CDC logoSafer Healthier People  CDC HomeCDC SearchCDC Health Topics A-Z
NIOSH - National Institute for Occupational Safety and Health

Skip navigation links Search NIOSH  |  NIOSH Home  |  NIOSH Topics  |  Site Index  |  Databases and Information Resources  |  NIOSH Products  |  Contact Us

 

NIOSH Pocket Guide to Chemical Hazards

September 2005

Ferrovanadium dust

CAS
12604-58-9

FeV

RTECS
LK2900000
Synonyms & Trade Names

Ferrovanadium
DOT ID & Guide

Exposure
Limits

NIOSH REL*: TWA 1 mg/m3 ST 3 mg/m3 [*Note: The REL also applies to Vanadium metal and Vanadium carbide.]
OSHA PEL†: TWA 1 mg/m3
IDLH
500 mg/m3 See: 12604589
Conversion
Physical Description
Dark, odorless particulate dispersed in air. [Note: Ferrovanadium metal is an alloy usually containing 50-80% vanadium.]
MW: 106.8
BP: ?
MLT: 2696-2768°F
Sol: Insoluble
VP: 0 mmHg (approx)
IP: NA

Sp.Gr: ?
Fl.P: NA
UEL: NA
LEL: NA
MEC: 1.3 g/m3
Metal: Noncombustible Solid, but dust may be an explosion hazard.
Incompatibilities & Reactivities

Strong oxidizers
Measurement Methods
OSHA ID121, ID125G
See: NMAM or OSHA Methods
Personal Protection & Sanitation
(See protection codes)
Skin: No recommendation
Eyes: No recommendation
Wash skin: No recommendation
Remove: No recommendation
Change: No recommendation

First Aid
(See procedures)
Eye: Irrigate immediately

Breathing: Respiratory support

Respirator Recommendations
NIOSH/OSHA
Up to 5 mg/m3:
(APF = 5) Any quarter-mask respirator. Click here for information on selection of N, R, or P filters.*
Up to 10 mg/m3:
(APF = 10) Any particulate respirator equipped with an N95, R95, or P95 filter (including N95, R95, and P95 filtering facepieces) except quarter-mask respirators. The following filters may also be used: N99, R99, P99, N100, R100, P100. Click here for information on selection of N, R, or P filters.*
(APF = 10) Any supplied-air respirator*
Up to 25 mg/m3:
(APF = 25) Any supplied-air respirator operated in a continuous-flow mode*
(APF = 25) Any powered air-purifying respirator with a high-efficiency particulate filter.*
Up to 50 mg/m3:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters.
(APF = 50) Any supplied-air respirator that has a tight-fitting facepiece and is operated in a continuous-flow mode*
(APF = 50) Any powered, air-purifying respirator with a tight-fitting facepiece and a high-efficiency particulate filter*
(APF = 50) Any self-contained breathing apparatus with a full facepiece
(APF = 50) Any supplied-air respirator with a full facepiece
Up to 500 mg/m3:
(APF = 2000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape:
(APF = 50) Any air-purifying, full-facepiece respirator with an N100, R100, or P100 filter. Click here for information on selection of N, R, or P filters./Any appropriate escape-type, self-contained breathing apparatus
Important additional information about respirator selection
Exposure Routes
inhalation, skin and/or eye contact
Symptoms
Irritation eyes, respiratory system; in animals: bronchitis, pneumonitis
Target Organs
Eyes, respiratory system
See also: INTRODUCTION   See MEDICAL TESTS: 0107

NIOSH Home
 |  NIOSH Search  | Site Index  | Topic List | Contact Us