Cruise Ship: Sapphire Princess Cruise line: Princess Cruises Inspection Date: 09/14/2004 Score: 98
 
This cruise ship inspection report lists the deficiencies found during the inspection. Additional information corresponding to each item number is available in the lastest editions of the CDC VSP Operational Manual.



 
Cruise Ship's Corrective Action Statement  |  View/Print Summary Report  |  View/Print Detail Report
 
 
Note: Click on the Item no. to view the item detail.
 
Item No.DescriptionPoints Deducted
03PW bunker / production source; Halogen residual0
08PW filling hoses, caps, connections, procedures; Sample records, valves; PW system constructed, maintained0
16Potentially hazardous food temperatures storage, preparation display, service, transportation0
19Food protected storage, preparation, display, service, transportation; Original containers, labeling; Food handling minimized; In-use food dispensing, preparation utensils stored0
20PHF temperature maintenance facilities; Food-contact surfaces designed, constructed, installed, maintained; TMD=s provided, located, calibrated2
27Equipment / utensils non-food-contact surfaces clean0
28Equipment / utensil / linen / single / service storage, handling, dispensed; Clean frequency0
33Decks / bulkheads / deckheads construction, repair, clean0
999Miscellaneous0
Selected Item Details
Item No.: 03
Site: Other-POTABLE WATER-PRODUCTION
Violation: ON A FEW DAYS SINCE THE LAST INSPECTION, THE HALOGEN ANALYZER RECORDER CHARTS FOR THE PRODUCTION OF POTABLE WATER SHOWED THE FREE CHLORINE RESIDUAL TO BE BELOW THE REQUIRED 2 PPM, WITHOUT CORRECTIVE ACTIONS DOCUMENTED.
Recommendation:5.2.1.1.1 Potable water shall be continuously halogenated to at least 2.0 mg/L (ppm) free residual halogen at the time of bunkering or production with an automatic halogenation device.
Site: Other-POTABLE WATER-BUNKERING
Violation: ON JUNE 30, 2004 THE HALOGEN ANALYZER RECORDER CHART FOR BUNKERING, RECORDED THE FREE CHLORINE RESIDUAL AT 1.5 PPM FOR MORE THAN 2 HOURS, WITHOUT CORRECTIVE ACTIONS DOCUMENTED.
Recommendation:5.2.1.1.1 Potable water shall be continuously halogenated to at least 2.0 mg/L (ppm) free residual halogen at the time of bunkering or production with an automatic halogenation device.