![]() |
![]() |
Fatality Assessment and Control Evaluation (FACE) Program |
![]() |
Youth Dies in Tractor Rollover Attempting to Pull Trailer Out of Mud | ![]() |
| ||||||||||
SummaryOn April 21, 2003, a 15 year-old youth died when he was pinned under the tractor he was driving. The deceased had driven the tractor into the field located behind and next to the back yard of his family home to retrieve a trailer to haul wood. The trailer became stuck in the mud. The victim connected a log chain to the trailer and tried to pull it out of the mud with the Ford tractor, Model 8 N. This model has widely-spaced front wheels. Figure 1 shows the tractor after it overturned backwards. Figure 2 shows the front of the tractor facing the trailer. The victim’s friend was driving past the property on the road and saw the tires of the tractor in the air. The friend turned around on the road and drove into the yard. He went to the house to see if his friend (the victim) was there, but no one answered as he called for him. He then ran out to the tractor in the field and found the victim pinned underneath the tractor. He drove to a neighbor’s home to get someone to call for help. He drove back to the victim’s home. In the meantime, the victim’s sister who had heard the friend’s truck but was unable to answer the door at the time, went out and saw the tractor upside down. She ran over and saw the victim under the tractor. She ran back into the house and called emergency medical services (EMS). Within fourteen minutes the emergency medical personnel had arrived from a nearby town and had removed the victim from under the tractor. He was taken to a local hospital where he was pronounced dead. The NIOSH FACE investigator concluded that, to help prevent similar occurrences, farmers and employers should:
Additionally:
IntroductionOn April 21, 2003, a 15 year-old youth died when he was pinned under the tractor he was driving. On April 23, 2003, Wisconsin FACE investigators were informed of this incident via a newspaper clipping. The death certificate, the sheriff’s report and the coroner’s report were reviewed and an investigation was initiated. On March 25, 2005, the FACE director/field investigator traveled to the home of the deceased and talked with the victim’s family. His mother and sister shared information about the victim and the incident. The family grew up and lived in the area all of their lives. The family owned their home adjacent to their neighbor’s field where the incident occurred. The victim’s father worked loading trucks in a gravel quarry and the victim’s mother worked at home. The deceased was a high school student. The Ford tractor had been in the family for many years. Approximately 5 years before the incident, the tractor was no longer needed on the home farm and was given to the victim’s family. The victim loved the tractor and at age 10 learned very quickly how to drive it. He often drove the tractor in the field behind their home. The field was flat with no trees, hills or slopes and the family could see him easily from their home. The victim learned about machinery and safety from his parents. While he took the hunter safety training course when he was eligible, he did not participate in the tractor safety course. The family used the tractor to haul wood, plow the garden and plow snow. The victim was described as very adept at fixing and creating things, hunting, and fishing. The tractor was described as his pride and joy. The victim and his father both loved machinery and spent time together converting an old truck into a trailer. Back to TopInvestigationOn the day of the incident, the victim had a vacation day from school and slept until his mother awoke him later than usual. That evening the parents were going to the high school to enroll the victim in driver’s education that would be taught in the summer. Before they left, they asked the victim to haul wood and put it into the basement before dark. They did not know he would use the trailer. They expected him to use the manure spreader from the garage located near the house. The victim spent time with his friend who left him at approximately 6:00 and 6:30 p.m. He watched television with his sister until approximately 7:20 p.m. The victim then went outside. Since the event was not witnessed, the circumstances leading to the victim being pinned under the tractor are postulated based on the review of the incident and the interviews with the family. The victim drove the tractor to the field to retrieve the flat bed trailer that had been converted from an old truck. The trailer got stuck in the mud. The victim found a logging chain and connected the hitch of the trailer to the back of the tractor with the chain. The victim was attempting to pull the trailer out of the mud with the tractor when the tractor flipped over backwards and pinned him underneath. The tractor flipped backwards with the front end of it upside down facing west. The trailer was about 15 feet further west of the tractor. Figure 2 shows the tractor and the trailer. About 8:00 p.m. the friend who had left the victim earlier, was driving on the road past the victim’s house and field. He saw the tractor tipped over with the wheels up in the air. The friend turned around and went to the house to see if his friend (the victim) was there, but no one answered when he called out for him. He then ran out to the tractor in the field and found the victim pinned underneath the tractor. He drove to a neighbor’s home and knocked on the window to get help. In the meantime, the victim’s sister who had heard the friend’s truck, but was unable to answer the door at the time, went out and saw the tractor upside down. She ran over and saw the victim under the tractor. She ran back into the house and called emergency medical services (EMS). The friend went back to the victim’s house and stayed with the victim’s sister for a few minutes before leaving to see if the rescuers were coming. Within fourteen minutes EMS responded and removed the victim from under the tractor. EMS personnel transported the victim to a local hospital. The parents were located and were present when the victim was pronounced dead at the hospital at 9:06 p.m. The tractor had a 3-point hitch. It is unknown if the tractor had water for weight in the tires. The tractor was a Ford and the research indicates this was a model 8N. This model was tested at the University of Nebraska between 1947 and 1950. The tractor tested at that time to have a 20-30 horsepower engine and weighed 2717 pounds. It could pull a maximum of 2810 pounds. This model did not have a ROPS and was manufactured before the time that a tractor could be retrofitted with ROPS. The flat bed trailer had large dual wheels on each side and a hitch. It also had a jack so it could be raised in order to hook it up to the tractor. In this instance, the trailer was not hitched directly to the tractor. A log chain was used to connect the two pieces of equipment. The field had a flat terrain and was wet and muddy at the time of the incident. While April 21 was 52 degrees and clear, the Wisconsin State Climatology office shows that between April 16 and the morning of April 21, a total of 4 inches of snow fell in this geographical area. Rescuers sunk about 3 inches into the ground when walking in the area where the incident occurred. Back to TopCause of DeathThe cause of death as stated on the death certificate was open skull fracture with severe brain injury. Recommendations/DiscussionRecommendation #1: Provide tractors equipped with rollover protective structures (ROPS) and seat belts.Discussion: The tractor involved in this incident was manufactured in the late 1940’s to the early 1950’s before ROPS were required and too early a model to be able to retrofit it with ROPS. These safety features were not required until 1976 when OSHA standard 1928.51 went into effect. Though the standard did not require the retrofitting of all tractors manufactured before 1976, ROPS on tractors would greatly enhance the safety of the operator. The tractor involved in this incident was not equipped with a ROPS. For a ROPS system to be effective, a seat belt must be used at all times. If a seat belt is not worn, the operator could be crushed not only by the tractor, but by the ROPS as well if the tractor overturned.
|
![]() |
Figure 3. Prevent Upsets – Tow
only from the Drawbar or Three-Point-Hitch Drawbar attachment. Set
at Recommended Drawbar Height. (Deere & Co., p. 180) |
Discussion: According to the National Children’s Center for Rural and Agricultural Health and Safety, children under age sixteen should not be completing tasks that are rated as a task with “increased hazard and complexity.” Hitching the tractor to move stuck or immovable objects is one of the tasks listed that requires an adult to complete.
Discussion: Employers of youth may be subject to laws of state and federal authorities and must know and meet the provisions of all pertinent requirements. The Fair Labor Standards Act provides standards for employment of youth in certain enterprises. However, the Child Labor Provisions specifically exempt children who work on their family’s farm from the protection of the Act. The state where the incident occurred also exempts family farms from child labor requirements.
Note: In this case, the youth was planning to haul wood.
Additionally:
Discussion:
Staff members of the FACE Project of the Wisconsin Division of Public Health, Bureau of Occupational Health, conduct FACE investigations when a machine-related, youth worker, Hispanic worker, highway work-zone death, farmers with disabilities or cultural and faith-based communities work-related fatality is reported. The goal of these investigations is to prevent fatal work injuries studying: the working environment, the worker, the task the worker was performing, the tools the worker was using, the energy exchange resulting in fatal injury and the role of management in controlling how these factors interact.
To contact Wisconsin State FACE program personnel regarding State-based FACE reports, please use information listed on the Contact Sheet on the NIOSH FACE web site. Please contact In-house FACE program personnel regarding In-house FACE reports and to gain assistance when State-FACE program personnel cannot be reached.