![]() |
|
![]() |
Fatality Assessment and Control Evaluation (FACE) Program |
![]() |
Tow Truck Operator Pinned Under Sport Utility Vehicle When Working Under It |
![]() |
|
||||||||||
SummaryOn March 18, 2005, a 34-year-old male tow truck driver was killed when the sport utility vehicle (SUV) he was preparing to tow fell on top of him. This was his third run of the day. The SUV had sustained front-end damage when it left the roadway and struck a tree in a residential yard. Both the front tires were flat and the passenger's front tire had separated from the rim. The decedent arrived and pulled the SUV onto the roadway with his tow truck. He repositioned the tow truck to the front of the vehicle. The decedent lowered the truck boom and attached the chains. It is unknown how the decedent placed the chains under the SUV. He did not utilize wood blocks to chock the SUV's rear tires or secondary jack to support the SUV, both of which were available on the wrecker. He told police that he was going to perform a wheel lift, although based on the description of the lift in the police report he performed a sling lift. It does not appear he used the wheel lift arm to lift the disabled vehicle or to provide a backup means of support for the raised vehicle. The wheel lift arm was at ground level when the incident occurred. After attaching the chains and raising the vehicle, the decedent positioned himself on his back, approximately mid-chest under the SUV, apparently to either free the transmission or the transfer case so that the rear wheels would rotate when in tow. When he popped the transmission, the vehicle lurched and fell, landing on the decedent across his neck and chest. 9-1-1 was called. Emergency responders declared the decedent dead at the scene.
Recommendations:
IntroductionOn March 18, 2005, a 34-year-old male tow truck driver was killed when he was crushed under a SUV that he was preparing to tow. On March 18, 2005, MIFACE investigators were informed by the Michigan Occupational Safety and Health Administration (MIOSHA) personnel who had received a report on their 24-hour-a-day hotline that a work-related fatal injury had occurred on March 18, 2005. On June 2, 2005, MIFACE interviewed the co-owner of the tow truck company. During the course of writing the report, the police report and pictures, medical examiner's report and MIOSHA file and citations were reviewed. Although not used in this report, the company co-owner permitted MIFACE to take pictures of the vehicle that was used by the decedent during the tow truck incident. The pictures used in this report are courtesy of the responding police department. MIFACE altered the pictures to preserve the employer's anonymity and the decedent's position next to the SUV. The employer provided roadside service and vehicle recovery and towing. The company was a designated AAA responder, and had been in business for about seven years. The company also operated a salvage yard on its premises. The company employed 20 individuals, of which 15 had the same job title as the decedent, tow truck driver. The decedent had been employed full time with this company for seven years. Tow truck drivers worked eight-hour shifts. Company drivers were paid by how many calls they turned in a shift. They were not paid hourly. The company had an employee handbook, but there were no written safety procedures or rules in place for the specific task being performed by the decedent. The company owner had primary responsibility for safety. His knowledge of safety was based on on-the-job experience. The company did not have a Health & Safety Committee on site and they did not have a written disciplinary policy for health and safety violations. The company relied upon the AAA Vehicle Towing Guidelines to provide guidance for towing different types of vehicles. On-the-job health and safety training was provided by the employer. Employee attendance at training sessions was recorded and maintained. The owner stated that all employees came together on a monthly basis and talked about the unique things that had happened to them in the field, including health and safety issues they encountered. MIOSHA General Industry Safety and Health Division personnel issued the two Serious and two Other-than Serious citations to the employer at the conclusion of their investigation. SERIOUS:
OTHER-THAN-SERIOUS:
Back to TopInvestigationThe decedent's work shift began at 8:00 a.m. Although the tow truck was not "officially" assigned to the decedent, he usually drove this tow truck. The tow truck was equipped with wood blocks and a secondary jack. It had been snowing that morning but was not raining or snowing at the time of the decedent's death. Ice was not present on the road surface. The straight two-lane, asphalt roadway had a slight incline with no shoulder or curb. A state police dispatcher notified the company for whom the decedent worked that a SUV had left the roadway, hit a tree in a yard sustaining significant front-end damage as well as deflated front tires, and that the vehicle needed to be recovered. Police cars were positioned behind the tow truck and the accident vehicle to stop traffic. The decedent arrived on-scene at approximately 9:20 a.m. It was his third run of the day. The decedent removed the vehicle from the yard/tree by winching it out from the rear onto the street. The SUV was in Park when in the yard at the tree. After the decedent winched the SUV onto the street, the decedent disengaged the tow truck from the rear of the vehicle and repositioned the back of the tow truck to the front of the damaged vehicle.
The company owner stated that the normal procedure would have been to winch the car out of the yard, position the vehicles and then chock the tires (front or rear depending upon the towing procedure). Apparently, the decedent decided to haul the damaged SUV to the repair destination by lifting the front end and using the rear tires to tow. The keys to the SUV were on the dash, although it is unknown whether the keys would have been effective in permitting the movement of the gearshift from Park to Neutral. There was a switch on the dash panel for the transfer case. According to the police report, the police officer asked the decedent if he was going to do a dolly lift on the vehicle. The decedent said no, he was going to do a wheel lift. It appears the decedent activated the boom and extended the boom so that he could use the slings and chains. As described in the police report, the decedent secured one chain to the front left of the vehicle and another chain to the front right of the vehicle. The ends of the chains were attached to stationary hooks on the boom of the truck. It is unknown if the decedent wrapped the chains in an appropriate manner on the SUV's undercarriage. The decedent did not use the wood blocks on the tow truck to chock the SUV's rear tires. The decedent then lifted the front of the vehicle. The decedent took a floor mat from the tow truck to lie on while he was under the SUV. He did not provide a means of secondary support, such as a jack stand, or set the wheel lift device under the vehicle after lifting the front of the vehicle before placing himself under the vehicle. Placing his waist and upper torso just behind the driver's side front axle, and using a screwdriver from his truck, it appears he attempted to release the transmission linkage. The decedent was presumably attempting to either free the transmission or the transfer case. As the decedent attempted to free the transmission or transfer case, the SUV lurched forward and fell onto him. Witnesses described hearing a “loud noise” and then the vehicle fell.
One of the responding police officers noticed that the chain attached to the driver's side of the accident vehicle gave way when the vehicle fell onto the decedent. Another police officer ran to the controls of the tow truck and raised the boom of the wrecker in an attempt to raise the vehicle; this was unsuccessful. The officer then extended the wheel lift device under the vehicle to attempt to raise the vehicle. Again, the SUV could not be lifted, because the front of the SUV was too low to the ground and there was not enough clearance to place the wheel lift between the body of the vehicle and the ground. In a third attempt to lift the vehicle, the officers tried to place a portable hydraulic jack from the patrol car under the driver's side of the vehicle to raise it, but the vehicle was too close to the ground to get a jack under it. Another police officer tried to raise the SUV by attaching a J-hook chain from the boom to the front driver's side. When the boom was raised, the vehicle began to slide back instead of raise up, so the lifting operation was stopped. Upon arrival of the local fire department, fire department personnel placed air bags under the vehicle and attempted to raise it. The vehicle was finally raised using spreaders. The decedent was pulled from underneath the vehicle and was declared dead at the scene. MIOSHA found that one of the chains on the tow truck had a knot in it. It is unknown whether the knot was a result of rescue attempts or was present prior to the incident. Back to TopCause of DeathAs stated by the Medical Examiner on the death certificate, the cause of death was asphyxia by compression. Toxicology found the presence of active and inactive cannabis metabolites in the decedent's blood. Recommendations/DiscussionTowing and recovery industry employers should instruct and ensure employees use a secondary means of support when placing any part of heir body under a raised vehicle.Part 1, General Provisions, Rule 34, of the General Industry Safety Standards states: "An employee shall not place his/her body beneath equipment, such as vehicles, machines, or materials, supported only by a jack, overhead hoist, chain fall, or any other temporary single supporting means, unless safety stands, blocks or other support system capable of supporting the total imposed weight is used to protect the employee in case of failure of the supporting system." The decedent relied upon the tow chains to hold the vehicle in position when he placed his torso under the vehicle to "pop" the transmission. When the chains failed to secure the vehicle in a raised position, there was not a secondary means to prevent the vehicle from falling onto him. It is important to note that when a secondary means of support is used on a vehicle, it must be placed under factory-approved points on the vehicle, as per the vehicle's instruction manual. Secondary supports such as safety stands or jack stands should always be used in pairs. When raising the front or rear of a vehicle the stands should not be placed so that the vehicle tilts up only on one corner. Blocking or chocking wheels is not a "means of support" and will not protect an individual under a raised vehicle, but blocking/chocking the wheels does prevent the tires from rolling. It is best to use two blocks/chocks on the weighted axle (the axle at the opposite end of the vehicle from the end that is raised), since the weighted axle keeps the tire on the ground against the block/chock.
|
||||||||||||
![]() |
||||||||||||
![]() |