![]() ![]() |
![]() |
![]() ![]() ![]() |
![]() |
![]() |
![]() |
![]() |
Fatality Assessment and Control Evaluation (FACE) Program |
![]() |
Hispanic Construction Laborer Dies and Two Coworkers Are Injured After Falling 10 Feet From an Unsecured Box on the Forks of a Forklift - North Carolina | ![]() |
| ||||||||||
SummaryOn August 26, 2002, a 23-year-old Hispanic construction laborer (the victim) died and two coworkers were injured after falling 10 feet to the ground from an unsecured wooden box that had been elevated on the forks of a rough terrain forklift (Photo 1). After the victim and his coworkers had been lifted in the box (Photo 2) to a position where they could wash a recently bricked wall, the forklift operator, who was also the victim's foreman, exited the forklift. Several minutes later the forklift operator and a coworker heard workers screaming and heard a scraping sound as the box and workers struck the ground. The forklift operator ran to help the workers who had fallen while the coworker called 911. The forklift operator performed cardiopulmonary resuscitation (CPR) on the victim who had no pulse and was not breathing. Emergency Medical Services (EMS) and police personnel responded within 5 minutes. EMS personnel continued CPR on the victim and provided first aid to the injured workers before transporting all three workers to the local hospital. The victim was pronounced dead in the hospital emergency room. One injured coworker was hospitalized and the other was treated for his injuries and released the following day. NIOSH investigators concluded that, to help prevent similar occurrences, employers should
Additionally,
Back to TopIntroductionOn August 26, 2002, a 23-year-old Hispanic construction laborer (the victim) died and two coworkers were injured after falling 10 feet to the ground from inside an unsecured wooden box elevated on the forks of a rough terrain forklift. In September 2002, officials of the North Carolina Occupational Safety and Health Administration (NC OSHA) notified the National Institute for Occupational Safety and Health (NIOSH), Division of Safety Research (DSR), of the incident. On December 2, 2002, a DSR safety and occupational heath specialist conducted an investigation of the incident and reviewed incident circumstances with the NC OSHA compliance officer assigned to the case. Photographs of the incident site, the forklift, and the wooden box taken by NC OSHA shortly after the incident were reviewed. No site visit was conducted as the project had been completed and the forklift and wooden box had been removed. The company office manager, who was assigned safety management duties following the incident, was interviewed by telephone. The medical examiner's and sheriff's reports were reviewed. The official cause of death was obtained from the medical examiner's report. The victim's employer was a roofing, framing, and masonry subcontractor that had been in business for 17 years. The company employed 49 full-time employees. Two masonry crews had been working at the incident site for 2 months placing and washing brick on the exterior walls of five recently completed buildings. The work shift started at 6:30 a.m. and ended at approximately 4:30 p.m. daily. The victim had moved from Mexico to the United States and had been working for the company as a laborer for 2 months before the incident. The victim's primary language was Spanish. One of the injured coworker's primary language was Spanish. The other injured coworker's primary language was English. The foreman who lifted the workers with the forklift spoke both English and Spanish. The company had no written comprehensive safety program. On-the-job training was provided on an as-needed basis by foremen and focused on training workers to complete job tasks. The company office manager reported that the forklift operator involved in the incident had indicated past forklift operator training at the time he was hired, but this training was not documented or evaluated by the company. The victim had no training beyond on-the-job task training. This was the company's first workplace fatality. Back to TopInvestigationThe site of the incident was an apartment complex where five two-story townhouses had been recently constructed. According to the office manager, the company had been subcontracted to perform masonry work on the apartments and had been working at the site for 2 months before the incident. They planned to complete the job in another month. The two crews assigned to the site were composed of two foremen, six masons and seven laborers. They arrived on site at approximately 6:30 a.m. on the day of the incident to perform brick work. It began raining and the two foremen decided to call off work for the day but, before doing so, decided to have workers wash bricks on a recently bricked exterior wall of an apartment building. One foreman asked the other foreman to get a forklift that belonged to the general contractor and pick up a box and drive the forklift and box over to the area near the apartment that was to be washed. The ground in the area where the forklift was to travel and the area where it was to be used was fairly level. Workers were to be elevated to a position next to the recently bricked apartment wall where they were to clean the bricks by using hand brushes dipped into pails of muriatic acid and then spraying the bricks with water. After the foreman drove the forklift over to his area, the foreman who had requested the forklift got on the forklift and lifted the unsecured wooden box with three men inside approximately 10 to 12 feet in the air to a location where they could wash and spray rinse the brick. Each worker was equipped with a pail of muriatic acid and a hand brush. A length of hose was coiled in the bottom of the wooden box and was connected to a water source below. Workers were to use the hose to spray the wall after washing it with muriatic acid. After he had elevated the workers, the foreman exited the forklift with its engine running and walked away to perform another task. There is no information available to determine whether the forklift's parking brake had been set before the foreman exited. Minutes later, the foreman who had elevated the workers heard workers' screams and a scraping sound as the box fell. Both foremen had been completing other tasks at the time and had their backs to the forklift and had not seen the box and workers fall. The incident occurred approximately 2 minutes after the lift at approximately 7:30 a.m. The foreman who had elevated the workers ran to help the injured workers while the other foreman called 911. One worker was lying away from the box and two were lying under the box. One edge of the box was lying on the victim's leg and a coworker was lying on top of the victim. The forklift operator performed cardiopulmonary resuscitation (CPR) on the victim, who had no pulse and was not breathing. Emergency Medical Services (EMS) and police personnel responded within 5 minutes. EMS personnel continued CPR on the victim and provided first aid to the injured workers before transporting all three workers to the local hospital. The victim was pronounced dead in the hospital emergency room. One injured coworker was hospitalized and the other was treated for his injuries and released the following day. Sheriff's office personnel interviewed the injured workers the day following the incident. The worker who had fallen clear of the box reported that he and two Mexican workers were washing some brick when all of a sudden the box flipped and threw him to the ground. The other worker, speaking through an interpreter, reported that he and the victim and a white male were washing some bricks on an apartment wall when all of a sudden the box flipped toward the left. He stated that he was standing on the right, the victim on the left, and the white male was in the middle. He stated that he fell on top of the victim. The forklift used in the incident had been rented by the general contractor from an equipment rental company and, according to the sheriff's report, the forklift operator had seen the forklift with the wooden box used by other subcontractors to lift personnel and therefore thought it was safe to use. According to the company office manager, the subcontractor owned two forklifts with safety platforms attached, but one of these was in a repair shop and the other was being used at another worksite. According to the NC OSHA report, the wooden box measured 4 feet deep by 4 feet wide by 10 feet long; the forklift was fully functional; and the forks on the forklift were spaced 36 inches apart. The forks on the forklift had the capacity to expand to 66 inches apart. When sheriff's personnel examined the underside of the box, they found no support to prevent the box from tilting on the forks of the forklift. The box had three sides and a floor and had sustained damage on the top left section where it had struck the ground. The rental company inspected the high-reach telescoping rough terrain forklift that had been used during the incident and determined that it was functioning correctly. The lift capacity of the equipment was 5,000 pounds. According to the rental representative, the rental company does not rent a safety platform/lift carriage for this type of equipment because the equipment is designed for material handling only. Back to TopCause of DeathThe medical examiner's report indicated that the cause of death was blunt-force injuries and chest compression. Recommendations/DiscussionRecommendation 1: Employers should implement a policy which requires the use of a safety platform secured to the lifting carriage and/or forks when lifting personnel with a powered industrial truck (e.g., forklift).Discussion: In this incident, a wooden job-made trash box used as a work surface was elevated, unsecured, on the forks of a rough terrain forklift. According to OSHA, when using trucks equipped with vertical only, or vertical and horizontal controls elevatable with the lifting carriage or forks for lifting personnel, the use of a safety platform secured to the lifting carriage and /or forks is required for the protection of personnel being lifted.1 A safety platform, which is referred to as a lifting cage, should be equipped with a proper guardrail system and a means for locking the gate. The lift cage must be safely secured to the mast of the lift truck. Forks on the lift truck must be opened as wide as possible. The person operating the lift truck must not leave the lift truck; this ensures that the person in the lift cage can give immediate instructions to the operator. A means should be provided to allow personnel on the platform to shut off power to the forklift.2 To further improve safety while working from an elevated safety platform, an independent restraining system should be used such as a full-body harness with an attached lanyard or deceleration device properly secured to a safe anchorage point on the mast of the forklift. This type of restraint should be used to prevent workers from falling should the safety platform fall from the forks. Employers can obtain additional information regarding forklift safety in NIOSH Alert 2001-109.3 Additionally, employers should consider going beyond minimum OSHA requirements and choose a safer method for positioning workers in elevated work areas. An aerial platform or a scaffold appropriate for the job and used correctly may provide a safer alternative for positioning workers to conduct brick washing work. The Equipment Manufacturers Institute, a proprietary organization which produces many safety manuals for operators and mechanics, recommends in the Rough Terrain Forklift Safety Manual "that a rough terrain forklift is designed to lift and transport material and should not be used to elevate personnel. Only equipment designed specifically to elevate personnel should be used for this purpose."4
| ||||||||||||
![]() |
||||||||||||
![]() |
||||||||||||