Skip Navigation
National Institute of Environmental Health SciencesNational Institutes of Health
Increase text size Decrease text size Print this page

Specific Study

Word (http://tools.niehs.nih.gov/portfolio/sc/detail_doc.cfm?appl_id=7612102&ext=.doc)  Download Microsoft Word Viewer | Excel (http://tools.niehs.nih.gov/portfolio/sc/detail_xls.cfm?appl_id=7612102&ext=.xls)  Download Microsoft Excel Viewer | PDF (http://tools.niehs.nih.gov/portfolio/sc/detail_doc.cfm?appl_id=7612102&pdf=1&ext=.pdf)  Download Adobe Reader

Microchip-Based Perchlorate Analyzer for Water Remediation Monitoring and Field A

Principal Investigator
Willard, Dale
Institute Receiving Award
Advanced Microlabs, Llc
Location
Fort Collins, CO
Grant Number
R43ES017200
Funding Organization
National Institute of Environmental Health Sciences
Award Funding Period
25 Sep 2008 to 24 Sep 2009
DESCRIPTION (provided by applicant): This Small Business Technology Transfer Phase I project will develop a prototype online perchlorate monitor for a resin bed perchlorate remediation reactor. The device will be have less than 4 ppb limit- of-detection, provide results in less than 3 min., and require only periodic microchip replacement as routine maintenance. Currently, perchlorate can only be detected below 10 ppb using laboratory based equipment requiring trained technicians and, most importantly, at least several hours of time, and therefore, impractical for online monitoring. The Henry Group at Colorado State University has recently demonstrated sub ppb perchlorate detection using a patent-pending lab-on-a-chip technology with results that include real water sample testing. This technology opens the door for online monitoring of perchlorate remediation operations, which will significantly reduce the costs. Entire resin beds costing $100k in materials and additional costs in disposal would no longer be needed. This Phase I proposal will: 1. Develop pumps, valves, instrumentation, etc. to assemble a field deployable device, 2. Optimize our microchip functions by incorporating a sample membrane barrier and assessing nonhazardous alternative internal standards, and 3. Method validation and field testing. PUBLIC HEALTH RELEVANCE: Human exposure to perchlorate is of concern because of the potential for impaired thyroid function, leading to a number of developmental delays and other medical problems. Its prevalence in the environment only gained interest in the late 1990's, once a method was developed for its detection at the 4 ppb level. In 2005 after being added to the Environmental Protection Agency's (EPA) Unregulated Contaminant Monitoring Rule (UCMR1) list, a sampling of 2800 large water systems and 800 smaller systems, representing less than 10% of all US water systems, revealed contamination in 153 sites over 25 states. As of 2005, 120 remediation projects were underway, including 15 superfund sites, costing hundred's of millions of dollars to fund, mostly coming from government coffers. Our online monitoring device will significantly reduce costs for remediation. In addition to lowering costs to existing remediation, it will also allow smaller communities address cleanup that would otherwise not have enough resources.
Crisp Terms/Key Words:
Science Code(s)/Area of Science(s)
Primary: 80 - SBIR/STTR
Secondary: 25 - Superfund Basic Research
Program Administrator
Beth Anderson (tainer@niehs.nih.gov)
USA.gov Department of Health & Human Services National Institutes of Health
This page URL: http://tools.niehs.nih.gov/portfolio/sc/detail.cfm
NIEHS website: http://www.niehs.nih.gov/
Email the Web Manager at webmanager@niehs.nih.gov
Last Reviewed: 21 August 2007