NIOSHTIC-2 No. 20031470


Sound Power Level Study of a Roof Bolter

2006

Publication first page
Document cover page
Click the image to enlarge

The National Institute for Occupational Safety and Health (NIOSH) has initiated a study of a roof bolter to reduce noise exposure to mine roof-bolter operators. An important segment of this research entails determining the affect of various drilling configurations on the performance (penetration rate) and sound power emissions when drilling into granite. Test conditions included using various combinations of rotational speeds and thrusts, using 2.54- and 3.49-mm- (1- and 1 3/8-in.-) diameter hexagonal and round drill steels, using vacuum and wet conditions and using drill media of differing compressive strengths. This paper details the affects of each of these variables on the performance and sound power level emission. When drilling into granite, it was found that wet drilling generated lower sound power levels and performed better than vacuum drilling.

Author(s):Peterson-JS, Kovalchik-PG, Matetic-RJ
Reference:Trans Soc Min Metal Explor 2006 320:171-177

   splso (PDF, 1717 KB)


A link above requires the Adobe Acrobat® Reader.
You can download a reader for free from Adobe through our Accessibility/Tools page.
Get Adobe Reader
Page last updated: September 17, 2008
Content Source: National Institute for Occupational Safety and Health (NIOSH) Mining Division