![]() |
Search Options | |||
Index | Site Map | FAQ | Facility Info | Reading Rm | New | Help | Glossary | Contact Us | ![]() |
ACCESSION #: 9606140133 Information & Support Services P.O. Box 3707 Seattle WA 98124-2207 June 5, 1996 G-1151-SJA-96-321 Document Control Desk United States Nuclear Regulatory Commission Washington, D.C. 20555 BOEING Reference: a) Boeing Letter G-1151-RSO-92-365 dated August 31, 1992; R. S. Orr to the NRC Operations Center b) NRC Letter Docket No. 99901227 dated August 12, 1992; L. J. Norrholm to R. S. Orr; Subject: Response to 10 CFR 21 Inquiry Dear Sir or Madam: In accordance with the reference correspondence and 10 CFR 21, Boeing is sending the NRC the attached error notice(s) received from our former software suppliers. Because of unknown current addresses, the following former customers were not notified: Reactor Controls, Inc. Echo Energy Consultants, Inc. Nuclear Applications and Systems Analysis Company (Japan) Nuclear Power Services Tenera Engineering Services Gibbs & Hill, Inc. Error notices have been sent to our other former customers. Very truly yours, Sandra J. Andrews Nuclear Administrator G-1151 M/S 7A-33 (206) 865-6248 Attachment(s): GTSTRUDL Program Report Form No. 96.17 Georgia Tech Computer Aided Structural Engineering Center Georgia Institute of Technology School of Civil & Environmental Engineering Atlanta, Georgia 30332-0355 USA 404-894-2260 404-894-8014 FAX May 30, 1996 Attention: Nuclear Administrator Boeing Information & Support Services P. O. Box 24346, M/S 7A-33 Seattle. Washington 98124-0346 RE: GT STRUDL Dear Sir or Madam: Enclosed please find copies of GTSTRUDL PROGRAM REPORT FORM No. 96.17 and a VENDOR ACKNOWLEDGEMENT FORM. Please sign and return the VENDOR ACKNOWLEDGEMENT FORM to acknowledge receipt of the GTSTRUDL Program Report. Thank you for reviewing the Program Report and for returning the Acknowledgement Form. Best regards. CASE Center Catherine Lee Configuration Control Manager CL/tlk Enclosures An Equal Foundation and Employment A Unit of the University Opportunity Institution System of Georgia GTSTRUDL Program Report Form GPRF No.: 96.17 DATE: May 29, 1996 FROM: Computer-Aided Structural Engineering Center Georgia Institute of Technology Atlanta, Georgia 30332-0355 SEVERITY LEVEL: X URGENT Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job. _ SERIOUS Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task. _ MINOR Problem can be worked around or problem poses high frustration factor. _ INFORMATIVE Documentation error, program usage tip, user inconveniences. Date Problem Confirmed May 29, 1996 Date Notification Sent May 31 1996 Computers All Operating System All Version All versions prior and including to 9601 Target Release for Correction 96.02 Senior Software Developer Signature Title R & D Division Hamid Zand Typed or Printed Name Date of Signature Signature Title Professional Services Division Typed or Printed Name Date of Signature Rev. 2.2 GTSTRUDL Program Report Form (Continued) GPRF No.: 96.17 DATE: May 29,1996 DESCRIPTION: STEEL DESIGN (Offshore Design Only, API codes) Offshore design codes, APIWSD20 and APIOCT84, will not check the bending stress provisions of a member when the internal axial force is less than 2.224 Newton (0.5 Pound). When the axial force is less than 2.224 Newton (0.5 Pound) and bending moment exists, only the shear stress is checked. Workaround: Apply an axial load which create an internal axial force greater that 2.224 Newton (0.5 Pound). Applicable GTSTRUDL User's Manual: For APIOCT84 code. Volume 8 Section 3.3. Table 3.3-2 Section 3.4 Prior to and including Revision N Prior to and including version 9601 For APIWSD20 code. Volume 8 Section 3.3, Table APIWSD20 Section 3.4 Revision P Version 9601 Rev 2.2 *** END OF DOCUMENT ***