![]() |
|
![]() |
Fatality Assessment and Control Evaluation (FACE) Program |
![]() |
12-Year-Old Farm Boy Dies While Hitching Up Hay Wagon | ![]() |
| |||||||||||
SummaryIn early summer 2004, a 12-year-old boy was killed while helping a farmer, his uncle, hitch a hay wagon to a truck. They had been baling hay the day before and, next morning, were preparing to unload the hay bales from the hay wagon/hayrack, which was parked in the farmyard (Photo 1). The farmer was driving a 1-ton flatbed truck, which he had just backed up to the front of the hay wagon. The boy jumped out of the truck to hitch up the wagon, and when he lifted the tongue on the wagon, the wagon apparently started to slowly roll forward toward the truck. The boy failed to get the tongue hitched to the rear of the truck, and the wagon continued its slow forward roll, pinching the boy’s head between the wagon and the rear of the truck’s metal bed. The farmer, sitting in the driver’s seat of the truck, felt nothing unusual. Suddenly, not seeing the boy, he jumped out and ran back to find him slumped over the tongue of the wagon, and a large pool of blood on the ground. The boy was dead at the scene. The tongue of the wagon had bulldozed into the ground, indicating that the wagon had moved forward (Photo 2).
Recommendations based on our investigation are as follows:
IntroductionDuring the summer of 2004, a 12-year-old farm boy was working for his uncle when he was crushed between a hay wagon and a truck bed. The Iowa FACE program was alerted to this incident by a colleague, and an immediate investigation was begun, gathering information from newspapers, the County Sheriff, and the State Medical Examiner’s Office. Contact was made with the farmer who owned the farm. However, a site visit was not conducted since excellent information and photographs were obtained from the county sheriff. The uncle was a farmer who managed 700 acres (285 hectares) of land planted in corn, soybeans, and hay. He had been working and living with his family at this location for the past 25 years. The boy was one of several neighbor boys who had worked at the man’s farm over the past several years. On the day of this incident, the farmer was also working with a neighbor and another 16-year-old boy, for a total work crew of four, baling hay early in the summer. There was no official safety program or written policies for employment at this small farm. Several local farm boys were frequently hired for odd jobs on an hourly basis, and paid in cash. The farmer had significant construction experience, and he would often hire 6 or 7 boys throughout the summer to assist with various farm and related construction projects.
Back to TopInvestigationOn the day prior to this incident, the work crew of four had baled about 800 bales of hay, using a conventional square baler, which creates bales that weigh about 40-60 lbs (18-27 kg). They had baled several loads of hay and, early the next morning, were in the process of moving this hay into storage. The 12-year-old boy was big and strong for his age, and could easily handle the hay bales. Nonetheless, the farmer would move bales stacked too high for the helper, and leave the lower bales for the boy, who was earning extra money to attend the county fair. The hay wagon was a typical wooden rack on a standard running gear with a metal tongue and clevis hitch (Photo 2). The wagon carried 100 bales of hay and was parked alone in the farmyard without brakes or wheel chocks. The edges of the hay rack bed were covered with 1½ in. angle iron (Photo 3). The farmer and boy worked approximately 30 minutes that morning before they drove to retrieve the loaded hay wagon. The farmer drove his 1-ton straight truck with flatbed box containing old pieces of plywood, a pallet, and several bags of soybean seed. The plywood stuck out beyond the truck bed about 12 inches (300 mm).
The loaded hay wagon had been moved into the farm yard the day before by the farmer and his wife. The farmer remembered pulling the hitch pin himself, and seeing the tongue fall to the ground without the wagon continuing to move. This area of the farmyard was flat (Photo 1), not at all like other areas of his farm ground, which required all wagons to be blocked against rolling. There was no indication that the loaded hay wagon might roll. The farmer backed his truck into position in front of the hay wagon and the boy jumped out to hitch up the wagon. This was a simple task he had done many times before. Looking into the side mirror, the farmer was communicating with the youth when he suddenly lost sight of him. Exact details at this point are hard for the farmer to recall, but he did not feel a collision of any kind. He immediately pulled his truck forward a few feet, then jumped out and ran behind to find the boy slumped over the tongue of the wagon, and a large pool of blood on the ground. There was approximately 4-5 feet between the vehicles at this time. According to the farmer, the boy hardly had a mark on him, but was not breathing. It was determined later that he had died instantly from a head injury. There was no damage to the truck or the hay wagon, or any signs of direct collision of the two vehicles. Measurements taken at the scene showed the front of the loaded hay wagon at 35--36½ inches (890-930mm) above the ground, and the rear of the flat bed truck at 34¾--39 inches (880-990 mm) above the ground (Diagram 1). Given these measurements, and the description by the farmer, it is possible the hay wagon slowly rolled just close enough towards the rear of the truck, but without touching it, to fatally injure the boy as he bent over the wagon tongue to guide it toward the pickup’s hitch and drop the hitch-pin in place. Once pushed, bumped, or rocked back in the tracks into which it had settled, been pulled, or otherwise set in motion, even a slow-moving wagon can be difficult to stop.
Back to TopCause of DeathThe cause of death from the medical Examiner’s report was, “neurogenic shock due to acute cranial cerebral blunt force trauma due to a farm accident.” Recommendations/DiscussionRecommendation #1: Farm wagons without parking brakes should always have their wheels chocked to prevent them from rolling, especially when parked on rolling or sloping ground.Discussion: The farmer assumed that the area of his farmyard in Photo 1 was flat. While it appears flat in the photograph, the terrain under the wagon apparently sloped slightly away from the front of the wagon, as evidenced by the tongue, which was found dug into the dirt after the wagon had rolled (Photo 2). On ground that was obviously sloped, the farmer always used wheel chocks, but he never considered them at this location because of the flat appearance of the terrain. When the wagon was unhitched and left in position, the tongue would have dropped to the ground and dug in slightly if the wagon had continued to move from its own momentum. However, the wagon did not appear to have moved appreciably, and the farmer may have assumed it to be stable and at rest on flat ground, even though there may have been a forward push on the tongue. The direction of the forces on this wagon could have changed while the wagon sat overnight in the farmyard as the wheels settled into the ground. It is possible that, initially, the tongue was holding the wagon in place, and when the boy picked it up, the wagon began to move. Experienced farmers in this situation would typically lean against the wagon to slow or stop it before it struck the truck, stick the tongue back in the dirt as a temporary stop, or jump out of the way if the wagon continued to roll. A less experienced 12-year-old boy may not know these techniques or be able to employ them. The seemingly simple job of hooking up a wagon evidently became a complex maneuver of trying to manage the moving tongue of the hay wagon with one hand, and working with a hitch pin in the other hand, hoping they would somehow come together with the wagon properly hitched to the truck. Leaving farm wagons un-chocked is somewhat like parking a motor vehicle with its manual transmission in neutral without engaging the parking brake, something that is rarely done for fear the vehicle might roll away. Wheel chocks should be regular equipment for all farm wagons and other vehicles which do not have built-in parking brakes. Farmers should develop a habit of using them on a regular basis even on “flat ground”, remembering the tragic consequences evident in this case. On ground that is obviously sloped, one should block all four wheels against movement with substantial chocks or other means to guarantee the wagon will stay put.
|