Cruise Ship: Norwegian Dawn Cruise line: Norwegian Cruise Lines Inspection Date: 03/10/2008 Score: 100
 
This cruise ship inspection report lists the deficiencies found during the inspection. Additional information corresponding to each item number is available in the lastest editions of the CDC VSP Operational Manual.



 
Cruise Ship's Corrective Action Statement  |  View/Print Summary Report  |  View/Print Detail Report
 
 
Note: Click on the Item no. to view the item detail.
 
Item No.DescriptionPoints Deducted
08PW filling hoses, caps, connections, procedures; Sample records, valves; PW system constructed, maintained0
16Potentially hazardous food temperatures storage, preparation display, service, transportation0
21Nonfood-contact surfaces designed, constructed, maintained, installed, located0
22Dishwashing / equipment washing facilities designed, constructed, maintained, installed, located, operated, TMDs, test kits0
27Equipment / utensils non-food-contact surfaces clean0
33Decks / bulkheads / deckheads construction, repair, clean0
34Plumbing fixtures / supply lines / drain lines / drains installed, repair0
38Unnecessary articles, cleaning equipment; Unauthorized personnel0
Selected Item Details
Item No.: 08
Site: Potable Water-Cross-Connection Control Program
Violation: The air gaps for the two ice machines in the pool bar pantry were not listed in the cross-connection control program.
Recommendation:Ensure that the cross-connection control program includes at minimum: a complete listing of cross-connections and the backflow prevention method/device for each, so that there is a match to the plumbing system component and location, and an inspection frequency. Ensure that air-gaps are included in the listing.
Site: Potable Water-Cross-Connection Control Program
Violation: The juice machines located in each of the four service line beverage stations were not fitted with backflow prevention devices.
Recommendation:Ensure that backflow preventers are installed when air gaps are impractical or when water under pressure is required.
Site: Potable Water-Cross-Connection Control Program
Violation: One of the spa pool showers did not have a backflow prevention device. The shower hose was long enough to allow the shower head to rest on the deck.
Recommendation:Install an appropriate backflow prevention device on the shower hose.
*Inspections scores of 85 or lower are NOT satisfactory