Fatality Assessment and Control Evaluation (FACE) Program |
|
Machine Operator Dies When Struck By Flying Wood Chipper Guard |
| |||||||||||
SummaryOn July 22, 2005, a 56-year-old machine operator (the victim) died after he was struck by a flying guard from a wood chipper. The victim was working alone when he shut down the chipper. The chipper was a machine used to reduce wood edging and other wood waste into wood chips. The victim shut down the chipper and the blade continued to rotate for up to thirty minutes. The victim was found by one of the sawmill partners at approximately 6:00 p.m. The partner notified Emergency Medical Services (EMS) at 6:11 p.m. They arrived at 6:17 p.m. The EMS took the victim to the hospital located 20 to 25 miles away, at 6:23 p.m. The local EMS requested a paramedic intercept with a larger, better trained and more experienced crew. The EMS arrived at the hospital at 6:46 p.m. A doctor in the hospital declared the victim dead at 6:57 p.m. The FACE investigator concluded that to help prevent similar occurrences, employers should:
IntroductionOn July 22, 2005, a 56-year-old machine operator (the victim) died after he was struck by a flying guard from a wood chipper. The FACE investigator learned about the incident from the death certificate. The FACE investigator reviewed official reports and sent a letter to the company requesting an interview. The FACE investigator followed up with a telephone call to the company and an on-site interview was arranged for July 27, 2006. The company where the incident occurred was a saw mill. The logs were purchased by another company. This company mainly cut the logs to dimensional size lumber (i.e. 2” by 4”) in the rough. The saw mill also manufactured other wood products such as landscape timbers, fence posts, and rough sawn 8 foot boards and wood chips. The wood products were then returned to the original company for pressure treating. The waste wood was transported by a conveyor to the chipper (Figure 1) with the waste made into wood chips. The chipper was a 48” machine manufactured by Morbarb Industries Inc. of Winn, Michigan. The chipper blade was guarded by a heavy steel guard that was hinged on one side and attached to the chipper ( Figure 2). The guard weighed approximately 200 pounds. The guard protected the rotating blade from accidental contact (Figure 3). The company consisted of twelve employees. Eleven of the employees worked in the saw mill using various saws and chippers. Some employees were trained in the use of industrial lift trucks. The employees received training in Lockout Tagout and the lift truck operators were licensed. While the company had a Lockout Tagout program, the program did not take into account the stored energy of the chipper. The chipper took up to 30 minutes to wind down once power was turned off.
Back to TopInvestigationOn the day of the incident, the victim was doing his normal work duties at the saw mill. The victim was one of the previous owners of the saw mill. He had started the business in the 1970s with a partner. They (the victim and the partner) sold the company in October 1996. The victim continued to work in the saw mill for the new owner. The victim worked a 7:00 a.m. to 3:30 p.m. shift. He usually worked after the normal shift ended to prepare the chipper for the blade change. The chipper blade was changed daily by installing a newly sharpened blade the night before beginning the next day’s shift. The victim was found by a partner at 6:00 p.m. The victim purchased the chipper used in the incident. The 48” chipper was manufactured by Morbarb Industries. The year that the machine was manufactured is unknown because the machine had no visible model or serial numbers. The chipper did not have an operator’s manual, safety manual, or maintenance manual. The wood process was as follows: The logs were off-loaded in the saw mill yard. The logs were then transported as needed to the saw mill for debarking. The debarked logs were then cut to size by a horizontal band saw and trimmer saws. The logs were transported to the saws by use of log carriages. The waste pieces of wood were transported by a conveyor to the chipper. The day of the incident, the victim opened the guard for the chipper blade while the chipper blade was still rotating. The guard flew off and was found 28 feet away from the chipper. The guard sat on top of the blade and was hinged to the lower guard protecting the blade. The guard hinge had been welded previously, but not adequately, and the weld had broken. The upper hood guard struck the still rotating blade, causing it to break off at the location where it was welded. The 200-pound upper hood guard was projected away from the chipper striking the victim in the forehead and resting 28 feet away from the chipper. The chipper blades showed a gouge in the blade where the guard had struck the blade. The victim was found about seven feet away from the chipper. There were no witnesses to the incident. The chipper was not running when the victim was found. The incident occurred 2 to 2 ½ hours after the shift ended. The Morbarb chipper had a caution sign located on the bottom which clearly stated “This machine must be locked out prior to servicing.” The chipper had a control box with an emergency stop on it, in addition to start and stop push buttons. The chipper disconnect was turned off, but not locked out. Locks and tags were available for used by the employees if needed. The chipper hood was opened on a daily basis, normally at the end of the work shift, to inspect and replace the chipper blades. The victim was familiar with electrical systems and maintenance in the saw mill. Management had cautioned the victim, about 36 months prior to the incident, about working on the chipper with the blade still rotating. Back to TopCause of DeathThe official cause of death was cerebral contusions and lacerations caused by blunt trauma due to being struck by a metal shroud. Recommendations/DiscussionRecommendation #1: Ensure that guards are properly repaired or replaced, as needed, before returning machines to service.Discussion: Guards are used to protect workers from moving parts and should be inspected to identify hazards. Replacement or repair of guards should be performed in such a way that they effectively guard against injury and ensure that the guard itself does not become a hazard.
| ||||||||||||
Wisconsin Case Reports | ||||||||||||