Investigation: # 02-MI-60-01
Millwright Dies from Fall Off Ladder
SUMMARY
![]() |
Figure 1 |
RECOMMENDATIONS
INTRODUCTION
On Wednesday, June 12, 2002, a 54-year old millwright was killed when he fell from a ladder. He was installing new copper lines on a 22-foot plant ceiling. On June 13, 2002, MIFACE investigators were informed by the Michigan Occupational Safety and Health Act (MIOSHA) personnel who had received a report on their 24 hour-a-day hotline that a work-related fatal injury had occurred on June 12, 2002. On July 11, 2002, the MIFACE researcher interviewed the Vice-President of the plant who was also the Technical Director. He accompanied the researcher into the plant, showed her the incident site and described the events on the day of the fatality. During the course of writing the report, the autopsy results and the MIOSHA citations were obtained.
The MIOSHA investigation resulted in three citations being issued to the company: one citation for failing to provide a training program for employees using extension ladders; one for the ladder being unsecured; and one for failing to develop and present an accident prevention program.
INVESTIGATION
On Wednesday, June 12, 2002, a 54-year old millwright was installing new copper lines near a 22-foot plant ceiling for a company that manufactured lubricants and release agents for the die cast industry. The company had been in business for 44 years and employed nine people. The victim had been a millwright for over 30 years. He was working as a temporary employee at the time of the incident. He had done temporary jobs for the company in the past and had recently worked for another company in the neighborhood doing the same type of work.
![]() |
Figure 2 |
No one saw how the victim had set up his equipment or saw him working on the lines. No obvious reason was apparent for him to have fallen from the ladder. No markings were apparent on the I-beam, hoist crossbeam, or floor to indicate what might have occurred. The container of material he had been using to connect the pipes was placed on the building I-beam (Figures 1 and 2). Neither his height nor his reach was known, so how far he would have had to reach to work on the pipes he was installing was not known.
The extension ladder belonged to the victim and appeared to be in good condition (Figure 3). It was a fiberglass extension ladder with aluminum rungs. The area around his ladder was clear at the time he was working there.
The worker who investigated the noise found the victim on his right side perpendicular to the ladder with his back toward the ladder. He was lying with his head toward the rear of the plant and his feet toward the area where he was working. It appears unlikely that he moved after his fall, because the worker who investigated the noise was quite close to the area where he fell.
The height of the ceiling was 22 feet. The lines he was installing were located at approximately 18 feet. When he was found, his extension ladder was standing upright, leaning against a hoist crossbeam behind the area where he was working, not on the building I-beam where he had placed his material.
It was not possible to take measurements, so the distance between the crossbeam and the I-beam is unknown. The angle at which the ladder was found leaning against the crossbeam was not available. When the ladder was pulled backwards, it contacted the back of the building I-beam, so it appeared that it had been purposely balanced on the hoist crossbeam and had not fallen from the building I-beam onto the crossbeam. For the ladder to have fallen from the I-beam onto the hoist crossbeam, it would have had to move forward into the incline angle.
![]() |
Figure 3 |
Based on the position of the ladder and the position in which the victim was found, it is possible he was standing on the ladder with his back to it. As he fell he twisted to the right and fell onto his right side. The emergency medical personnel indicated that it appeared that he had fallen heavily onto his right side, because he had multiple rib fractures on the right side as well as head injuries on the right.
CAUSE OF DEATH
The cause of death as stated on the death certificate was multiple injuries, multiple blunt injuries to the head and trunk consistent with a fall.
RECOMMENDATIONS/DISCUSSION
Employers should develop a written accident prevention plan that identifies and describes hazards that could be encountered in the worksite and how to recognize and avoid them.
Although the workplace was an industrial site, the installation of the copper piping was construction work. The victim had done work at the site previously, but was not a full-time employee. The lubricants and die release products the company manufactures had been absorbed into the floor over the years. Instruction regarding this fact would have reminded the victim of the nature of the flooring and his footing. The soles of his shoes may have become slippery by having picked up the lubricants or die release products on the floor. The rungs of the ladder would also then have become slippery and could have caused him to lose his footing.
Ensure workers are trained in the safe use of ladders and follow safe procedures.
Reinforcement of safe ladder practices by means of an accident prevention plan and training would have addressed the following items.
REFERENCES
MIFACE (Michigan Fatality and Control Evaluation), Michigan State University (MSU) Occupational & Environmental Medicine, 117 West Fee Hall, East Lansing, Michigan 48824-1315. This information is for educational purposes only. This MIFACE report becomes public property upon publication and may be printed verbatim with credit to MSU. The author of this report is working under contract to MSU and is affiliated with Wayne State University. Reprinting cannot be used to endorse or advertise a commercial product or company. All rights reserved. MSU is an affirmative-action, equal opportunity employer.
To contact Michigan State FACE program personnel regarding State-based FACE reports, please use information listed on the Contact Sheet on the NIOSH FACE web site Please contact In-house FACE program personnel regarding In-house FACE reports and to gain assistance when State-FACE program personnel cannot be reached.