensee Comments: none
Unplanned Scrams with Complications | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Scrams with complications | 0 | 1.0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 1.0 | 1.0 | 0.0 | 0.0 | 0.0 |
Licensee Comments: none
Safety System Functional Failures (PWR) | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Safety System Functional Failures | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
Mitigating Systems Performance Index, Emergency AC Power System | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
UAI (ΔCDF) | 6.30E-07 | 6.40E-07 | 7.60E-07 | 7.90E-07 | 4.90E-07 | 5.30E-07 | 6.70E-07 | 6.30E-07 |
URI (ΔCDF) | -3.70E-06 | -3.70E-06 | -3.70E-06 | -3.60E-06 | -3.80E-06 | -3.90E-06 | -3.90E-06 | -3.90E-06 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -3.07E-06 | -3.06E-06 | -2.94E-06 | -2.81E-06 | -3.31E-06 | -3.37E-06 | -3.23E-06 | -3.27E-06 |
Licensee Comments: none
Mitigating Systems Performance Index, High Pressure Injection System | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
UAI (ΔCDF) | 3.20E-10 | 3.00E-10 | 2.40E-10 | 1.70E-10 | 4.40E-11 | -9.80E-11 | -1.20E-10 | -1.20E-10 |
URI (ΔCDF) | 3.60E-09 | 3.60E-09 | 3.60E-09 | 3.60E-09 | 2.80E-09 | 2.80E-09 | 2.80E-09 | 2.80E-09 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | 3.92E-09 | 3.90E-09 | 3.84E-09 | 3.77E-09 | 2.84E-09 | 2.70E-09 | 2.68E-09 | 2.68E-09 |
Licensee Comments: none
Mitigating Systems Performance Index, Heat Removal System | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
UAI (ΔCDF) | 3.50E-07 | 3.30E-07 | 2.70E-07 | 2.50E-07 | 2.30E-07 | 1.90E-07 | 2.40E-07 | 4.10E-07 |
URI (ΔCDF) | -1.20E-06 | -1.20E-06 | -1.20E-06 | -1.10E-06 | -1.10E-06 | -1.20E-06 | -1.20E-06 | -1.20E-06 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -8.50E-07 | -8.70E-07 | -9.30E-07 | -8.50E-07 | -8.70E-07 | -1.01E-06 | -9.60E-07 | -7.90E-07 |
Licensee Comments: none
Mitigating Systems Performance Index, Residual Heat Removal System | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
UAI (ΔCDF) | -5.60E-09 | -5.60E-09 | -5.60E-09 | -5.60E-09 | -1.30E-09 | -1.10E-09 | -9.90E-10 | -9.60E-10 |
URI (ΔCDF) | 5.40E-09 | 4.30E-08 | 4.30E-08 | 4.30E-08 | 3.50E-08 | 9.10E-09 | 7.30E-09 | 8.00E-09 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | -2.00E-10 | 3.74E-08 | 3.74E-08 | 3.74E-08 | 3.37E-08 | 8.00E-09 | 6.31E-09 | 7.04E-09 |
Licensee Comments: none
Mitigating Systems Performance Index, Cooling Water Systems | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
UAI (ΔCDF) | 2.60E-09 | 2.50E-09 | -1.00E-08 | -9.80E-09 | -7.90E-09 | -6.00E-09 | 3.70E-08 | 4.20E-08 |
URI (ΔCDF) | 4.70E-08 | 4.70E-08 | 5.80E-08 | 5.70E-08 | 4.90E-08 | 4.60E-08 | 7.10E-08 | 7.10E-08 |
PLE | NO | NO | NO | NO | NO | NO | NO | NO |
Indicator value | 4.96E-08 | 4.95E-08 | 4.80E-08 | 4.72E-08 | 4.11E-08 | 4.00E-08 | 1.08E-07 | 1.13E-07 |
Licensee Comments: none
Reactor Coolant System Activity | 10/06 | 11/06 | 12/06 | 1/07 | 2/07 | 3/07 | 4/07 | 5/07 | 6/07 | 7/07 | 8/07 | 9/07 |
Maximum activity | 0.001410 | 0.001480 | 0.001600 | 0.001540 | 0.001580 | 0.001650 | 0.001810 | 0.001740 | 0.001660 | 0.001840 | 0.001850 | 0.001930 |
Technical specification limit | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
Indicator value | 0.1 | 0.1 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 |
Reactor Coolant System Activity | 10/07 | 11/07 | 12/07 | 1/08 | 2/08 | 3/08 | 4/08 | 5/08 | 6/08 | 7/08 | 8/08 | 9/08 |
Maximum activity | 0.002050 | 0.002020 | 0.002040 | 0.002140 | 0.002070 | 0.002220 | 0.000449 | 0.000501 | 0.000717 | 0.000595 | 0.000579 | 0.000614 |
Technical specification limit | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
Indicator value | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 |
Licensee Comments: none
Reactor Coolant System Leakage | 10/06 | 11/06 | 12/06 | 1/07 | 2/07 | 3/07 | 4/07 | 5/07 | 6/07 | 7/07 | 8/07 | 9/07 |
Maximum leakage | 0.011 | 0.020 | 0.010 | 0.070 | 0.020 | 0 | 0.030 | 0.020 | 0.030 | 0.610 | 0.010 | 0.010 |
Technical specification limit | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 |
Indicator value | 0.1 | 0.2 | 0.1 | 0.7 | 0.2 | 0 | 0.3 | 0.2 | 0.3 | 6.1 | 0.1 | 0.1 |
Reactor Coolant System Leakage | 10/07 | 11/07 | 12/07 | 1/08 | 2/08 | 3/08 | 4/08 | 5/08 | 6/08 | 7/08 | 8/08 | 9/08 |
Maximum leakage | 0.010 | 0.010 | 0.010 | 0.040 | 0.050 | 0.070 | 0.010 | 0.620 | 0.030 | 0.020 | 0.020 | 0.030 |
Technical specification limit | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 |
Indicator value | 0.1 | 0.1 | 0.1 | 0.4 | 0.5 | 0.7 | 0.1 | 6.2 | 0.3 | 0.2 | 0.2 | 0.3 |
Licensee Comments: none
Drill/Exercise Performance | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Successful opportunities | 11.0 | 19.0 | 57.0 | 72.0 | 66.0 | 28.0 | 50.0 | 90.0 |
Total opportunities | 14.0 | 20.0 | 58.0 | 75.0 | 71.0 | 28.0 | 54.0 | 92.0 |
Indicator value | 95.6% | 96.2% | 97.1% | 96.6% | 96.3% | 96.5% | 95.7% | 95.4% |
Licensee Comments: none
ERO Drill Participation | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Participating Key personnel | 104.0 | 106.0 | 114.0 | 113.0 | 111.0 | 114.0 | 99.0 | 94.0 |
Total Key personnel | 108.0 | 108.0 | 117.0 | 116.0 | 111.0 | 114.0 | 99.0 | 94.0 |
Indicator value | 96.3% | 98.1% | 97.4% | 97.4% | 100.0% | 100.0% | 100.0% | 100.0% |
Licensee Comments: none
Alert & Notification System | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
Successful siren-tests | 885 | 728 | 965 | 536 | 618 | 786 | 627 | 486 |
Total sirens-tests | 888 | 732 | 974 | 540 | 625 | 793 | 637 | 488 |
Indicator value | 98.9% | 99.4% | 99.4% | 99.4% | 99.2% | 99.1% | 98.9% | 99.0% |
Licensee Comments: none
Occupational Exposure Control Effectiveness | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
High radiation area occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Very high radiation area occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Unintended exposure occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 1 | 1 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none
RETS/ODCM Radiological Effluent | 4Q/06 | 1Q/07 | 2Q/07 | 3Q/07 | 4Q/07 | 1Q/08 | 2Q/08 | 3Q/08 |
RETS/ODCM occurrences | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Indicator value | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Licensee Comments: none