Item No. | Description | Points Deducted |
08 | PW filling hoses, caps, connections, procedures; Sample records, valves; PW system constructed, maintained | 1 |
10 | Swimming pools / spas maintained, safety equipment | 0 |
20 | PHF temperature maintenance facilities; Food-contact surfaces designed, constructed, installed, maintained; TMD=s provided, located, calibrated | 0 |
21 | Nonfood-contact surfaces designed, constructed, maintained, installed, located | 0 |
26 | Food-contact surfaces equipment / utensils clean; Safe | 0 |
27 | Equipment / utensils non-food-contact surfaces clean | 0 |
29 | Facilities convenient, accessible, designed, installed | 0 |
999 | Miscellaneous | 0 |
|
Selected Item Details
|
Item No.:
08
|
|
Site:
Other-POOLS AND WHIRLPOOLS |
Violation:
THE POTABLE WATER LINES IN THE TERRACE POOL PUMP ROOM WERE NOT STRIPED BLUE. |
Recommendation:5.3.2.1.1
Potable water piping shall be painted light blue or striped with 15 cm (6 inches) light blue bands or a light blue stripe at fittings on each side of partitions, decks, and bulkheads and at intervals not to exceed 5 m (15 feet) in all spaces, except where the decor would be marred by such markings. |
|
Site:
Other-POTABLE WATER |
Violation:
THERE WERE NUMEROUS DAYS WHEN THE FREE HALOGEN RESIDUAL TEST RESULTS WERE NOT RECORDED AT THE START OF PRODUCTION FOR THE POTABLE WATER SYSTEM. |
Recommendation:5.2.1.2.2