NIOSH Publication No. 2007-153


Technology News 527 - The Partial Cab: A New Noise Engineering Control for Surface Drill Rigs

August 2007

Publication first page
Document cover page
Click the image to enlarge

NIOSH, in partnership with stakeholders in the mining and surface drilling industries, conducted research to develop engineering control technologies that reduce workplace noise exposure. The result of this research partnership is the development of a partial cab. Background: Noise-induced hearing loss (NIHL) continues to be an occupational health problem in the U.S. mining industry. Hearing loss data suggest that by age 50, nearly 90% of coal miners have a hearing impairment. This compares to 10% for a general population of nonexposed males. Previous studies showed that operators of noncab surface drill rigs are overexposed to noise. These rigs are used in various surface drilling industries, including mining and construction. Many surface rigs do not have full cabs as a result of the original equipment manufacturer design or the prohibitive cost of aftermarket products.

Author(s):Reinke-DC
Reference:Pittsburgh, PA: U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, DHHS (NIOSH) Publication No. 2007-153, Technology News 527, 2007 Aug; :1-2

   2007-153 (PDF, 1411 KB)


A link above requires the Adobe Acrobat® Reader.
You can download a reader for free from Adobe through our Accessibility/Tools page.
Get Adobe Reader
Page last updated: November 13, 2008