Home | About CDC | Press Room | A-Z Index | Contact Us
CDC Centers for Disease Control and Prevention Home Page
CDC en Español
 

Cruise Ship Inspection Details

  Basic Search |  Advanced Search |  Ship Scored 100 |  Green Sheet
 
Cruise Ship: Liberty of the Seas Cruise line: Royal Caribbean International Inspection Date: 09/29/2007 Score: 98
 
This cruise ship inspection report lists the deficiencies found during the inspection. Additional information corresponding to each item number is available in the lastest editions of the CDC VSP Operational Manual.



 
Cruise Ship's Corrective Action Statement  |  View/Print Summary Report  |  View/Print Detail Report
 
 
Note: Click on the Item no. to view the item detail.
 
Item No.DescriptionPoints Deducted
08PW filling hoses, caps, connections, procedures; Sample records, valves; PW system constructed, maintained0
10Swimming pools / spas maintained, safety equipment0
16Potentially hazardous food temperatures storage, preparation display, service, transportation0
17Temperature practices storage, preparation display, service, transportation; Thawing0
20PHF temperature maintenance facilities; Food-contact surfaces designed, constructed, installed, maintained; TMD=s provided, located, calibrated0
21Nonfood-contact surfaces designed, constructed, maintained, installed, located0
22Dishwashing / equipment washing facilities designed, constructed, maintained, installed, located, operated, TMDs, test kits2
28Equipment / utensil / linen / single / service storage, handling, dispensed; Clean frequency0
29Facilities convenient, accessible, designed, installed0
33Decks / bulkheads / deckheads construction, repair, clean0
34Plumbing fixtures / supply lines / drain lines / drains installed, repair0
37Rooms / equipment vented, humidity, condensation0
40IPM procedures developed; followed; outer openings protected0
Selected Item Details
Item No.: 08
Site: Galley-
Violation: The backflow preventer on the left combination oven was installed with the atmospheric vent pointing up.
Recommendation:Install the backflow preventer with the atmospheric vent pointing down.
Site: Pantry-Deck 11 Pool
Violation: The multiflow system backflow preventer between the carbonator and the brass fitting was steadily spitting water.
Recommendation:Ensure that backflow preventers are maintained in good repair.
Site: Galley-Deck 5 Room Service Pantry
Violation: The potable water line serving the coffee machines was not equipped with a backflow prevention device. A unit was installed at the time of the inspection.
Recommendation:Ensure that backflow preventers are installed when air gaps are impractical or when water under pressure is required.
*Inspections scores of 85 or lower are NOT satisfactory
Safer, Healthier People
Centers for Disease Control and Prevention, 1600 Clifton Rd, Atlanta, GA 30333, U.S.A
Tel: (404) 639-3311 / Public Inquiries: (404) 639-3534 / (800) 311-3435
FirstGov
DHHS
Department of Health
and Human Services