Aerosol Science Experimental Facilities
The aerosol science lab has an array of experimental capabilities and personnel expertise to perform basic and applied aerosol research. Test facilities include several large aerosol test chambers and aerosol wind tunnels to produce a wide range of very controlled aerosol environments. The facilities and labs are supplied with sophisticated aerosol characterizing equipment and instrumentation, data logging capabilities, chemical and biological hoods, and sample preparation areas. These facilities are applied to a spectrum of aerosol science from basic aerosol experimentation to performance characterization of prototype and commercial aerosol collection/detection systems.
Features/Capabilities:
Aerosol Chamber : Chamber Volume - 70 M 3
- Temperature/humidity control (–28F to 120F, 25% to 90% rh)
- Mixing fans and wash down system
- Recirculation filters to tailor aerosol concentration levels
- HEPA-filtered exhaust
Specialized aerosol generators: Ink Jet Aerosol Generator (IJAG) for precisely controlled sizes and quantities especially useful for testing limit of detection.
- Pocket-portable “Puffers” based on metered dose inhaler technology
- Vibrating Orifice generators
- Spinning Disk generators*Sonic nozzles
- Nebulizers
Open Jet Aerosol Wind Tunnel: Flow Velocity: 1.5-12 M/S
- 1.0 M diameter x 1.2 M long jet stream enclosed in 2.4 x 2.4 x 2.4 M test section
Low Velocity Open-Jet Bio-Aerosol Wind Tunnel:
Flow Velocity: 0.6-6 M/S
- 0.5 M diameter x 0.8 M long jet stream enclosed in 1.2 x 1.0 x 1.8 M test section
- HEPA-filtered inlet and exhaust
High Velocity Aerosol Wind Tunnel: Flow Velocity: 4.5-27 M/S in 0.7 x 1.0 M test section, configurable to 62 M/S for UAV sampler testing
LIDAR Test Cell “Stealth Tube”: Field portable horizontal test chamber for Stand-off detector testing
- Dimensions: 1.1 M Dia x 9.1 M Length (Volume: 9M 3)
- Self-contained aerosol generators with mixing fans
- Wash down capable stainless steel construction
- UV and visible light transmitting windows at both ends of tube
- Recirculation filters to tailor aerosol concentration levels
- HEPA-filtered
Aerosol Breeze Tunnel: Smoke and Obscuration study breeze tunnel adapted for bio-aerosol studies
- 196 feet long, 14 feet wide and 14 feet high
- 5 mph fixed wind velocity
- 14’ x 14’ vehicle-accessible entrance