Item No. | Description | Points Deducted |
08 | PW filling hoses, caps, connections, procedures; Sample records, valves; PW system constructed, maintained | 0 |
10 | Swimming pools / spas maintained, safety equipment | 0 |
19 | Food protected storage, preparation, display, service, transportation; Original containers, labeling; Food handling minimized; In-use food dispensing, preparation utensils stored | 0 |
25 | Wiping cloths / chef=s towels clean, stored, used | 0 |
28 | Equipment / utensil / linen / single / service storage, handling, dispensed; Clean frequency | 0 |
29 | Facilities convenient, accessible, designed, installed | 0 |
33 | Decks / bulkheads / deckheads construction, repair, clean | 0 |
37 | Rooms / equipment vented, humidity, condensation | 0 |
41 | Child Activity Centers facilities, diaper changing, operation | 0 |
|
Selected Item Details
|
Item No.:
08
|
|
Site:
Other-Deck 4 Chemical Locker |
Violation:
It could not be determined a backflow prevention device was installed on the chemical dispenser. |
Recommendation:The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at any connection between potable and non-potable water systems. |
|
Site:
Potable Water-Cross-connection Control Program |
Violation:
The cross-connection control program did not include the chemical dispensers, the spa showers or the air gaps. This was corrected. |
Recommendation:Ensure that the cross-connection control program includes at minimum: a complete listing of cross-connections and the backflow prevention method/device for each, so that there is a match to the plumbing system component and location, and an inspection frequency. Ensure that air-gaps are included in the listing. |
|
|